PCB Mounting Solid-State Relays
G3R/G3RD Solid-State Relay
Compact SSRs Ideal for Built-in Applications
- Vertical, compact SSRs with an operation indicator offered in versatile variations.
- High dielectric strength of 2,500 VAC for 2-A models.
- High-voltage DC version also acailable.
- Approved by UL and CSA.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Terminals |
Isolation |
Zero cross function |
Indicator |
Rated output load (Applicable output load) |
Rated input voltage |
Model |
| PCB |
Phototriac |
Yes |
Yes |
2A at 100 to 120 VAC
(2A at 75 to 132 VAC) (see note 1) |
DC5V,12V,24V |
G3R-102PN-US |
| No |
G3R-102PLN-US |
| Yes |
2A at 100 to 240 VAC
(2A at 75 to 264 VAC) (see note 2) |
G3R-202PN-US |
| No |
G3R-202PLN-US |
| Photocoupler |
-- |
Yes |
1.5A at 5 to 110 VDC (1.5A at 3 to 125 VDC) |
G3RD-101PN-US |
2A at 4 to 48 VDC (2A at 3 to 52.8 VDC) (see note 3) |
G3RD-X02PN-US |
| Note: 1. |
Product is labelled"125VAC". |
| 2. |
Product is labelled"250VAC". |
| 3. |
Product is labelled"50VDC". |
Specifications
Ratings
Input(AC Output With Zero Cross Function)
| Model |
Rated voltage |
Operating voltage |
Impedance |
Voltage level |
Must operate voltage |
Must release
Voltage |
G3R-102PN
G3R-202PN |
5VDC |
4 to 6 VDC |
250Ω±20% |
3.5 VDC max. |
0.375 VDC min. |
| 12VDC |
9.6 to 14.4 VDC |
600Ω±20% |
8.4 VDC max. |
0.9 VDC min. |
| 24VDC |
19.2 to 28.8 VDC |
1.5kΩ±20% |
16.8 VDC max. |
1.8 VDC min. |
Input(AC Output With Zero Cross Function,DC Output)
| Model |
Rated voltage |
Operating voltage |
Impedance |
Voltage level |
Must operate voltage |
Must release
Voltage |
G3R-102PLN
G3R-202PLN
G3RD-X02PN
G3RD-101PN |
5VDC |
4 to 6 VDC |
300Ω±20% |
3.5 VDC max. |
0.375 VDC min. |
| 12VDC |
9.6 to 14.4 VDC |
750Ω±20% |
8.4 VDC max. |
0.9 VDC min. |
| 24VDC |
19.2 to 28.8 VDC |
1.5kΩ±20% |
16.8 VDC max. |
1.8 VDC min. |
|
Output
| Model |
Rated voltage |
Voltage level |
| Load voltage range |
Load current |
Inrush current |
G3R-102PN
G3R-102PLN |
100 to 120 VAC |
75 to 132 VDC |
0.1 to 2A |
30A(60Hz, 1cycle) |
G3R-202PN
G3R-202PLN |
100 to 240 VAC |
75 to 264 VDC |
0.1 to 2A |
| G3RD-X02PN |
4 to 48 VDC |
3 to 52.8 VDC |
0.01 to 2A |
8A(10ms) |
| G3RD-101PN |
5 to 110 VDC |
3 to 125 VDC |
0.01 to 1.5A |
2.5A(10ms) |
|
|
Characteristics
| Item |
G3R-102PLN |
G3R-102PN |
G3R-202PLN |
G3R-202PN |
G3RD-X02PN/-101PN |
| Operate time |
1 ms max. |
1/2 of load power source cycle + 1 ms max. |
1 ms max. |
1/2 of load power source cycle + 1 ms max. |
1 ms max. |
| Release time |
1/2 of load power source cycle + 1 ms max. |
1 ms max. |
Output ON voltage drop |
1.6V (RMS) max. |
1.5V max. |
| Leakage current |
2mA max.(at 100 VAC) |
2mA max.(at 100VAC)
5mA max.(at 200VAC) |
0.1mA max.(at 125 VDC)
0.1mA max.(at 50 VDC) |
Insulation resistance |
100MΩ min.(at 500 VDC) |
| Dlelectric strength |
2,500 VAC, 50/60 Hz for 1min |
2,500 VAC, 50/60 Hz for 1min |
| Vibration resistance |
Malfunction:10 to 55Hz, 1.5mm double amplitude |
| Shock resistance |
Malfunction:1,000m/s2 |
Ambient
temperature |
Operating: -30ºC to 80ºC(with no icing or condensation)
Storage: -30ºC to 100ºC(with no icing or condensation) |
| Approved standards |
UL508File No.E64562, CSA C22.2(No.14)File No.35535 |
| Ambient humidity |
Operating:45% to 85% |
| Weight |
Approx.18g |
Characteristics
Note: All units are milimeters unless otherwise indicated
|
 |
 |
|