Change Text Size
A Wide Range of Models:
6 × 6 mm, 12 × 12 mm, Side-operated,
High-force, and Gold-plated.
Updated Aug. 31, 2012
This web page provides an excerpt from a datasheet. Refer to
Datasheet and other applicable documents for more information.
| Type | Plunger | Height | Operating force (OF) | Plunger color | Bags (in units of 100 Switches) | |
|---|---|---|---|---|---|---|
| Without ground terminal | With ground terminal | |||||
| Standard (B3F-1000) |
Flat type |
4.3mm | 0.98 N {100 gf} | lvory |
B3F-1000 | B3F-1100 |
| 1.47 N {150 gf} | Yellow | B3F-1002 | B3F-1102 | |||
| 2.55 N {260 gf} | Orange | B3F-1005 | B3F-1105 | |||
| 4.9 N {500 gf} | Red | B3F-1006 | - | |||
| 5.0mm | 0.98 N {100 gf} | Black | B3F-1020 | B3F-1120 | ||
| 1.47 N {150 gf} | Gray | B3F-1022 | B3F-1122 | |||
| 2.55 N {260 gf} | Pink | B3F-1025 | B3F-1125 | |||
| 4.9 N {500 gf} | Blue | B3F-1026 | - | |||
| 5.0 mm (7.5-mm pitch) | 0.98 N {100 gf} | Black | - | B3F-1110 | ||
| 7.0mm | 0.98 N {100 gf} | Black | B3F-1060 | - | ||
| 1.47 N {150 gf} | Yellow | B3F-1062 | - | |||
| 9.5mm | 0.98 N {100 gf} | Black | B3F-1070 | - | ||
| 1.47 N {150 gf} | Yellow | B3F-1072 | - | |||
| 2.55 N {260 gf} | Orange | B3F-1075 | - | |||
| Projected type |
7.3mm | 0.98 N {100 gf} | lvory | B3F-1050 | B3F-1150 | |
| 1.47 N {150 gf} | Yellow | B3F-1052 | B3F-1152 | |||
| 2.55 N {260 gf} | Orange | B3F-1055 | B3F-1155 | |||
| 4.9 N {500 gf} | Red | B3F-1056 | - | |||
| Side-operated (B3F-3000) |
Flat type |
3.15mm | 0.98 N {100 gf} | lvory | - | B3F-3100 |
| 1.47 N {150 gf} | Yellow | - | B3F-3102 | |||
| 2.55 N {260 gf} | Orange | - | B3F-3105 | |||
| 3.85mm | 0.98 N {100 gf} | Black | - | B3F-3120 | ||
| 1.47 N {150 gf} | Gray | - | B3F-3122 | |||
| 2.55 N {260 gf} | Pink | - | B3F-3125 | |||
| Projected type |
6.15mm | 0.98 N {100 gf} | lvory | - | B3F-3150 | |
| 1.47 N {150 gf} | Yellow | - | B3F-3152 | |||
| 2.55 N {260 gf} | Orange | - | B3F-3155 | |||
| High reliability gold-plated contact |
Flat type |
4.3 mm | 1.76 N {180 gf} | Yellow |
B3F-1002-G | B3F-1102-G |
| 5.0 mm | Gray | B3F-1022-G | B3F-1122-G | |||
| 7.0 mm | Yellow | B3F-1062-G (see note) |
- | |||
| 9.5 mm | Yellow | B3F-1072-G (see note) |
- | |||
| Projected type |
7.3 mm | Yellow | B3F-1052-G | - | ||
| Flat type |
3.85 mm | Gray | - | B3F-3122-G (see note) |
||
| Type | Plunger (or LED color) |
Height | Operating force (OF) | Plunger color | Bags (in units of 100 Switches) | |
|---|---|---|---|---|---|---|
| Without ground terminal | With ground terminal | |||||
| Standard (B3F-4000) |
Flat type | 4.3mm | 1.27 N {130 gf} | lvory | B3F-4000 | B3F-4100 |
| 2.55 N {260 gf} | Yellow | B3F-4005 | B3F-4105 | |||
| Projected type | 7.3mm | 1.27 N {130 gf} | lvory | B3F-4050 | B3F-4150 | |
| 2.55 N {260 gf} | Yellow | B3F-4055 | B3F-4155 | |||
| Long durability (B3F-5000) |
Flat type | 4.3mm | 1.27 N {130 gf} | Blue | B3F-5000 | B3F-5100 |
| Projected type | 7.3mm | Blue | B3F-5050 | B3F-5150 | ||
| High reliability gold-plated (B3F-5001) |
