Relays
Sensors
Foundry
By Part# / Name
By Category
Switches
Micro Sensing Devices
Facial Image Sensing Technology
Connectors
Optical Communication Devices

PCB Mounting Solid-State Relays

Search by product list

G3M PCB Mounting Solid-State Relay

Zero Cross Models Added to Compact, Low-cost G3M Series

  • This design for high-density PCB applications.
  • DC input-AC output for up to 5-A load.
  • Approved by UL and CSA.
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Isolation Input terminal
pitch
Zero cross
function
Indicator Rated output load
(Applicable output load)
Rated input
voltage
Model
Phototriac 7.62mm Yes No 2A at 100 to 240 VAC
(2A at 75 to 264 VAC)
5 VDC G3M-202P-US
12 VDC
24 VDC
3A at 100 to 240 VAC
(3A at 75 to 264 VAC)
5 VDC G3M-203P
12 VDC
24 VDC
No 2A at 100 to 120 VAC
(2A at 75 to 132 VAC)
5 VDC G3M-102PL-US
12 VDC
24 VDC
2A at 100 to 240 VAC
(2A at 75 to 264 VAC)
5 VDC G3M-202PL-US
12 VDC
24 VDC
3A at 100 to240 VAC
(3A at 75 to 264 VAC)
5 VDC G3M-203PL
12 VDC
24 VDC
5A at 100 to 240 VAC
(5A at 75 to 264 VAC)
5 VDC G3M-205PL
(New)
12 VDC
24 VDC
Note: 1. TŰV marking is available with "-UTU" in place of "-US" on the part number.
2. UL, CSA and VDE approval of G3M-205PL is pending.
Isolation Input terminal
pitch
Zero cross
function
Indicator Rated output load
(Applicable output load)
Rated input
voltage
Model
Phototriac 5.08mm Yes No 2A at 100 to 240 VAC
(2A at 75 to 132 VAC)
5 VDC G3M-202P-US-4
12 VDC
24 VDC
3A at 100 to 240 VAC
(3A at 75 to 264 VAC)
5 VDC G3M-203P-4
12 VDC
24 VDC
No 2A at 100 to 120 VAC
(3A at 75 to 264 VAC)
5 VDC G3M-102PL-US-4
12 VDC
24 VDCs
2A at 100 to 240 VAC
(2A at 75 to 264 VAC)
5 VDC G3M-202PL-US-4
12 VDC
24 VDC
3A at 100 to240 VAC
(3A at 75 to 264 VAC)
5 VDC G3M-203PL-4
12 VDC
24 VDC
5A at 100 to 240 VAC
(5A at 75 to 264 VAC)
5 VDC G3M-205PL-4
(New)
12 VDC
24 VDC
OrderingInformationRatings / CharacteristicsDimensions
Specifications
Input
Rated voltage Operating voltage Impedance Voltage levels
Must operate voltage Must release Voltage
5VDC 4 to 6 VDC 300Ω±20% 4 VDC max. 1 VDC min.
12VDC 9.6 to 14.4 VDC 800Ω±20% 9.6 VDC max.
24VDC 19.2 to 28.8 VDC 1.6kΩ±20% 19.2 VDC max.
Note: 1. Each model has 5-VDC, 12-VDC input versions.

Output
Model Rated voltage Applicable load
Load voltage Load current lnrush current
G3M-102PL-US (-4) 100 to 120 VAC 75 to 132 VAC 0.1 to 2A 30A(60Hz, 1cycle)
G3M-202P(L)-US (-4) 100 to 240 VAC 75 to 264 VAC
G3M-203P(L) (-4) 0.1 to 3A 45A(60Hz, 1cycle)
G3M-205P(L) (-4) 0.1 to 5A

Characteristics
Item G3M-102PL-US(-4) G3M-202P(L)-US(-4) G3M-203P(L)(-4) G3M-205P(L)(-4)
Operate time 1 ms max.(1/2 of load power source cycle + 1 ms max. for G3M-202P,G3M-203P,G3M-205P)
Release time 1/2 of load power source cycle + 1 ms max.
Output ON voltage
drop
1.6V (RMS) max.
Leakage current 2mA max.(at 100 VAC) 2mA max.(at 100 VAC)
5mA max.(at 200 VAC)
1.5mA(at 200VAC)
Insulation
resistance
1,000MΩ min.(at 500 VDC)
Dlelectric strength 2,000 VAC, 50/60 Hz for 1min 2,500 VAC, 50/60 Hz for 1min
Vibration resistance Malfunction:10 to 55Hz, 1.5mm double amplitude
Shock resistance Malfunction:1,000m/s2
Ambient
temperature
Operating: -30ºC to 80ºC(with no icing or condensation)
Storage: -30ºC to 100ºC(with no icing or condensation)
Ambient humidity Operating:45% to 85%
Weight Approx.15g Approx.25g
OrderingInformationRatings / CharacteristicsDimensions
Characteristics
Note: All units are milimeters unless otherwise indicated

G5M:Dimensions1 G5M:Dimensions2
Related Links
Technology
Application Guide