Sealed Basic Switches
D2FW-G Sealed Basic Switch for Vehicles
A Sealed Switch for Mechanical Detection in Automobiles and Industrial Vehicles (Conforming to IP67)
- Single-point mounting with an M4 screw.
- ncorporates a fixed leaf lever for tough environments.
- Molded lead wires are installed using lead-free connections for environmental conservation.
|
|
| Actuator |
Rated load |
Contact specifications (molded lead wires) |
Model |
Leaf lever  |
1 A |
SPDT |
D2FW-G271M |
| SPST-NC |
D2FW-G272M |
| SPST-NO |
D2FW-G273M |
| 0.1 A |
SPDT |
D2FW-G071M |
| SPST-NC |
D2FW-G072M |
| SPST-NO |
D2FW-G073M |
Long leaf lever  |
1 A |
SPDT |
D2FW-G281M |
| SPST-NC |
D2FW-G282M |
| SPST-NO |
D2FW-G283M |
| 0.1 A |
SPDT |
D2FW-G081M |
| SPST-NC |
D2FW-G082M |
| SPST-NO |
D2FW-G083M |
| Note: |
The standard length of the molded lead wires (AVS0.5) is 30 cm. |
Contact Form
*The color in parentheses indicates the color of the lead wire.
Ratings
| Rated voltage |
D2FW-G2 (general-load models) |
D2FW-G0 (micro load models) |
| Resistive load |
| 30 VDC |
1 A |
0.1 A |
Note: |
The ratings values apply under the following test conditions:
Ambient temperature:20±2°C
Ambient humidity:65
±5% Operating frequency:30 operations/min |
Characteristics
| Item |
D2FW-G2 |
D2FW-G0 |
| Operating speed |
1 to 500 mm/s |
| Operating frequency |
Mechanical:120 operations/min max. Electrical: 30 operations/min max. |
| Insulation resistance |
100 MΩ min. (at 500 VDC) |
| Contact resistance |
100 mΩ max. |
150 mΩ max. |
| Dielectric strength |
600 VAC, 50/60 Hz for 1 min between terminals of the same polarity 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts |
Vibration resistance (see note 2) |
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance (see note 2) |
Destruction: 1,000 m/s2max. Malfunction: 300 m/s2max. |
Durability (see note 3) |
Mechanical: 300,000 operations min.(60 operations/min) |
| Electrical: 30,000 operations min.(20 operations/min) |
Electrical: 100,000 operations min.(20 operations/min) |
| Degree of protection |
IEC IP67 |
| Degree of protection against electric shock |
Class I |
| Proof tracking index (PTI) |
175 |
| Ambient operating temperature |
-40ºC to 85ºC (at ambient humidity of 60% max.) (with no icing) |
| Ambient operating humidity |
95% max. (for 5ºC to 35ºC) |
| Weight |
Approx. 10.4 g (SPDT type) |
Note: |
1. |
The data given above are initial values. |
| |
2. |
For the pin plunger models, the above values apply for use at the free position, operating position, and total travel position.
For the lever models, they apply at the total travel position. The values shown apply for malfunctions of 1 ms max. |
| |
3. |
For testing conditions, consult your OMRON sales representative. |
| Note: |
1. |
All units are in millimeters unless otherwise indicated. |
| |
2. |
The operating characteristics are for operation in the A direction ( ). |
| |
3. |
The in the model number is for rating code and contact form code. |
|
Leaf Lever Models D2FW-G 7 M |
 |
 |
| Model |
Leaf Lever Models |
D2FW-G 7 M |
OF max. RF min. |
2.45 N {250gf} 0.29 N {30gf} |
OT min. MD max. |
1.0 mm 1.0 mm |
FP max. OP TTP |
15.5 mm 11.5 ± 2 mm 6.5mm(reference value) |
|
|
Long Leaf Lever Models D2FW-G 8 M |
 |
 |
| Model |
Long Leaf Lever Models |
D2FW-G 8 M |
OF RF min. |
2.94 N {300gf} 0.59 N {60gf} |
OT min. MD max. |
1.0 mm 1.0 mm |
FP max. OP TTP |
19 mm 12 ± 2 mm 8.5mm(reference value) |
|
|
|
Switches
Products Lineup
Relational Contents
Contact Us
|