Power Relays
G5Q PCB Relay
Compact, Single-pole, 10-A Switching
PCB Relays
- Compact, SPST-NO and SPDT relays.
- Excellent switching performance for a variety of
loads.
- Withstand impulse rating of 8,000 V between the
coil and contacts.
- UL class F coil insulation on all models.
- UL, CSA, and VDE approved.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
| Enclosure rating |
| Contact form |
|
Standard models |
Flux protection |
Fully sealed |
Rated coil voltage |
Model |
Rated coil voltage |
Model |
| SPST-NO |
5VDC |
G5Q-1A |
5VDC |
G5Q-1A4 |
9VDC
|
9VDC |
12VDC
|
12VDC |
24VDC
|
24VDC |
| SPDT |
5VDC |
G5Q-1 |
5VDC |
G5Q-14 |
9VDC
|
9VDC |
12VDC
|
12VDC |
24VDC
|
24VDC |
Coil Ratings
Contact form |
|
Rated
current
(mA) |
Coil
resistance
(Ω)
|
Must-operate
voltage
(V) |
Must-release
voltage
(V) |
Max. voltage
(V) |
Power
consumption
(mW) |
| SPST-NO |
VDC |
5 |
40 |
125 |
75% max. of rated voltage |
5% min. of rated voltage |
190% of rated voltage (at 23ºC) |
Approx. 200 |
| 9 |
22.2 |
405 |
| 12 |
16.7 |
720 |
| 24 |
8.3 |
2880 |
| SPDT |
5 |
80 |
63 |
Approx. 400 |
| 9 |
44.4 |
202 |
| 12 |
33.3 |
360 |
| 24 |
16.7 |
1440 |
| Note: |
1. |
The rated voltage and coil resistance are given at a coil temperature of 23ºC and with a tolerance of ±10%. |
| |
2. |
The operating characteristics are given at a coil temperature of 23ºC. |
| |
3. |
The maximum voltage is the maximum voltage that can be applied to the relay coil. |
Contact Ratings
| |
Resistive load |
SPST-NO |
SPDT |
| Contact mechanism |
Single |
| Contact material |
Ag alloy (Cd free) |
| Rated load |
10 A at 125 VAC 3 A at 250 VAC 5 A at 30 VDC |
10 A at 125 VAC (NO) 3 A at 250 VAC (NO) 5 A at 30 VDC (NO) 3 A at 125 VAC (NC) 3 A at 30 VDC (NC) |
| Rated carry current |
10 A (NO)/3 A (NC) |
| Max. switching voltage |
277 VAC, 30 VDC |
| Max. switching current |
AC: 10 A (NO)/3 A (NC) DC: 5 A (NO)/3 A (NC) |
Characteristics
|
Standard models |
| Contact resistance (See note 2.) |
100mΩ max. |
| Operate time |
10ms max. |
| Release time |
5ms max. |
| Insulation resistance (See note 3.) |
1,000mΩmin. |
| Dielectric strength |
Between coil and contacts |
4,000 VAC, 50/60 Hz for 1 min |
| Between contacts of same polarity |
1,000 VAC, 50/60 Hz for 1 min |
| Impulse withstand voltage (between coil and contacts)
|
8kV(1.2×50μs) |
| Vibration resistance |
Destruction |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Malfunction |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Shock resistance |
Destruction |
1,000m/s2 |
| Malfunction |
100m/s2 |
| Endurance |
Mechanical |
10,000,000 operations (18,000 operations per hour) |
| Electrical |
| 200,000 operations: |
3 A (NO)/3 A (NC) at 125 VAC, resistive load |
| 100,000 operations: |
3 A (NO)/3 A (NC) at 250 VAC, |
| |
5 A (NO)/3 A (NC) at 30 VDC, resistive load |
| 50,000 operations: |
10 A at 125 VAC (900 operations per hour) |
|
| Failure rate (reference value) (See note 4.) |
10 mA at 5 VDC |
| Ambient operating temperature range |
-40ºC to 85ºC (with no icing or condensation) |
| Ambient operating humidity range |
5% to 85% |
| Weight |
Approx. 6.5 g |
| Note: |
1. |
The data shown above are initial values. |
| |
2. |
The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. |
| |
3. |
The insulation resistance is measured at the same points as the dielectric strength using a 500-VDC ohmmeter. |
| |
4. |
P level: λ60=0.1 × 10-6/operation |
|
Relays