Power Relays
G6D PCB Relay
Slim, Miniature Relay, Capable of Relaying Programmable Controller and Temperature Controller Outputs
- Slim and miniature: 17.5 × 6.5 × 12.5 mm(L × W × H).
- Ideal for high-density mounting.
- Switches 5 A at 250 VAC/30 VDC.
- Allows 300,000 operations with a 2-A load at 250 VAC or 30 VDC.
- Actual load switching capability equals the G6B's
capability.
- Washable construction.
 |
|
|
|
Updated June 14, 2010
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
Classification |
Contact form |
Enclosure ratings |
Model |
| Standard |
SPST-NO |
Fully sealed |
G6D-1A-ASI |
| Note: |
When ordering, add the rated coil voltage to the model number. Example: G6D-1A-ASI |
Coil Ratings
| Rated voltage |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
40 mA |
16.7 mA |
8.3 mA |
| Coil resistance |
125 Ω |
720 Ω |
2,880 Ω |
| Must operate voltage |
70% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
160% of rated voltage (at 23ºC) |
| Power consumption |
Approx. 200 mW |
| Note: |
The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. |
Contact Ratings
| Rated load |
5 A at 250 VAC, 5 A at 30 VDC, resistive load |
| Rated carry current |
5 A |
| Max. switching voltage |
250 VAC, 30 VDC |
| Max. switching current |
5 A |
| Max. switching power |
1,250 VA, 150 W |
| Failure rate (reference value) |
10 mA at 5 VDC |
Note: P level: λ60 = 0.1 x 10-6/operation Characteristics
| Contact resistance |
100 mΩ max. |
| Operate time |
10 ms max. |
| Release time |
5 ms max. |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
3,000 VAC, 50/60 Hz for 1 min between coil and contacts 750 VAC, 50/60 Hz for 1 min between contacts of same polarity |
| Impulse withstand voltage |
6,000 V (1.2 x 50 μs) between coil and contacts |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Malfunction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
|
| Shock resistance |
Destruction: 1,000 m/s2 Malfunction: 100 m/s2 |
| Endurance |
| Mechanical: |
20,000,000 operations min. (at 18,000 operations/hr) |
| Electrical: |
70,000 operations min. (5 A at 250 VAC/30 VDC,
resistive load) 300,000 operations min. (2 A at 250 VAC/30 VDC, resistive load) |
|
| Ambient temperature |
Operating: -25ºC to 70ºC (with no icing) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 3 g |
|