Power Relays
G6RL PCB Relay
Low-profile power relay with maximum
switching of 10 A
- Low profile: 12.3 mm in height
- Max. switching capacity: 2,500 VA (NO)
- Dielectric strength: 5 kV
- Clearance and creepage distance: 10 mm.
- Models with high shock resistance (250 m/s2) are available.
- Models for P1 load (2 × 200 W lamps parallel to ignition transformer) are available.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
Enclosure rating |
Contact form |
Contact material |
| AgSnIn |
AgNi |
| Standard |
Flux protection |
SPST-NO |
G6RL-1A-ASI |
G6RL-1A |
| SPDT |
G6RL-1-ASI |
G6RL-1 |
| Fully sealed |
SPST-NO |
G6RL-1A4-ASI |
--- |
| SPDT |
G6RL-14-ASI |
--- |
| P1 Load |
Flux protection |
SPST-NO |
G6RL-1A-ASI-PL |
--- |
| SPDT |
G6RL-1-ASI-PL |
--- |
| Shock resistance |
Flux protection |
SPST-NO |
--- |
--- |
| SPDT |
G6RL-1-SR-ASI |
--- |
| Fully sealed |
SPST-NO |
--- |
--- |
| SPDT |
G6RL-14-SR-ASI |
--- |
| Note: |
When ordering, add the rated coil voltage to the model number.
Example: G6RL-1A  |
Coil Ratings
| Classification |
Standard, P1 load |
| Rated voltage |
3 VDC |
5 VDC |
6 VDC |
12 VDC |
24 VDC |
48 VDC |
| Rated current |
73.3 mA |
44.0 mA |
36.7 mA |
18.3 mA |
9.2 mA |
5.0 mA |
| Coil resistance |
40 Ω |
113 Ω |
163 Ω |
654 Ω |
2,618 Ω |
9,600 Ω |
| Must operate voltage |
70% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
150% of rated voltage |
| Power consumption |
Approx. 220 mW |
Approx. 240 mW |
| Classification |
Shock resistance |
| Rated voltage |
3 VDC |
5 VDC |
6 VDC |
12 VDC |
24 VDC |
| Rated current |
101 mA |
60.2 mA |
50.1 mA |
25.2 mA |
12.6 mA |
| Coil resistance |
30 Ω |
83 Ω |
120 Ω |
476 Ω |
1,912 Ω |
| Must operate voltage |
80% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
150% of rated voltage(23ºC) |
| Power consumption |
Approx. 300 mW |
| Note: |
1. |
The above items are measured at a coil temperature of 23ºC. |
| |
2. |
The tolerance of the rated current is ±10%. |
Contact Ratings
| Load |
Resistive load (cos φ = 1) |
| Rated load (see note 1.) |
10 A at 250 VAC, NO resistive load
8 A at 250 VAC, resistive load
5 A at 30 VDC, resistive load |
| Rated carry current |
10 A at 250 VAC
5 A at 30 VDC |
| Max. switching voltage |
400 VAC, 300 VDC |
| Max. switching current |
NO: 10 A, NC: 8 A |
| Max. switching power |
NO: 2,500 VA, NC: 2,000 VA
150 W |
| Failure rate (reference value) |
10 mA at 5 VDC (P Level) (see note 2. ) |
| note: |
1. |
G6RL-1(A), G6RL-1(A)4-ASI: 8 A 250 VAC, resistive load; 5 A 24 VDC resistive load. |
| |
2. |
P level: λ 60 = 0.1 × 10-6 / operations |
Characteristics
| Contact resistance |
100 mΩ max. |
| Operate time |
10 ms max.(SR Models : 15 ms max.) |
| Release time |
5 ms max. |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
5,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
SR Models: 250 ms2 (NO and NC) when not energized |
| Impulse withstand voltage |
10 kV between coil and contacts (1.2 × 50 µs) |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 1.5-mm double amplitude |
| Malfunction: |
10 to 55 to 10 Hz, 0.825-mm single amplitude
(1.65-mm double amplitude) when energized.
10 to 55 to 10 Hz, 0.4-mm single amplitude
(0.8-mm double amplitude) when not energized. |
|
| Shock resistance |
Destruction: 1,000 m/s2
Malfunction: 200 m/s2 NO, 50 m/s2 NC when not energized
SR Models: 250 ms2 (NO and NC) when not energized |
| Endurance (Mechanical) |
10,000,000 operations min. (at 18,000 operations/h) |
| Ambient temperature |
Operating: -40ºC to 85ºC (with no icing) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 7.8 g |
Other data
| Construction of protection |
Flux protection |
Fully sealed |
| Insulation material group |
IIIa |
| Rated insulation voltage |
250 V |
| Pollution degree |
3 |
2 |
| Rated voltage system |
250 V |
400 V |
| Over-voltage category |
III |
| Creepage distance |
10 mm |
| Clearance distance |
10 mm |
| RoHS |
Compliant |
| Tracking index of relay base |
PTI 250 |
Flammability class according
to UL94 |
V-0 |
Flammability-flame
GWFI (IEC 60695-2-12)
GWIT (IEC 60695-2-13) |
|
Ball pressure test
(IEC 60695-10-2) |
170ºC |
|
Relays