PCB Mounting Solid-State Relays
G3DZ Solid-State Relay
SSR ldentical to the G6D in Size with a Maximum AC/DC Switching Current of 0.6A
- Switching 0.6A at 240VAC or 100VDC.
- 10-µA current leakage max. between open output terminals.
- 2,500-VAC dielectric strength ensured between input and output terminals.
- Input resistor and varistor incorporated models available.
- Switching full-and harf-wave rectified alternating currents.
- Approved by UL and CSA.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Contact form |
Isolation |
Zero cross
function |
Indicator |
Applicable output load |
Rated input
voltage |
Model |
| SPST-NO |
Photo-voltage coupler |
No |
No |
0.6A at
5 to 240 VAC
5 to 100 VDC |
5 VDC |
G3DZ-2R6PL |
| 12 VDC |
| 24 VDC |
Ratings
Input
| Rated voltage |
Operating voltage |
Imput impedance |
Voltage levels |
| Must operate |
Must release |
| 5VDC |
4 to 6 VDC |
830Ω±20% |
4 VDC max. |
1 VDC min. |
| 12VDC |
9.6 to 14.4 VDC |
2KΩ±20% |
9.6 VDC max. |
| 24VDC |
19.2 to 28.8 VDC |
4KΩ±20% |
19.2 VDC max. |
Output
| Rated voltage |
Load voltage |
Load current |
Inrush current |
| 5 to 240 VAC,5 to 100 VAC |
3 to 264 VAC,3 to 125 VAC |
100µA to 0.6A |
6A (10ms) |
|
Characteristics
| Operate time(see note) |
6 ms max. |
| Release time(see note) |
10 ms max. |
| Output ON-resistance(see note) |
2.4Ω max. |
| Leakage current |
10µA max(at 125 VDC) |
Insulation resistance |
100MΩ min.(at 500 VDC) |
| Dlelectric strength |
2,500 VAC, 50/60 Hz for 1min between input and output |
| Vibration resistance |
Malfunction:10 to 55Hz, 1.5mm double amplitude |
| Shock resistance |
Malfunction:1,000m/s2 |
Ambient
temperature |
Operating: -30ºC to 85ºC(with no icing or condensation)
Storage: -30ºC to 100ºC(with no icing or condensation) |
| Approved standards |
UL508 File No. E64562
CSA C22,2(No.14) File No.LR35535 |
| Ambient humidity |
Operating:45% to 85% |
| Weight |
Approx.3.1g |
| Note: |
These values are under the measurement conditions whereby rated voltages are applied to the input. |
Characteristics
Note: All units are milimeters unless otherwise indicated
|
 |
 |
 |
|