Relays
Sensors
Foundry
By Part# / Name
By Category
Switches
Micro Sensing Devices
Facial Image Sensing Technology
Connectors
Optical Communication Devices

Power Relays

Search by product list

G6D PCB Relay

Slim, Miniature Relay, Capable of Relaying Programmable Controller and Temperature Controller Outputs

  • Slim and miniature: 17.5 × 6.5 × 12.5 mm(L × W × H).
  • Ideal for high-density mounting.
  • Switches 5 A at 250 VAC/30 VDC.
  • Allows 300,000 operations with a 2-A load at 250 VAC or 30 VDC.
  • Actual load switching capability equals the G6B's capability.
  • Washable construction.
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Classification
Contact form
Enclosure ratings
Model
Standard SPST-NO Fully sealed G6D-1A-ASI
Note: When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI
OrderingInformationRatings / CharacteristicsDimensions
Coil Ratings
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 40 mA 16.7 mA 8.3 mA
Coil resistance 125 Ω 720 Ω 2,880 Ω
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 160% of rated voltage (at 23ºC)
Power consumption Approx. 200 mW
Note: The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.

Contact Ratings
Rated load 5 A at 250 VAC, 5 A at 30 VDC, resistive load
Rated carry current 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A
Max. switching power 1,250 VA, 150 W
Failure rate (reference value) 10 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10-6/operation

Characteristics
Contact resistance 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 6,000 V (1.2 x 50 μs) between coil and contacts
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Endurance
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 70,000 operations min. (5 A at 250 VAC/30 VDC, resistive load)
300,000 operations min. (2 A at 250 VAC/30 VDC, resistive load)
Ambient temperature Operating: -25ºC to 70ºC (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 3 g
OrderingInformationRatings / CharacteristicsDimensions
Note: 1. All units are in millimeters unless otherwise indicated.
  2. Orientation marks are indicated as follows:

G6D-1A-ASI
G6D:Dimensions1
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1

G6D:Dimensions2

Terminal Arrangement /
Internal Connections

(BOTTOM VIEW)
G6D:Dimensions3

P6D-04P Socket
G6D:Dimensions4
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1

G6D:Dimensions5
Related Links
Technology
Application Guide