PCB Power Relays

G5Q PCB Power Relay

A Miniature Power Relay with 1-pole 10A Switching Capacity

  • Compact single pole relay.
  • Excellent switching performance for a variety of loads.
  • Small, yet provide 8-kV impulse withstand voltage (between coil and contacts).
  • Low coil power consumption (SPST-NO: 200 mW, SPDT: 400 mW)
  • Coil insulation system: Class F (UL1446).
  • IEC/EN 60335-1 conformed. (-HA Model)

Updated Feb. 26, 2014

This web page provides an excerpt from a datasheet. Refer to Datasheet and other applicable documents for more information.

Terminal Shape Market Code Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit
PCB terminals General purpose Standard SPST-NO (1a) Flux protection G5Q-1A 5VDC
9VDC
12VDC
24VDC
40 pcs/tube
Sealed G5Q-1A4
SPDT (1c) Flux protection G5Q-1
Sealed G5Q-14
High-capacity SPST-NO (1a) Flux protection G5Q-1A-EU 5VDC
12VDC
24VDC
Sealed G5Q-1A4-EU
SPDT (1c) Flux protection G5Q-1-EU
Sealed G5Q-14-EU
Home Appliance SPST-NO (1a) Flux protection G5Q-1A-EU-HA 12VDC
24VDC
SPDT (1c) G5Q-1-EU-HA
Coil Ratings
Contact
form
Item

Rated voltage (V)
Ratedcurrent
(mA)
Coil
resistance
(Ω)
Must-operate
voltage
(V)
Must-release
voltage
(V)
Max. voltage
(V)
Power
consumption
(mW)
SPST-NO (1a) 5 VDC 40 125 75% max. 5% min. 190%
(at 23ºC)
Approx. 200
9 VDC 22.2 405
12 VDC 16.7 720
24 VDC 8.3 2880
SPDT (1c) 5 VDC 80 63 Approx. 400
9 VDC 44.4 202
12 VDC 33.3 360
24 VDC 16.7 1440
Note: 1. The rated voltage and coil resistance are given at a coil temperature of 23ºC and with a tolerance of ±10%.
  2. The operating characteristics are given at a coil temperature of 23ºC.
  3. The maximum voltage is the maximum voltage that can be applied to the relay coil.

Contact
Item Load Resistive load
SPST-NO (1a) SPDT (1c)
Standard High-capacity Standard High-capacity
Contact mechanism Single
Contact material Ag-alloy (Cd free)
Rated load 10 A at 125 VAC
3 A at 125 VAC
3 A at 250 VAC
5 A at 30 VDC
10 A at 250 VAC
3 A at 125 VAC
3 A at 250 VAC
5 A at 30 VDC
10 A at 125 VAC (NO)
3 A at 125 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 250 VAC (NC)
3 A at 30 VDC (NC)
10 A at 250 VAC (NO)
3 A at 125 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 250 VAC (NC)
3 A at 30 VDC (NC)
Rated carry current 10 A (NO)/3 A (NC)
Max. switching voltage 277 VAC, 30 VDC
Max. switching current AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)

Characteristics
Item Type
Standard models
Contact resistance *1 100mΩ max.
Operate time 10ms max.
Release time 5ms max.
Insulation resistance *2 1,000 mΩmin.
Dielectric strength Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage (between coil and contacts) 8kV(1.2×50μs)
Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Shock resistance Destruction 1,000m/s2
Malfunction 100m/s2
Endurance Mechanical 10,000,000 operations (18,000 operations per hour)
Electrical
· NO  
  25,000 operations: 10 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 3 sec) < High-capacity type >
50,000 operations: 10 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 3 sec)
200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 5 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
· NC  
  200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
Failure rate (P level) (reference *3) 10 mA at 5 VDC
Ambient operating temperature -40ºC to 105ºC (with no icing or condensation)
-40°C to 85°C (with no icing or condensation) < High-capacity type >
Ambient operating humidity 5% to 85% (with no icing or condensation)
Weight Approx. 6.5 g
NOTE:   Note. Values in the above table are the initial values at 23°C.
  1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
  2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.
  3. This value was measured at a switching frequency of 120 operations/min.
Note:1. All units are in millimeters unless otherwise indicated.

G5Q-1A
G5Q-1A4
G5Q-1A-EU (-HA)
G5Q-1A4-EU

G5Q-1:gaikei1
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm

G5Q-1:gaikei2
Terminal Arrangement/
Internal Connections

(BOTTOM VIEW)
G5Q-1:gaikei1

G5Q-1
G5Q-14
G5Q-1-EU (-HA)
G5Q-14-EU

G5Q-1:gaikei1
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm

G5Q-1:gaikei5

Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)

G5Q-1:gaikei1

Back to top

Search OMRON Components

Select Your Area
close