PCB Mounting Solid-State Relays
G3M PCB Mounting Solid-State Relay
Zero Cross Models Added to Compact, Low-cost G3M Series
- This design for high-density PCB applications.
- DC input-AC output for up to 5-A load.
- Approved by UL and CSA.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Isolation |
Input terminal pitch |
Zero cross function |
Indicator |
Rated output load (Applicable output load) |
Rated input voltage |
Model |
| Phototriac |
7.62mm |
Yes |
No |
2A at 100 to 240 VAC
(2A at 75 to 264 VAC) |
5 VDC |
G3M-202P-US |
| 12 VDC |
| 24 VDC |
3A at 100 to 240 VAC
(3A at 75 to 264 VAC) |
5 VDC |
G3M-203P |
| 12 VDC |
| 24 VDC |
| No |
2A at 100 to 120 VAC
(2A at 75 to 132 VAC) |
5 VDC |
G3M-102PL-US |
| 12 VDC |
| 24 VDC |
2A at 100 to 240 VAC
(2A at 75 to 264 VAC) |
5 VDC |
G3M-202PL-US |
| 12 VDC |
| 24 VDC |
3A at 100 to240 VAC
(3A at 75 to 264 VAC) |
5 VDC |
G3M-203PL |
| 12 VDC |
| 24 VDC |
5A at 100 to 240 VAC
(5A at 75 to 264 VAC) |
5 VDC |
G3M-205PL
(New) |
| 12 VDC |
| 24 VDC |
| Note: 1. |
TŰV marking is available with "-UTU" in place of "-US" on the part number. |
| 2. |
UL, CSA and VDE approval of G3M-205PL is pending. |
| Isolation |
Input terminal pitch |
Zero cross function |
Indicator |
Rated output load (Applicable output load) |
Rated input voltage |
Model |
| Phototriac |
5.08mm |
Yes |
No |
2A at 100 to 240 VAC
(2A at 75 to 132 VAC) |
5 VDC |
G3M-202P-US-4 |
| 12 VDC |
| 24 VDC |
3A at 100 to 240 VAC
(3A at 75 to 264 VAC) |
5 VDC |
G3M-203P-4 |
| 12 VDC |
| 24 VDC |
| No |
2A at 100 to 120 VAC
(3A at 75 to 264 VAC) |
5 VDC |
G3M-102PL-US-4 |
| 12 VDC |
| 24 VDCs |
2A at 100 to 240 VAC
(2A at 75 to 264 VAC) |
5 VDC |
G3M-202PL-US-4 |
| 12 VDC |
| 24 VDC |
3A at 100 to240 VAC
(3A at 75 to 264 VAC) |
5 VDC |
G3M-203PL-4 |
| 12 VDC |
| 24 VDC |
5A at 100 to 240 VAC
(5A at 75 to 264 VAC) |
5 VDC |
G3M-205PL-4
(New) |
| 12 VDC |
| 24 VDC |
Specifications
Input
| Rated voltage |
Operating voltage |
Impedance |
Voltage levels |
| Must operate voltage |
Must release Voltage |
| 5VDC |
4 to 6 VDC |
300Ω±20% |
4 VDC max. |
1 VDC min. |
| 12VDC |
9.6 to 14.4 VDC |
800Ω±20% |
9.6 VDC max. |
| 24VDC |
19.2 to 28.8 VDC |
1.6kΩ±20% |
19.2 VDC max. |
| Note: 1. |
Each model has 5-VDC, 12-VDC input versions. |
Output
| Model |
Rated voltage |
Applicable load |
| Load voltage |
Load current |
lnrush current |
| G3M-102PL-US (-4) |
100 to 120 VAC |
75 to 132 VAC |
0.1 to 2A |
30A(60Hz, 1cycle) |
| G3M-202P(L)-US (-4) |
100 to 240 VAC |
75 to 264 VAC |
| G3M-203P(L) (-4) |
0.1 to 3A |
45A(60Hz, 1cycle) |
| G3M-205P(L) (-4) |
0.1 to 5A |
|
Characteristics
| Item |
G3M-102PL-US(-4) |
G3M-202P(L)-US(-4) |
G3M-203P(L)(-4) |
G3M-205P(L)(-4) |
| Operate time |
1 ms max.(1/2 of load power source cycle + 1 ms max. for G3M-202P,G3M-203P,G3M-205P) |
| Release time |
1/2 of load power source cycle + 1 ms max. |
Output ON voltage drop |
1.6V (RMS) max. |
| Leakage current |
2mA max.(at 100 VAC) |
2mA max.(at 100 VAC)
5mA max.(at 200 VAC) |
1.5mA(at 200VAC) |
Insulation resistance |
1,000MΩ min.(at 500 VDC) |
| Dlelectric strength |
2,000 VAC, 50/60 Hz for 1min |
2,500 VAC, 50/60 Hz for 1min |
| Vibration resistance |
Malfunction:10 to 55Hz, 1.5mm double amplitude |
| Shock resistance |
Malfunction:1,000m/s2 |
Ambient
temperature |
Operating: -30ºC to 80ºC(with no icing or condensation)
Storage: -30ºC to 100ºC(with no icing or condensation) |
| Ambient humidity |
Operating:45% to 85% |
| Weight |
Approx.15g |
Approx.25g |
Characteristics
Note: All units are milimeters unless otherwise indicated
|
 |
 |
|