G6RL PCB Relay

Low-profile power relay with maximum switching of 10 A

  • Low profile: 12.3 mm in height
  • Max. switching capacity: 2,500 VA (NO)
  • Dielectric strength: 5 kV
  • Clearance and creepage distance: 10 mm.
  • Models with high shock resistance (250 m/s2) are available.
  • Models for P1 load (2 × 200 W lamps parallel to ignition transformer) are available.
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Classification Enclosure rating Contact form Contact material
AgSnIn AgNi
Standard Flux protection SPST-NO G6RL-1A-ASI G6RL-1A
SPDT G6RL-1-ASI G6RL-1
Fully sealed SPST-NO G6RL-1A4-ASI ---
SPDT G6RL-14-ASI ---
P1 Load Flux protection SPST-NO G6RL-1A-ASI-PL ---
SPDT G6RL-1-ASI-PL ---
Shock resistance Flux protection SPST-NO --- ---
SPDT G6RL-1-SR-ASI ---
Fully sealed SPST-NO --- ---
SPDT G6RL-14-SR-ASI ---
Note: When ordering, add the rated coil voltage to the model number.
Example: G6RL-1A
OrderingInformationRatings / CharacteristicsDimensions
Coil Ratings
Classification Standard, P1 load
Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC
Rated current 73.3 mA 44.0 mA 36.7 mA 18.3 mA 9.2 mA 5.0 mA
Coil resistance 40 Ω 113 Ω 163 Ω 654 Ω 2,618 Ω 9,600 Ω
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 150% of rated voltage
Power consumption Approx. 220 mW Approx. 240 mW


Classification Shock resistance
Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC
Rated current 101 mA 60.2 mA 50.1 mA 25.2 mA 12.6 mA
Coil resistance 30 Ω 83 Ω 120 Ω 476 Ω 1,912 Ω
Must operate voltage 80% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 150% of rated voltage(23ºC)
Power consumption Approx. 300 mW
Note: 1. The above items are measured at a coil temperature of 23ºC.
  2. The tolerance of the rated current is ±10%.

Contact Ratings
Load Resistive load (cos φ = 1)
Rated load (see note 1.) 10 A at 250 VAC, NO resistive load
8 A at 250 VAC, resistive load
5 A at 30 VDC, resistive load
Rated carry current 10 A at 250 VAC
5 A at 30 VDC
Max. switching voltage 400 VAC, 300 VDC
Max. switching current NO: 10 A, NC: 8 A
Max. switching power NO: 2,500 VA, NC: 2,000 VA
150 W
Failure rate (reference value) 10 mA at 5 VDC (P Level) (see note 2. )
note: 1. G6RL-1(A), G6RL-1(A)4-ASI: 8 A 250 VAC, resistive load; 5 A 24 VDC resistive load.
  2. P level: λ 60 = 0.1 × 10-6 / operations


Characteristics
Contact resistance 100 mΩ max.
Operate time 10 ms max.(SR Models : 15 ms max.)
Release time 5 ms max.
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
SR Models: 250 ms2 (NO and NC) when not energized
Impulse withstand voltage 10 kV between coil and contacts (1.2 × 50 µs)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 to 10 Hz, 0.825-mm single amplitude
(1.65-mm double amplitude) when energized.
10 to 55 to 10 Hz, 0.4-mm single amplitude
(0.8-mm double amplitude) when not energized.
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 NO, 50 m/s2 NC when not energized
SR Models: 250 ms2 (NO and NC) when not energized
Endurance (Mechanical) 10,000,000 operations min. (at 18,000 operations/h)
Ambient temperature Operating: -40ºC to 85ºC (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 7.8 g


Other data
Construction of protection Flux protection Fully sealed
Insulation material group IIIa
Rated insulation voltage 250 V
Pollution degree 3 2
Rated voltage system 250 V 400 V
Over-voltage category III
Creepage distance 10 mm
Clearance distance 10 mm
RoHS Compliant
Tracking index of relay base PTI 250
Flammability class according
to UL94
V-0
Flammability-flame
GWFI (IEC 60695-2-12)
GWIT (IEC 60695-2-13)
850ºC
750ºC
Ball pressure test
(IEC 60695-10-2)
170ºC
OrderingInformationRatings / CharacteristicsDimensions
Note: All units are in millimeters unless otherwise indicated.

G6RL-1A(-ASI)
G6RL-1A4(-ASI)

G6RN:Dimensions1
Terminal Arrangement /
Internal Connections

(BOTTOM VIEW)
G6RN:Dimensions3
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1

G6RN:Dimensions2
Note: Indicates average dimensions.

G6RL(-ASI)
G6RL-14(-ASI)

G6RN:Dimensions4
Terminal Arrangement /
Internal Connections

(BOTTOM VIEW)
G6RN:Dimensions6
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1

G6RN:Dimensions5
Note: Indicates average dimensions.
Related Links
Technology
Application Guide