Relays
Sensors
Foundry
By Part# / Name
By Category
Switches
Micro Sensing Devices
Face Recognition Sensor
Connectors
Optical Communication Devices

PCB Mounting Solid-State Relays

Search by product list

G3R/G3RD Solid-State Relay

Compact SSRs Ideal for Built-in Applications

  • Vertical, compact SSRs with an operation indicator offered in versatile variations.
  • High dielectric strength of 2,500 VAC for 2-A models.
  • High-voltage DC version also acailable.
  • Approved by UL and CSA.
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Terminals Isolation Zero cross
function
Indicator Rated output load
(Applicable output load)
Rated input
voltage
Model
PCB Phototriac Yes Yes 2A at 100 to 120 VAC
(2A at 75 to 132 VAC)
(see note 1)
DC5V,12V,24V G3R-102PN-US
No G3R-102PLN-US
Yes 2A at 100 to 240 VAC
(2A at 75 to 264 VAC)
(see note 2)
G3R-202PN-US
No G3R-202PLN-US
Photocoupler -- Yes 1.5A at 5 to 110 VDC
(1.5A at 3 to 125 VDC)
G3RD-101PN-US
2A at 4 to 48 VDC
(2A at 3 to 52.8 VDC)
(see note 3)
G3RD-X02PN-US
Note: 1. Product is labelled"125VAC".
2. Product is labelled"250VAC".
3. Product is labelled"50VDC".
OrderingInformationRatings / CharacteristicsDimensions
Specifications
Ratings
Input(AC Output With Zero Cross Function)
Model Rated voltage Operating voltage Impedance Voltage level
Must operate
voltage
Must release
Voltage
G3R-102PN
G3R-202PN
5VDC 4 to 6 VDC 250Ω±20% 3.5 VDC max. 0.375 VDC min.
12VDC 9.6 to 14.4 VDC 600Ω±20% 8.4 VDC max. 0.9 VDC min.
24VDC 19.2 to 28.8 VDC 1.5kΩ±20% 16.8 VDC max. 1.8 VDC min.

Input(AC Output With Zero Cross Function,DC Output)
Model Rated voltage Operating voltage Impedance Voltage level
Must operate
voltage
Must release
Voltage
G3R-102PLN

G3R-202PLN
G3RD-X02PN
G3RD-101PN
5VDC 4 to 6 VDC 300Ω±20% 3.5 VDC max. 0.375 VDC min.
12VDC 9.6 to 14.4 VDC 750Ω±20% 8.4 VDC max. 0.9 VDC min.
24VDC 19.2 to 28.8 VDC 1.5kΩ±20% 16.8 VDC max. 1.8 VDC min.

Output
Model Rated voltage Voltage level
Load voltage range Load current Inrush current
G3R-102PN
G3R-102PLN
100 to 120 VAC 75 to 132 VDC 0.1 to 2A 30A(60Hz, 1cycle)
G3R-202PN
G3R-202PLN
100 to 240 VAC 75 to 264 VDC 0.1 to 2A
G3RD-X02PN 4 to 48 VDC 3 to 52.8 VDC 0.01 to 2A 8A(10ms)
G3RD-101PN 5 to 110 VDC 3 to 125 VDC 0.01 to 1.5A 2.5A(10ms)

Characteristics
Item G3R-102PLN G3R-102PN G3R-202PLN G3R-202PN G3RD-X02PN/-101PN
Operate time 1 ms max. 1/2 of load power
source cycle + 1
ms max.
1 ms max. 1/2 of load power
source cycle + 1
ms max.
1 ms max.
Release time 1/2 of load power source cycle + 1 ms max. 1 ms max.
Output ON voltage
drop
1.6V (RMS) max. 1.5V max.
Leakage current 2mA max.(at 100 VAC) 2mA max.(at 100VAC)
5mA max.(at 200VAC)
0.1mA max.(at 125 VDC)
0.1mA max.(at 50 VDC)
Insulation
resistance
100MΩ min.(at 500 VDC)
Dlelectric strength 2,500 VAC, 50/60 Hz for 1min 2,500 VAC, 50/60 Hz for 1min
Vibration resistance Malfunction:10 to 55Hz, 1.5mm double amplitude
Shock resistance Malfunction:1,000m/s2
Ambient
temperature
Operating: -30ºC to 80ºC(with no icing or condensation)
Storage: -30ºC to 100ºC(with no icing or condensation)
Approved standards UL508File No.E64562, CSA C22.2(No.14)File No.35535
Ambient humidity Operating:45% to 85%
Weight Approx.18g
OrderingInformationRatings / CharacteristicsDimensions
Characteristics
Note: All units are milimeters unless otherwise indicated

G5R:Dimensions1 G5R:Dimensions2
Related Links
Technology
Application Guide