Rocker Switches
A8G Reset Rocker Switch
Rocker Switch with External Reset Function for High capacity Switching
- Energy-saving reset function triggered with external signals.
- Incorporates unique switching mechanism switching 20 A with excellent inrush-current durability.
- Double-pole, double-throw (DPDT) contact.
- Contact gap of 3 mm minimum.
- UL and cUL standard approved. Conforms to EN standards.
 |
|
|
|
|
|
Updated October 24, 2011
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
List of Models
| Contact Form |
DPDT
 |
Quantity per box |
| Color of cases |
Black |
50 |
| Cap color |
Black
|
| Model |
A8G-107-1-24 |
Ratings
| Rated load |
Non-inductive |
Inductive |
| Resistive load |
Lamp load |
Inductive load |
Motor load |
| 250 VAC |
20A |
10A |
8A |
8A |
| Note: |
1. |
The non-inductive lamp load has an inrush current 10 times steady current. |
|
2. |
The inductive load has a power factor of 0.4 minimum (AC). |
|
3. |
The motor load has an inrush current 6 times steady current.
The above ratings were tested under the following conditions:
1. Ambient temperature: 20±2 °C
2. Ambient humidity: 65±5 %RH
3. Switching frequency: 7 times/min. |
Reset Coil
Rated voltage
(operating voltage range) |
Reset voltage
(coil temperature:
20°C±2°C) |
Rated energized current
(coil temperature:
20°C±2°C) |
Coil resistance
(coil temperature:
20°C±2°C) |
Permissible voltage
applied period |
24 VDC±10%
(21.6 to 26.4 VDC) |
21.6 V max. |
185 mA±20% |
130 Ω±20% |
100 ms for min 1 s max. |
| Note: |
1. |
Current must not flow for more than 10 s, otherwise the performance of the coil may be affected. |
|
2. |
If a semiconductor element is used to control the reset coil, the residual voltage caused by leakage current must be 2.4 VDC max. |
Characteristics
Permissible operating frequency
|
Mechanical: Switching frequency: 7 times/min.; Coil operation: 7 times/min.
Electrical: 20 operations/min max. |
| Insulation resistance |
100 MΩ min. (500 VDC) |
| Dielectric strength |
2,000 VAC, 50/60 Hz, for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz, for 1 min between terminals of the different polarity
4,000 VAC, 50/60 Hz, for 1 min between charged metal parts and the ground terminal |
| Vibration resistance |
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude |
| Shock resistance |
Malfunction: 98 m/s2 (10G)
Destruction: 500 m/s2 (50G) max. |
| Durability |
Mechanical: Switching operation 100,000 times min.
Electrical: Switching operation 50,000 times min. |
Contact release time
(see note) |
100 ms max. |
| Ambient operating temperature |
-10 to +55 °C (with no icing or condensation) |
| Ambient operating humidity |
45 to 85 %RH |
| Note: |
|
For the codition in individual standard, contact your OMRON sales representative.
Contact release time is the period of time during which contacts 1 and 2 and contacts 4 and 5 are released after voltage is imposed on the coil. |
Note: All units are in millimeters unless otherwise indicated.
A8G
Operating Characteristics
| Operating force (OF) max. |
19.6 N {2,000 gf} |
|
Switches
Product Lineup
Support