Rocker Switches
A8L Miniature Rocker Switch
Rocker Switch for High Current Switching
- Withstands inrush currents up to 100 A due to a unique switching mechanism.
- Soft touch with firm switching action.
- Easy to mount by snap fitting.
- Contact gap of 3 mm minimum.
- UL and cUL standards approved. Conforms to EN standards.
|
|
| Color of caps and cases (flanges) |
Marking on caps |
| SPST |
 |
|
| Solder terminals |
PCB terminals |
Rightangled PCB terminals |
Leftangled PCB terminals |
Quickconnect terminals #187 |
| Black |
Without markings |
A8L-11-11N1 |
A8L-11-12N1 |
A8L-11-13N1 |
A8L-11-14N1 |
A8L-11-15N1 |
 |
A8L-11-11N2 |
A8L-11-12N2 |
A8L-11-13N2 |
A8L-11-14N2 |
A8L-11-15N2 |
| Color of caps and cases (flanges) |
Marking on caps |
| DPST |
 |
|
| Solder terminals |
PCB terminals |
Rightangled PCB terminals |
Leftangled PCB terminals |
Quickconnect terminals #187 |
| Black |
Without markings |
A8L-21-11N1 |
A8L-21-12N1 |
A8L-21-13N1 |
A8L-21-14N1 |
A8L-21-15N1 |
 |
A8L-21-11N2 |
A8L-21-12N2 |
A8L-21-13N2 |
A8L-21-14N2 |
A8L-21-15N2 |
Specifications
Ratings
| Rated load |
Non-inductive |
Inductive |
| Resistive load |
Lamp load |
Inductive load |
Inductive motor load |
| 125 VAC |
10 A |
10 A |
8 A |
8 A |
| 250 VAC |
10 A |
10 A |
8 A |
8 A |
| Note: |
1. |
The non-inductive lamp load has an impulse current ten times the normal current. |
|
2. |
The inductive load has a power factor of 0.4 minimum (AC). |
|
3. |
The motor load has an impulse current 6 times the normal current. |
| The above ratings were tested under the following conditions: |
| |
1. |
Ambient temperature:20 ±2ºC |
| |
2. |
Ambient humidity:65% ±5% |
| |
3. |
Switching frequency:7 times/min |
Characteristics
| Permissible operating frequency |
| Mechanical: |
20 operations/min max. |
| Electrical: |
7 operations/min max. |
|
| Insulation resistance |
100 MΩmin. (500 VDC) |
| Dielectric strength |
2,000 VAC, 50/60 Hz, for 1 min between terminals of the same polarity 2,000 VAC, 50/60 Hz, for 1 min between terminals of the different polarity 4,000 VAC, 50/60 Hz, for 1 min between charged metal parts and the ground terminal |
| Vibration resistance |
| Malfunction: |
10 to 55 Hz, 1.5-mm double amplitude (malfunction time of 1 ms max.) |
|
| Shock resistance |
| Malfunction: |
300 m/s2 (malfunction time of 1 ms max.) |
| Destruction: |
500 m/s2 |
|
| Life expectancy |
| Mechanical: |
50,000 operations min. |
| Electrical: |
10,000 operations min. |
|
| Inrush current |
100 A max. (8.3 ms max.) |
| Ambient temperature |
| Operating: |
-20 to 55 ºC (with no icing or condensation) |
| Storage: |
-25 to 60 ºC (with no icing or condensation) |
|
| Ambient humidity |
| Operating: |
45% to 85% |
| Storage: |
45% to 85% |
|
| Note: |
|
Consult your OMRON representative for details of performance characteristics with respect to individual standards. |
| Note: |
All units are in millimeters unless otherwise indicated. |
| Solder Terminals |
 |
A8L-11-11N1
A8L-11-11N2
A8L-21-11N1
A8L-21-11N2
|
 |
 |
| |
1 |
2 |
| |
2.16±1.18N |
3.92±2.45N |
| Note: |
All units are in millimeters unless otherwise indicated. |
| PCB Terminals |
 |
A8L-11-12N1 A8L-11-12N2 A8L-21-12N1 A8L-21-12N2 |
 |
 |
| |
1 |
2 |
| |
2.16±1.18N |
3.92±2.45N |
|
| Right-angled PCB Terminals |
 |
A8L-11-13N1 A8L-11-13N2 A8L-21-13N1 A8L-21-13N2 |
 |
 |
|
| Left-angled PCB Terminals |
 |
A8L-11-14N1 A8L-11-14N2 A8L-21-14N1 A8L-21-14N2 |
 |
 |
|
| Quick-connect Terminals #187 |
 |
| |
 |
 |
|
|
Switches
Products Lineup
Relational Contents
Contact Us
|