Ultra Subminiature Basic Switches (J-Size)
D2MQ Ultra Subminiature Basic Switch
Snap-action Switch with Ultra Subminiature Size (6.5×8.2×2.7 mm (H×W×D)) and Light Weight (0.3 g)
- Excellent electrical characteristics and a snap-action mechanism in spite of its ultra small size.
- Gold-plated (Au-P) contacts for micro load switching available in addition to silver-plated contacts (Ag-P).
- Ideal for applications where size is extremely limited and high reliability is demanded, such as in
compact audio, optical. and telecommunications equipment.
|
|
| Note: |
The terminal shape drawings indicate the shape when the Switch is viewed from the direction of the arrow in the drawing below. |
| |
 |
Contact Form SPDT |
 |
Ratings
|
Type
|
Silver-plated contact type
|
Gold-plated contact type
|
| Resistive load |
| 30 VDC |
0.5A |
50mA |
| Note: |
The ratings values apply under the following test conditions:
Ambient temperature:20±2ºC Ambient humidity: 65±5% Operating frequency: 30 operations/min |
Characteristics
| Operating speed (see note 2) |
0.1 mm to 0.5 m/s |
| Operating frequency |
| Mechanical: |
60 operations/min max. |
| Electrical: |
30 operations/min max. |
|
| Insulation resistance |
100 MΩ min. (at 250
VDC) |
| Contact resistance (initial
value) |
100 mΩ max. |
| Dielectric strength |
500 VAC, 50/60 Hz for 1 min between terminals at the same polarity 500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground |
| Vibration resistance (see note 3) |
Malfunction:10 to 55 Hz,
1.5-mm double amplitude (see note2) |
| Shock resistance (see note 3) |
| Destruction: |
1,000 m/s2 {approx. 100G} max. |
| Malfunction: |
300 m/s2 {approx. 30G} max. |
|
| Durability (see note 4) |
| Mechanical: |
30,000 operations min.
(60 operations/min) |
| Electrical: |
10,000 operations min. (30 operations/min) |
|
| Degree of protection |
IEC IP40 |
| Degree of protection against electric shock |
Class I |
| Proof tracking index (PTI) |
175 |
| Ambient operating temperature |
-15ºC to 70ºC (at ambient humidity
of 60% max.)(with no icing) |
| Ambient operating humidity |
35% to 85% (for 5ºC to 35 ºC) |
| Weight |
Approx. 0.3 g |
| Note: |
1. |
The data given above are initial values. |
|
2. |
The values are for the pin plunger model. (For different models, Consult your OMRON representative.) |
| |
3. |
Malfunction: 1 ms max. |
| |
4. |
For testing conditions,consult your OMRON
sales representative. |
| Note: |
1. |
All units are in
millimeters unless otherwise indicated. |
| |
2. |
Unless otherwise
specified, a tolerance of 0.15 mm applies to
all dimensions. |
| |
3. |
The following illustrations
are for the straight terminal models. Those
for the left-angled terminals and right-angled
terminals are different from straight terminal
models in terminal size only. Refer to Terminals
on page 211 for these terminals. |
| |
4. |
The operating characteristics
are for operation in the A direction( ) |
Pin Plunger Models D2MQ-1 (Straight terminals) D2MQ-1-TL (Left -angled terminals) D2MQ-1-TR (Right -angled terminals) D2MQ-1-105 (Straight terminals) |
 |
 |
| OF max. RF min. |
1.18 N {120 gf}
0.19 N {20 gf} |
| PT max. OT min. MD max. |
0.4 mm
0.1 mm
0.1 mm |
| OP |
5.7±0.2 mm |
|
|
Leaf Lever Models D2MQ-1L (Straight terminals) D2MQ-1L-TL (Left -angled terminals) D2MQ-1L-TR (Right -angled terminals) D2MQ-1L-105 (Straight terminal) |
 |
 |
| OF max. RF min. |
0.59 N {60 gf}
0.08 N {8 gf} |
| PT max. OT min. MD max. |
2.4 mm
0.3 mm
0.7 mm |
| FP max. OP |
9.6 mm
6.7±0.5 mm |
|
|
Hinge Leaf Lever Models D2MQ-4L-1 (Straight Terminals) D2MQ-4L-1-L (Left-angled terminals) DD2MQ-4L-1-R (Right-angled terminals) D2MQ-4L-105-1 (Straight Terminals) D2MQ-4L-105-1-L (Left-angled terminals) D2MQ-4L-105-1-R (Right-angled terminals) |
 |
 |
| OF max. RF min. |
0.39 N {40 gf}
0.04 N {4 gf} |
| PT max. OT min. MD max. |
2.1 mm
0.3 mm
0.7 mm |
| FP max. OP |
8.7 mm
7.1±0.5 mm |
|
|