Mass Flow SensorD6F-P MEMS Flow SensorA Compact, High-performance Flow
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|
Updated March 23, 2009
|
| PCB mounting type | D6F-P0010A1 |
| Connector | D6F-P0010A2 |
| Power Supply Voltage | Vcc | 10 | VDC |
| Output Voltage | Vout | 4 | VDC |
|
|||||
|---|---|---|---|---|---|
| Flow rate | 0 to 1 L/min | ||||
| Joints | Barb joint (Inside diameter: 2.5 mm, Maximum external diameter: 4.9 mm, Minimum external diameter: 4 mm) |
||||
| Case material | Thermoplastic resin | ||||
| Applicable fluid | Air | ||||
| Operating conditions |
Operating temperature |
−10 to 60°C (with no condensation or icing) | |||
| Operating humidity |
85% max. (with no condensation or icing) | ||||
| Storage temperature |
−40 to 80°C (with no condensation or icing) | ||||
| Storage humidity | 85% max. (with no condensation or icing) | ||||
| Power supply voltage | 4.75 to 5.25 VDC | ||||
| Output signal | 0.5 to 2.5 VDC | ||||
| Output voltage accuracy | ±5% F.S. | ||||
| Fluctuation due to temperature characteristics |
±5% F.S. (−10 to 60°C) | ||||
| Current consumption | Without load: Vcc = 5.0 VDC, 15 mA max. | ||||
| Insulation resistance | Between Sensor outer cover and lead terminals: 20 MΩ min. (at 500 VDC) |
||||
| Withstand voltage | Between Sensor outer cover and lead terminals: 500 VAC, 50/60 Hz min. for 1 min (leakage current: 1 mA max.) |
||||
| (Unit :mm) PCB mounting type D6F-P0010A1 |
||
![]() |
||
Detailed View of A![]() |
Recommended Dimensions for Connector Mounting Holes ![]() |
|
| Soldering Conditions When using a soldering gun, heat for 3 s maximum with the soldering gun tip at 350°C ±10°C. Note: Be careful to not allow flux to get inside of the Sensor. |
||
|
Connector type D6F-P0010A2 |
||||||||||||||||
![]() |
||||||||||||||||
Detailed View of A![]() |
||||||||||||||||
|
||||||||||||||||
| Lead Wire(Accessory) D6F-CABLE2 ![]() |
||||||||||||||||