Flat type | 4.3mm | 1.27 N {130 gf} | Blue | B3F-5001 | B3F-5101 |
| Projected type | 7.3mm | Blue | B3F-5051 | B3F-5151 | ||
| Type | Plunger | Height | Operating force (OF) |
Plunger color | Taped Radial (1000 Switches) | |
|---|---|---|---|---|---|---|
| Without ground terminal |
With ground terminal |
|||||
| Taped Radial (B3F-6000) |
Flat type | 4.3mm | 0.98 N {100 gf} | lvory | B3F-6000 | B3F-6100 |
| 1.47 N {150 gf} | Yellow | B3F-6002 | B3F-6102 | |||
| 5.0mm |
0.98 N {100 gf} |
Black | B3F-6020 | B3F-6120 | ||
| 1.47 N {150 gf} |
Gray | B3F-6022 | B3F-6122 | |||
| Projected type |
7.3mm |
0.98 N {100 gf} |
lvory | B3F-6050 | B3F-6150 | |
| 1.47 N {150 gf} |
Yellow | B3F-6052 | B3F-6152 | |||
| Ratings | 1 to 50 mA, 5 to 24 VDC (resistive load) (B3F-G: 100 μA to 50 mA, 5 to 24 VDC) |
|---|---|
| Ambient operating temperature | -25°C to +70°C at 60%RH max. (with no icing or condensation) |
| Ambient operating humidity | 35% to 85% (at +5 to +35°C) |
| Contact form | SPST-NO |
| Contact resistance | 100 mΩ max. (initial value) (rated: 1 mA, 5 VDC) B3F-G: (rated: 100 μA, 5 VDC) |
| Insulation resistance | 100 MΩ min. (at 250 VDC) |
| Dielectric strength | 500 VAC, 50/60 Hz for 1 min |
| Bounce time | 5 ms max. |
| Vibration resistance | Malfunction: 10 to 55 Hz, 1.5 mm double amplitude |
| Shock resistance | Destruction: 1,000 m/s2 {approx. 100G} max. Malfunction: 100 m/s2 {approx. 10G} max. |
| Durability | B3F-1000, B3F-3000, B3F-6000: 1,000,000 operations min (OF: 0.98 N {100 gf}) (B3F-1070: 500,000 operations min) 300,000 operations min (OF: 1.47 N {150 gf}) 100,000 operations min (OF: 2.55 N {260 gf}) 50,000 operations min (OF: 4.9 N {500 gf}) B3F-4000: 3,000,000 operations min (OF: 1.27 N {131 gf}) 1,000,000 operations min (OF: 2.55 N {260 gf}) B3F-5000: 10,000,000 operations min. B3F-G: 300,000 operations min. |
Weight |
6 × 6 mm models: approx. 0.25 g 12 × 12 mm models (standard types): approx. 0.85 g Radial models: approx. 0.25 g |
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
|
B3F-1000, B3F-3000, B3F-6000 | B3F-4000, B3F-5000 | B3F-G | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.98N |
1.47N |
2.55N |
4.9N |
1.27N |
2.55N |
1.76 N | |||||||||||||
| B3F-1 B3F-3 B3F-6 |
B3F-1 B3F-3 B3F-6 |
B3F-1 B3F-3 |
B3F -10 |
B3F-4 B3F-5 B3F-5 |
B3F -4 |
B3F-1 B3F-3 |
|||||||||||||
| Operating force (OF) |
0.98±0.29N {100±30 gf} |
1.47±0.49N {150±50 gf} |
2.55±0.69N {260±70 gf} |
4.9±1.47 N {500±150 gf} |
1.27±0.49N {130±50 gf} |
2.55±0.69N {260±70 gf} |
1.76±0.49 N {180±50 gf} |
||||||||||||
| Releasing force (RF) |
0.2 N {20 gf} min. |
0.49 N {50 gf} min. |
0.49 N {50 gf} min. |
0.7 N {70 gf} min. |
0.29 N {30 gf} min. |
0.49 N {50 gf} min. |
0.49 N {50 gf} min. |
||||||||||||
| Pretravel (PT) |
|
|
|
||||||||||||||||
Key Tops
B32-series Special Key Tops are available for projected plunger models. Refer to the Datasheet of B32 for details.
Precautions
Be sure to read the safety precautions common to all Tactile Switches for correct use.