A8L Miniature Rocker Switch

Rocker Switch for High Current Switching

  • Withstands inrush currents up to 100 A due to a unique switching mechanism.
  • Soft touch with firm switching action.
  • Easy to mount by snap fitting.
  • Contact gap of 3 mm minimum.
  • UL and cUL standards approved. Conforms to EN standards.
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Color of caps and cases (flanges) Marking on caps
SPST
img
Solder terminals PCB terminals Rightangled PCB terminals Leftangled PCB terminals Quickconnect terminals #187
Black Without
markings
A8L-11-11N1 A8L-11-12N1 A8L-11-13N1 A8L-11-14N1 A8L-11-15N1
img A8L-11-11N2 A8L-11-12N2 A8L-11-13N2 A8L-11-14N2 A8L-11-15N2

Color of caps and cases (flanges) Marking on caps
DPST
img
Solder terminals PCB terminals Rightangled PCB terminals Leftangled PCB terminals Quickconnect terminals #187
Black Without
markings
A8L-21-11N1 A8L-21-12N1 A8L-21-13N1 A8L-21-14N1 A8L-21-15N1
img A8L-21-11N2 A8L-21-12N2 A8L-21-13N2 A8L-21-14N2 A8L-21-15N2

OrderingInformationRatings / CharacteristicsDimensions
Specifications
Ratings
Rated load Non-inductive Inductive
Resistive load Lamp load Inductive load Inductive motor load
125 VAC 10 A 10 A 8 A 8 A
250 VAC 10 A 10 A 8 A 8 A
Note: 1. The non-inductive lamp load has an impulse current ten times the normal current.
2. The inductive load has a power factor of 0.4 minimum (AC).
3. The motor load has an impulse current 6 times the normal current.
The above ratings were tested under the following conditions:
  1. Ambient temperature:20 ±2ºC
  2. Ambient humidity:65% ±5%
  3. Switching frequency:7 times/min

Characteristics
Permissible operating frequency
Mechanical: 20 operations/min max.
Electrical: 7 operations/min max.
Insulation resistance 100 MΩmin. (500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz, for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz, for 1 min between terminals of the different polarity
4,000 VAC, 50/60 Hz, for 1 min between charged metal parts and the ground terminal
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (malfunction time of 1 ms max.)
Shock resistance
Malfunction: 300 m/s2 (malfunction time of 1 ms max.)
Destruction: 500 m/s2
Life expectancy
Mechanical: 50,000 operations min.
Electrical: 10,000 operations min.
Inrush current 100 A max. (8.3 ms max.)
Ambient temperature
Operating: -20 to 55 ºC (with no icing or condensation)
Storage: -25 to 60 ºC (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Storage: 45% to 85%
Note:   Consult your OMRON representative for details of performance characteristics with respect to individual standards.
OrderingInformationRatings / CharacteristicsDimensions
Note: All units are in millimeters unless otherwise indicated.
Solder Terminals A8L:Dimensions1
A8L-11-11N1
A8L-11-11N2
A8L-21-11N1
A8L-21-11N2
img
No. of poles
1
2
OF (operating force)
2.16±1.18N 3.92±2.45N
Note: All units are in millimeters unless otherwise indicated.
PCB Terminals A8L:Dimensions2
A8L-11-12N1
A8L-11-12N2
A8L-21-12N1
A8L-21-12N2
img
No. of poles
1
2
OF (operating force)
2.16±1.18N 3.92±2.45N
Right-angled PCB Terminals A8L:Dimensions3
A8L-11-13N1
A8L-11-13N2
A8L-21-13N1
A8L-21-13N2
img
No. of poles
1
2
OF (operating force)
± ±

Left-angled PCB Terminals A8L:Dimensions4
A8L-11-14N1
A8L-11-14N2
A8L-21-14N1
A8L-21-14N2
img
No. of poles
1
2
OF (operating force)
± ±
Quick-connect Terminals #187 A8L:Dimensions5
 
img
No. of poles
1
2
OF (operating force)
± ±