Relays
Sensors
Optical Communication Devices
Wireless & High Frequency Devices
By Name
By Category
Switches
Micro Sensing Devices
Foundry
Connectors
Touch Sensors
Face Recognition Sensor

Sealed Basic Switches

Search by product list
D2SW-P Sealed Subminiature Basic Switch
Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series.
  • Sealing by using rubber packing means the switch can be used in dust-proof or in temporary water-proof environments (IEC IP67).
  • Switch rating of 2A at 250 VAC possible with a single-leaf movable spring. Models for micro loads are also available.
  • Solder, quick-connect terminals (#110), PCB terminals and molded lead wires are available. Even-pitched PCB terminals are also standardized.
XF2C
JPN
2D3D
OrderingInformationRatings / CharacteristicsDimensions
Rating   Actuator
  Terminal
Solder terminals
Quick-connect terminals (#110)
PCB terminals
Molded lead wires
Uneven pitch
Even pitch
2A
Pin
plunger  
D2SW-P:Ordering Information1
D2SW-P2H
D2SW-
P2T
D2SW-
P2D
D2SW-P2B
D2SW-
P2M
Hinge
lever
D2SW-P:Ordering Information2
D2SW-P2L1H
D2SW-P2L1T
D2SW-P2L1D
D2SW-P2L1B
D2SW-P2L1M
Hinge roller
lever
D2SW-P:Ordering Information3
D2SW-P2L2H
D2SW-P2L2T
D2SW-P2L2D
D2SW-P2L2B
D2SW-P2L2M
Simulated
roller lever
D2SW-P:Ordering Information4
D2SW-P2L3H
D2SW-P2L3T
D2SW-P2L3D
D2SW-P2L3B
D2SW-P2L3M

0.1A

Pin
plunger  
D2SW-P:Ordering Information1
D2SW-P01H
D2SW-P01T
D2SW-P01D
D2SW-P01B
D2SW-P01M
Hinge
lever
D2SW-P:Ordering Information2
D2SW-P01L1H
D2SW-P01L1T
D2SW-P01L1D
D2SW-P01L1B
D2SW-P01L1M
Hinge roller
lever
D2SW-P:Ordering Information3
D2SW-P01L2H
D2SW-P01L2T
D2SW-P01L2D
D2SW-P01L2B
D2SW-P01L2M
Simulated
roller lever
D2SW-P:Ordering Information4
D2SW-P01L3H
D2SW-P01L3T
D2SW-P01L3D
D2SW-P01L3B
D2SW-P01L3M
Note: Consult your OMRON sales representative for details on SPST-NO and SPST-NC models.

Contact Form
SPDT SPST-NC
(Molded lead wire models only)
SPST-NO
(Molded lead wire models only)
D2SW-P:Ordering Information5 D2SW-P:Ordering Information5 D2SW-P:Ordering Information5
Note: Lead wire colors are indicated in perentheses.
OrderingInformationRatings / CharacteristicsDimensions
Ratings
Model
Rated voltage
Resistive load
D2SW-P2
30 VDC
2 A
250 VAC
D2SW-P01
30 VDC
0.1 A
125 VAC
Note: The ratings values apply under the following test conditions.
Ambient temperature: 20 ±2ºC
Ambient humidity: 65 ±5%
Operating frequency: 20 operations/min

Characteristics
Item
Model
D2SW-P2
D2SW-P01
Operating speed 0.1 mm to 500 mm/s (pin plunger models)
Operating frequency Mechanical: 120 operations/min max.
Electrical: 20 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial value) Terminal models:50 mΩ max.
Molded lead wire models:100 mΩ max.
Terminal models:100 mΩ max.
Molded lead wire models:150 mΩ max.
Dielectric strength
(see note 2)
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarities
600 VAC, 50/60 Hz for 1 min between terminals of the same polarities
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts
Vibration resistance
(see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
(see note 3)
Destruction: 1,000 m/s2 {approx. 100G} max.
Malfunction: 300 m/s2 {approx. 30G} max.
Durability
(see note 4)
Mechanical: 1,000,000 operations min.
(60 operations/min.)
Electrical: 50,000 operations min.
(20 operations min.)
Mechanical: 1,000,000 operations min.
(60 operations/min.)
Electrical: 200,000 operations min.
(20 operations min.)
Degree of protection IEC IP67 (See note 5)
(excluding the terminals on terminal models)
Degree of protection against electric shock Class Ⅰ
Proof tracking index (PTI) 175
Ambient operating temperature -20ºC to 70ºC (at ambient humidity of 60% max.)
(with no icing)
Ambient operating humidity 85% max. (for 5ºC to 35ºC)
Weight Approx.2 g (pin plunger models with terminals)
Note: 1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For the pin plunger models, the above values apply for both the free position and total travel position. For the lever models, the values apply at the total travel position. Contact opening or closing time is within 1 ms.
4. Consult your OMRON sales representative for testing conditions.
5. The test to meet standards checks for water intrusion after immersion for 30 minutes. The test does not check for switching operation underwater. Refer to "Degree of Protection" of "Instructions for Correct Use".
OrderingInformationRatings / CharacteristicsDimensions
Dimensions and Operating Characteristics
Note: 1. All units are in millimeters unless otherwise indicated.
2. The following illustrations and drawings are for solder terminal models. Refer to page 229 for details on models with quick-connect terminals (#110) or PCB terminals or molded lead wires.
3. The in the model number is for the contact form code or the terminal code.
4. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
5. The operating characteristics are for operation in the A direction ( ).
Pin Plunger Models
D2SW-P2
D2SW-P01
D2SW_P:Dimensions1
D2SW_P:Dimensions2
Model
D2SW-P2
D2SW-P01
OF max.
RF min.
1.8 N {183 gf}
D2SW_P:Dimensions40.2 N {20 gf}
PT max.
OT min.
MD max.
0.6 mm
0.4 mm
0.15 mm
OP 8.4± 0.3 mm


Hinge Lever Models
D2SW-P2L1
D2SW-P01L1
D2SW_P:Dimensions3
 
Model
D2SW-P2L1
D2SW-P01L1
OF max.
RF min.
0.6 N {61 gf}
0.05 N {5 gf}
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
13.6 mm
8.8± 0.8 mm


Hinge Roller Lever Models
D2SW-P2L2
D2SW-P01L2
D2SW_P:Dimensions5
D2SW_P:Dimensions6
Model
D2SW-P2L2
D2SW-P01L2
OF max.
RF min.
0.6 N {61 gf}
0.05 N {5 gf}
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
19.3 mm
14.5± 0.8 mm


Simulated Roller Lever Models
D2SW-P2L3
D2SW-P01L3
D2SW_P:Dimensions7
D2SW_P:Dimensions8
Model
D2SW-P2L3
D2SW-P01L3
OF max.
RF min.
0.6 N {61 gf}
0.05 N {5 gf}
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
15.5 mm
10.7± 0.8 mm