Power Relays

Search by product list
G6RN PCB Relay
Heavy-duty Miniature Relay
  • Incorporates environment-friendly, cadmium-free contacts.
  • Variety of contact forms: SPDT or SPST-NO (continuous current rating: 8 A)
  • Mechanical and electrical characteristics comply with VDE0435.
  • Satisfies VDE0700 requirements with a dielectric strength of 4 kV at a distance of 8 mm.
  • Satisfies C/250 insulation requirements of VDE0110.
  • Tracking resistance: CTI > 250
  • Conforms to class II, part 1 of VDE0106.
G6RN
JPN
OrderingInformationRatings / CharacteristicsDimensions
Classification
Enclosure ratings
Contact material
Contact form
SPST-NO
SPDT
Standard Fully sealed AgNi + gold plating (0.35 μ) G6RN-1A G6RN-1
AgCdO + gold plating (0.35 μ) G6RN-1A-ACD G6RN-1-ACD
AgCdO G6RN-1A-CDM G6RN-1-CDM
AgNi + gold plating (4 μ) G6RN-1A-AP4 G6RN-1-AP4
Note: When ordering, add the rated coil voltage to the model number.
Example: G6RN-1A
OrderingInformationRatings / CharacteristicsDimensions
Coil Ratings
Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC
Rated current 44 mA 18.3 mA 9.2 mA 5.2 mA
Coil resistance 114 Ω 655 Ω 2,620 Ω 9,210 Ω
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 110% of rated voltage at max. temperature (at 85ºC)
Power consumption Approx. 220 mW Approx. 250 mW
Note:1. The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23ºC.

Contact Ratings
Load Resistance load (cos φ = 1)
Rated load 8 A at 250 VAC,: 5 A at 30 VDC
Rated carry current 8 A
Max. switching voltage 250 VAC, 30 VDC, (400 VAC) (see note)
Max. switching current AC 8 A, DC 5 A
Max. switching power 2,000 VA, 150 W
Failure rate (reference value) 10 mA at 5 VDC (for gold plating 0.35 μ min.)
Note: Electrical life expectancy is reduced.

Characteristics
Operate time Approx. 6 ms
Release time Approx. 3 ms
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 360 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC between coil and contacts
1,000 VAC between contacts
Creepage/clearance 8 mm min. between coil and contacts
Vibration resistance
Malfunction: NO: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)

NC: 10 to 55 to 10 Hz, 0.4-mm single amplitude (0.8-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Endurance Mechanical: 10,000,000 operations min.
Electrical: Approx. 100,000 operations
Ambient temperature Operating: -40ºC to 85ºC (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 9 g
Protection class II according to VDE0106 Part 1
Insulation class C/250, B/380 according to VDE0110
OrderingInformationRatings / CharacteristicsDimensions
Note: All units are in millimeters unless otherwise indicated.

SPDT Type
G6RN:Dimensions1
Terminal Arrangement /
Internal Connections

(BOTTOM VIEW)
G6RN:Dimensions3
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1

G6RN:Dimensions2

SPST-NO Type

G6RN:Dimensions4
Terminal Arrangement /
Internal Connections

(BOTTOM VIEW)
G6RN:Dimensions6
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1

G6RN:Dimensions5