Relays
Sensors
Optical Communication Devices
Wireless & High Frequency Devices
By Name
By Category
Switches
Micro Sensing Devices
Foundry
Connectors
Touch Sensors
Face Recognition Sensor

Rocker Switches

Search by product list
A8L Miniature Rocker Switch
Rocker Switch for High Current Switching
  • Withstands inrush currents up to 100 A due to a unique switching mechanism.
  • Soft touch with firm switching action.
  • Easy to mount by snap fitting.
  • Contact gap of 3 mm minimum.
  • UL and cUL standards approved. Conforms to EN standards.
XF2C
JPN
2D3D
OrderingInformationRatings / CharacteristicsDimensions
Color of caps and cases (flanges) Marking on caps
SPST
img
Solder terminals PCB terminals Rightangled PCB terminals Leftangled PCB terminals Quickconnect terminals #187
Black Without
markings
A8L-11-11N1 A8L-11-12N1 A8L-11-13N1 A8L-11-14N1 A8L-11-15N1
img A8L-11-11N2 A8L-11-12N2 A8L-11-13N2 A8L-11-14N2 A8L-11-15N2

Color of caps and cases (flanges) Marking on caps
DPST
img
Solder terminals PCB terminals Rightangled PCB terminals Leftangled PCB terminals Quickconnect terminals #187
Black Without
markings
A8L-21-11N1 A8L-21-12N1 A8L-21-13N1 A8L-21-14N1 A8L-21-15N1
img A8L-21-11N2 A8L-21-12N2 A8L-21-13N2 A8L-21-14N2 A8L-21-15N2

OrderingInformationRatings / CharacteristicsDimensions
Specifications
Ratings
Rated load Non-inductive Inductive
Resistive load Lamp load Inductive load Inductive motor load
125 VAC 10 A 10 A 8 A 8 A
250 VAC 10 A 10 A 8 A 8 A
Note: 1. The non-inductive lamp load has an impulse current ten times the normal current.
2. The inductive load has a power factor of 0.4 minimum (AC).
3. The motor load has an impulse current 6 times the normal current.
The above ratings were tested under the following conditions:
  1. Ambient temperature:20 ±2ºC
  2. Ambient humidity:65% ±5%
  3. Switching frequency:7 times/min

Characteristics
Permissible operating frequency
Mechanical: 20 operations/min max.
Electrical: 7 operations/min max.
Insulation resistance 100 MΩmin. (500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz, for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz, for 1 min between terminals of the different polarity
4,000 VAC, 50/60 Hz, for 1 min between charged metal parts and the ground terminal
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (malfunction time of 1 ms max.)
Shock resistance
Malfunction: 300 m/s2 (malfunction time of 1 ms max.)
Destruction: 500 m/s2
Life expectancy
Mechanical: 50,000 operations min.
Electrical: 10,000 operations min.
Inrush current 100 A max. (8.3 ms max.)
Ambient temperature
Operating: -20 to 55 ºC (with no icing or condensation)
Storage: -25 to 60 ºC (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Storage: 45% to 85%
Note:   Consult your OMRON representative for details of performance characteristics with respect to individual standards.
OrderingInformationRatings / CharacteristicsDimensions
Note: All units are in millimeters unless otherwise indicated.
Solder Terminals A8L:Dimensions1
A8L-11-11N1
A8L-11-11N2
A8L-21-11N1
A8L-21-11N2
img
No. of poles
1
2
OF (operating force)
2.16±1.18N 3.92±2.45N
Note: All units are in millimeters unless otherwise indicated.
PCB Terminals A8L:Dimensions2
A8L-11-12N1
A8L-11-12N2
A8L-21-12N1
A8L-21-12N2
img
No. of poles
1
2
OF (operating force)
2.16±1.18N 3.92±2.45N
Right-angled PCB Terminals A8L:Dimensions3
A8L-11-13N1
A8L-11-13N2
A8L-21-13N1
A8L-21-13N2
img
No. of poles
1
2
OF (operating force)
± ±

Left-angled PCB Terminals A8L:Dimensions4
A8L-11-14N1
A8L-11-14N2
A8L-21-14N1
A8L-21-14N2
img
No. of poles
1
2
OF (operating force)
± ±
Quick-connect Terminals #187 A8L:Dimensions5
 
img
No. of poles
1
2
OF (operating force)
± ±