D2FW-G Sealed Basic Switch for Vehicles
A Sealed Switch for Mechanical Detection in Automobiles and Industrial Vehicles (Conforming to IP67)
  • Single-point mounting with an M4 screw.
  • ncorporates a fixed leaf lever for tough environments.
  • Molded lead wires are installed using lead-free connections for environmental conservation.
XF2C
JPN
2D3D
OrderingInformationRatings / CharacteristicsDimensions
Actuator Rated load Contact specifications
(molded lead wires)
Model
Leaf lever
D2FW-G:Ordering Information1
1 A SPDT D2FW-G271M
SPST-NC D2FW-G272M
SPST-NO D2FW-G273M
0.1 A SPDT D2FW-G071M
SPST-NC D2FW-G072M
SPST-NO D2FW-G073M
Long leaf lever
D2FW-G:Ordering Information2
1 A SPDT D2FW-G281M
SPST-NC D2FW-G282M
SPST-NO D2FW-G283M
0.1 A SPDT D2FW-G081M
SPST-NC D2FW-G082M
SPST-NO D2FW-G083M
Note: The standard length of the molded lead wires (AVS0.5) is 30 cm.

Contact Form

SPDT SPST-NC SPST-NO
D2FW-G:Ordering Information3 D2FW-G:Ordering Information4 D2FW-G:Ordering Information5
*The color in parentheses indicates the color of the lead wire.
OrderingInformationRatings / CharacteristicsDimensions
Ratings
Rated voltage
D2FW-G2
(general-load models)
D2FW-G0
(micro load models)
Resistive load
30 VDC 1 A 0.1 A
Note:
The ratings values apply under the following test conditions:
Ambient temperature:20±2°C
Ambient humidity:65 ±5%
Operating frequency:30 operations/min

Characteristics
Item
D2FW-G2
D2FW-G0
Operating speed 1 to 500 mm/s
Operating frequency Mechanical:120 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 100 mΩ max. 150 mΩ max.
Dielectric strength 600 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts
Vibration resistance
(see note 2)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
(see note 2)
Destruction: 1,000 m/s2max.
Malfunction: 300 m/s2max.
Durability
(see note 3)
Mechanical: 300,000 operations min.(60 operations/min)
Electrical: 30,000 operations min.(20 operations/min) Electrical: 100,000 operations min.(20 operations/min)
Degree of protection IEC IP67
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -40ºC to 85ºC (at ambient humidity of 60% max.) (with no icing)
Ambient operating humidity 95% max. (for 5ºC to 35ºC)
Weight Approx. 10.4 g (SPDT type)
Note:
1.
The data given above are initial values.
 
2.
For the pin plunger models, the above values apply for use at the free position, operating position, and total travel position.
For the lever models, they apply at the total travel position.
The values shown apply for malfunctions of 1 ms max.
 
3.
For testing conditions, consult your OMRON sales representative.
OrderingInformationRatings / CharacteristicsDimensions
Note: 1. All units are in millimeters unless otherwise indicated.
  2. The operating characteristics are for operation in the A direction ( ).
  3. The in the model number is for rating code and contact form code.
Leaf Lever Models
D2FW-G7M
D2FW-5:Dimensions1 D2FW-5:Dimensions2
Model
Leaf Lever Models
D2FW-G7M
OF max.
RF min.
2.45 N {250gf}
0.29 N {30gf}
OT min.
MD max.
1.0 mm
1.0 mm
FP max.
OP
TTP
15.5 mm
11.5 ± 2 mm
6.5mm(reference value)

Long Leaf Lever Models
D2FW-G8M
D2FW-5:Dimensions3 D2FW-5:Dimensions4
Model
Long Leaf Lever Models
D2FW-G8M
OF
RF min.
2.94 N {300gf}
0.59 N {60gf}
OT min.
MD max.
1.0 mm
1.0 mm
FP max.
OP
TTP
19 mm
12 ± 2 mm
8.5mm(reference value)