Rocker Switches
A8G Reset Rocker Switch
Rocker Switch with Reset Function for High Current Switching
- Energy-saving reset function triggered with external signals.
- Incorporates unique switching mechanism switching 20 A with excellent inrush-current durability.
- Double-pole, double-throw (DPDT) contact.
- Contact gap of 3 mm minimum.
- Approved by UL, cUL, and IEC.
- Bears the CE marking.
|
|
| Item |
A8G-107-1-24 |
| Contact configuration |
DPDT
 |
| Flange color (case) |
Black |
| Cap color |
Black |
Ratings Contact
| Rated load |
Non-inductive resistive load: |
20 A at 250 VAC |
| Non-inductive lamp load: |
10 A at 250 VAC |
| Inductive load: |
8 A at 250 VAC |
| Inductive motor load: |
8 A at 250 VAC |
| Note: |
1. |
The non-inductive lamp load has an impulse current ten times the normal current. |
|
2. |
The inductive load has a power factor of 0.4 minimum (AC). |
|
3. |
The motor load has an impulse current 6 times the normal current. |
| The above ratings were tested under the following conditions: |
| |
1. |
Ambient temperature:20 ±2ºC |
| |
2. |
Ambient humidity:65% ±5% |
| |
3. |
Switching frequency:7 times/min |
Reset Coil
| Rated voltage
(operating voltage
range) |
Reset voltage
(coil temperature:
20ºC ±2ºC) |
Rated energized current
(coil temperature:
20ºC ±2ºC) |
Coil resistance
(coil temperature:
20ºC ±2ºC) |
Permissible voltage
applied period |
24 VDC±10% (21.6 to 26.4 VDC) |
21.6 V max. |
185 mA±20% |
130 Ω±20% |
100 ms to 1 s |
| Note: |
1. |
Current must not flow for more than 10 s, otherwise the performance of the coil may be affected. |
|
2. |
If a semiconductor element is used to control the reset coil, the residual voltage caused by leakage current must be 2.4 VDC max. |
Characteristics
| Permissible operating speed |
1 to 500 mm/s |
| Permissible operating frequency |
| Mechanical: |
Switching frequency: 7 times/min.; Coil operation: 7 times/min |
| Electrical: |
20 operations/min max. |
|
| Insulation resistance |
100 MΩ min. (500 VDC) |
| Dielectric strength |
2,000 VAC, 50/60 Hz, for 1 min between terminals of the same polarity 2,000 VAC, 50/60 Hz, for 1 min between terminals of the different polarity 4,000 VAC, 50/60 Hz, for 1 min between charged metal parts and the ground terminal |
| Vibration resistance |
| Malfunction: |
10 to 55 Hz, 1.5-mm double amplitude (with a contact separation time of 1 ms max.) |
|
| Shock resistance |
| Malfunction: |
98 m/s2(10G) (with a contact separation time of 1 ms max.) |
| Destruction: |
500 m/s2 (50G) max. |
|
| Life expectancy |
| Mechanical: |
Switching operation: 50,000 times min.; Coil operation: 10,000 times min. |
| Electrical: |
Switching operation: 100,000 times min.; Coil operation: 10,000 times min. |
|
| Contact release time (see note) |
100 ms max. |
| Ambient temperature |
| Operating: |
-10ºCC to 55ºC(with no icing or condensation) |
| Storage: |
-25ºC to 60ºC (with no icing or condensation) |
|
| Ambient humidity |
| Operating: |
45% to 85% |
| Storage: |
45% to 85% |
|
| Note: |
|
Contact release time is the period of time during which contacts 1 and 2 and contacts 4 and 5 are released after voltage is imposed on the coil. |
| Note: |
All units are in millimeters unless otherwise indicated. |
|
 |
| A8G |
 |
Operating Characteristics
| OF (operating force) |
19.6 N (2,000 gf) |
|
Switches