Power Relays
G6RN PCB Relay
Heavy-duty Miniature Relay
- Incorporates environment-friendly, cadmium-free contacts.
- Variety of contact forms: SPDT or SPST-NO (continuous current rating: 8 A)
- Mechanical and electrical characteristics comply with VDE0435.
- Satisfies VDE0700 requirements with a dielectric strength of 4 kV at a distance of 8 mm.
- Satisfies C/250 insulation requirements of VDE0110.
- Tracking resistance: CTI > 250
- Conforms to class II, part 1 of VDE0106.
|
|
| Classification |
Enclosure ratings |
Contact material |
Contact form |
| SPST-NO |
SPDT |
| Standard |
Fully sealed |
AgNi + gold plating (0.35 μ) |
G6RN-1A |
G6RN-1 |
| AgCdO + gold plating (0.35 μ) |
G6RN-1A-ACD |
G6RN-1-ACD |
| AgCdO |
G6RN-1A-CDM |
G6RN-1-CDM |
| AgNi + gold plating (4 μ) |
G6RN-1A-AP4 |
G6RN-1-AP4 |
| Note: |
When ordering, add the rated coil voltage to the model number.
Example: G6RN-1A  |
Coil Ratings
| Rated voltage |
5 VDC |
12 VDC |
24 VDC |
48 VDC |
| Rated current |
44 mA |
18.3 mA |
9.2 mA |
5.2 mA |
| Coil resistance |
114 Ω |
655 Ω |
2,620 Ω |
9,210 Ω |
| Must operate voltage |
70% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
110% of rated voltage at max. temperature (at 85ºC) |
| Power consumption |
Approx. 220 mW |
Approx. 250 mW |
| Note:1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| 2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
Contact Ratings
| Load |
Resistance load (cos φ = 1) |
| Rated load |
8 A at 250 VAC,: 5 A at 30 VDC |
| Rated carry current |
8 A |
| Max. switching voltage |
250 VAC, 30 VDC, (400 VAC) (see note) |
| Max. switching current |
AC 8 A, DC 5 A |
| Max. switching power |
2,000 VA, 150 W |
| Failure rate (reference value) |
10 mA at 5 VDC (for gold plating 0.35 μ min.) |
Note: Electrical life expectancy is reduced. Characteristics
| Operate time |
Approx. 6 ms |
| Release time |
Approx. 3 ms |
| Max. operating frequency |
Mechanical: 36,000 operations/hr Electrical: 360 operations/hr (under rated load) |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
4,000 VAC between coil and contacts 1,000 VAC between contacts |
| Creepage/clearance |
8 mm min. between coil and contacts |
| Vibration resistance |
| Malfunction: |
NO: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
|
NC: |
10 to 55 to 10 Hz, 0.4-mm single amplitude (0.8-mm double amplitude) |
|
| Shock resistance |
Destruction: 1,000 m/s2 |
| Endurance |
Mechanical: 10,000,000 operations min. Electrical: Approx. 100,000 operations |
| Ambient temperature |
Operating: -40ºC to 85ºC (with no icing) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 9 g |
| Protection class |
II according to VDE0106 Part 1 |
| Insulation class |
C/250, B/380 according to VDE0110 |
|