Detection Switches
D3C Ultra Subminiature Detection Switch
Ultra Subminiature Detection Switch with Slide Mechanism and Lever Actuator
- Compact (8×6×4.2 mm (W×H×D)), and light (approximately 0.3 g) with long, 3-mm stroke.
- Built-in slide mechanism allows selection of shorting or non-shorting timing to match the application.
- Ideal for a wide variety of applications, including compact household appliances, audio equipment, office machines, and telecommunications equipment.
|
|
Actuator |
OF 1.28 N {130 gf} |
OF 0.39 N {40 gf} |
| Non-shorting Model |
Shorting Model |
Non-shorting Model |
Shorting Model |
Rotary lever |
D3C-1210 |
D3C-2210 |
D3C-1220 |
D3C-2220 |
| Contact Form |
| SPDT |
 |
Ratings
| Electrical ratings |
0.1 A at 30 VDC (resistive load) |
| Note: |
The ratings values apply under the following test conditions:
Ambient temperature: 20 ± 2ºC Ambient humidity: 65 ± 5% Operating frequency: 30 operations/min |
Characteristics
| Operating speed |
1 to 500 mm/s |
| Operating frequency |
Mechanical: 200 operations/min max. Electrical: 30 operations/min max. |
| Insulation resistance |
100 MΩ min. (at 250 VDC) |
Contact resistance (initial value) |
50 mΩ max. |
| Dielectric strength |
250 VAC, 50/60 Hz for 1 min between terminals of same polarity 250 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground |
| Vibration resistance |
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude |
| Shock resistance |
Destruction:1,000 m/s2{approx. 100G} max. Malfunction: 300 m/s2 {approx. 30G} max.
|
| Durability (see note2) |
50,000 operations min.(30 operations/min) |
| Degree of protection |
IEC IP00 |
| Degree of protection against electric shock |
Class Ⅲ |
| Proof tracking index (PTI) |
175 |
| Ambient operating temperature |
-20ºC to 80ºC (at ambient humidity of 60% max.)(with no icing) |
| Ambient operating humidity |
85% max. (for 5ºC to 35ºC) |
| Weight |
Approx. 0.3 g |
| Note:1. |
The data given above
are initial values. |
| 2. |
For testing conditions,
consult your OMRON sales representative. |
Note:1. |
All units are in millimeters unless otherwise indicated. |
2. |
Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions. |
|
D3C-1210/-2210 D3C-1220/-2220 |
 |
 |
| |
|
| Model |
Non-shorting Models |
Shorting Models |
| D3C-1210 |
D3C-1220 |
D3C-2210 |
D3C-2220 |
OF max. RF min. |
1.28 N {130 gf} (0.98 N) 0.10 N {10 gf} (0.15 N) |
0.39 N {40 gf} (0.29 N) 0.03 N {3 gf} (0.05 N) |
1.28 N {130 gf} (0.98 N) 0.10 N {10 gf} (0.15 N) |
0.39 N {40 gf} (0.29 N) 0.03 N {3 gf} (0.05 N) |
FP max. OP1 OP2 TTP |
4.8 mm 3.5± 0.3 mm 2.5± 0.3 mm 1.3± 0.4 mm |
4.8 mm 3.4± 0.3 mm 2.6± 0.3 mm 1.3± 0.4 mm |
| Note: |
The values for operating characteristics apply for operation in the A direction ( ) shown above. The values in parentheses indicate those for operation in the B direction ( ). |
 |
|
Switches
Products Lineup
Relational Contents