Sealed Types
B3W Tactile Switch (Sealed Type)
Allows Cleaning After Soldering with Alcohol Solvents
- Internal sealed construction allows immersion cleaning with alcohol solvents after soldering.
- Thin, compact construction in both 12 × 12 mm and 6 × 6 mm sizes.
- Snap-action contact construction for a positive click action.
- Available with ground terminals for protection against static electricity.
- Sealed construction also provides high reliability in dusty environments.
|
|
| Type |
Plunger |
Height |
Operating force (OF) |
Bags (100 Switches) |
| Without ground terminal |
With ground terminal |
| 6 × 6 mm B3W-1000 |
Flat type
|
4.3mm |
Standard force |
1.57 N {160 gf} |
B3W-1000 |
B3W-1100 |
| High-force |
2.25 N {230 gf} |
B3W-1002 |
B3W-1102 |
| Projected type
 |
7.3mm |
Standard force |
1.57 N {160 gf} |
B3W-1050 |
B3W-1150 |
| High-force |
2.25 N {230 gf} |
B3W-1052 |
B3W-1152 |
| 12× 12 mm B3W-4000 |
Flat type
 |
4.3mm |
Standard force |
1.96 N {200 gf} |
B3W-4000 |
B3W-4100 |
| High-force |
3.43 N {350 gf} |
B3W-4005 |
B3W-4105 |
| Projected type
 |
7.3mm |
Standard force |
1.96 N {200 gf} |
B3W-4050 |
B3W-4150 |
| High-force |
3.43 N {350 gf} |
B3W-4055 |
B3W-4155 |
Note: Orders must be made in units of 100 pieces (quantity per bag).
| Switching capacity |
1 to 50 mA, 5 to 24 VDC
(resistive load) |
| Ambient temperature |
-25ºC to 70ºC (with no
icing) |
| Ambient humidity |
35% to 85% |
| Contact configuration |
SPST-NO |
| Contact resistance |
100 mΩ max. (initial
value) (rated: 1 mA,
5 VDC) |
| Insulation resistance |
100 MΩ min. (at 250 VDC) |
| Dielectric strength |
500 VAC, 50/60 Hz for
1 min |
| Bounce time |
5 ms max. |
| Vibration resistance |
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude |
| Shock resistance |
| Destruction: |
1,000 m/s2 {approx. 100 G} max. |
| Malfunction: |
100 m/s2 {approx. 10 G} max. |
|
| Life expectancy |
B3W-1000:
| |
1.57 N (standard force):1,000,000 operations
min. |
| |
2.26 N (high-force):300,000 operations min. |
B3W-4000:
| |
1.96 N (standard force):3,000,000 operations min. |
| |
3.43 N (high-force):1,000,000 operations min. |
|
| Weight |
6 × 6 mm: approx. 0.3 g, 12 × 12: approx. 1 g |
Operating Characteristics
| |
B3W-1000 |
B3W-4000 |
| 1.57N |
2.26N |
1.96N |
3.43N |
Operating force(OF) |
1.57N {160 gf} max. |
2.26N {230 gf} max. |
1.96N {200 gf} max. |
3.43N {350 gf} max. |
Releasing force (RF) |
0.2N {20gf} min. |
0.49 {50 gf} min. |
0.29N {30 gf} min. |
0.49N {50 gf} min. |
| Pretravel (PT) |
0.25+0.2/-0.1mm |
0.3+0.2/-0.1mm |
| Note:1. |
All units are in millimeters unless otherwise indicated. Unless otherwise
specified, a tolerance of ±0.4 mm applies to all dimensions. |
| 2. |
No
terminal numbers are indicated on the Switches. The numbers used for terminals
in the following graphics are indicated in the "Bottom
View" diagram below. In this diagram, the Switch is rotated so that
the terminals are on the right and left-hand sides, and the OMRON logo
appears the right way up. |
|
|
| Flat Plunger Type (without Ground Terminal) |
B3W-1000 B3W-1002 |
 |
|
|
Flat Plunger Type (with Ground Terminal) |
B3W-1100 B3W-1102 |
 |
|
|
Projected Plunger Type (without Ground Terminal) |
B3W-1050 B3W-1052 |
 |
|
|
Projected Plunger Type (with Ground Terminal) |
B3W-1150 B3W-1152 |
 |
|
|
|
|
| Flat Plunger Type (without Ground Terminal) |
B3W-4000 B3W-4005 |
 |
|
|
Flat Plunger Type (with Ground Terminal) |
B3W-4100 B3W-4105 |
 |
|
|
Projected Plunger Type (without Ground Terminal) |
B3W-4050 B3W-4055 |
 |
|
Projected Plunger Type (with Ground Terminal) |
B3W-4150 B3W-4155 |
 |
|
Precautions Be sure to refer to Safety Precautions on proper use.  |
|
Switches
Products Lineup
Relational Contents
Contact Us
|