Power Relays
G5NB PCB Relay
A Miniature Relay with 1-pole 3-A Switching Capability and 10-kV Impulse Withstand Voltage
- Highly efficient magnetic circuit for high sensitivity (200 mW).
- Small, yet provides 10-kV impulse withstand voltage (between coil and contacts).
- Standard model conforms to UL and CSA and VDE standards.
 |
|
|
|
|
|
|
Updated April 18, 2011
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
Contact form |
Enclosure ratings |
Model |
| Standard |
SPST-NO |
Flux protection |
G5NB-1A |
| Note: |
When ordering, add the rated coil voltage to the model number. Example: G5NB-1A |
Coil Ratings
| Rated voltage |
5 VDC |
12 VDC |
18 VDC |
24 VDC |
| Rated current |
40.0 mA |
16.7 mA |
11.1 mA |
8.3 mA |
| Coil resistance |
125 Ω |
720 Ω |
1,620 Ω |
2,880 Ω |
| Must operate voltage |
75% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
180% of rated voltage (at 23ºC) |
| Power consumption |
Approx. 200 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
|
2. |
The operating characteristics are measured at a coil temperature of 23ºC. |
|
3. |
The “Max. voltage” is the maximum voltage that can be applied to the relay coil. |
Contact Ratings
| Load |
Resistive load (cosφ = 1) |
| Rated load |
3 A at 125 VAC, 3 A at 30 VDC |
| Max. switching voltage |
250 VAC, 30 VDC |
| Max. switching current |
3 A |
| Max. switching power |
375 VA, 90 W |
| Failure rate (reference value) |
10 mA at 5 VDC |
Note: P level: λ60 = 0.1 × 10-6operation
Characteristics
| Contact resistance (See note 2.) |
100 mΩ max. |
| Operate time |
10 ms max. |
| Release time |
10 ms max. |
| Insulation resistance (See note 3.) |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
4,000 VAC, 50/60 Hz for 1 min between coil and contacts 750 VAC, 50/60 Hz for 1 min between contacts of same polarity |
| Impulse withstand voltage |
10,000 V (1.2 x 50 μs)between coil and contacts |
| Vibration resistance |
| Destruction: |
10 to 55 Hz, 0.75-mm single amplitucle (1.5-mm double amplitude) |
| Malfunction: |
10 to 55 Hz, 0.75-mm single amplitucle (1.5-mm double amplitude) |
|
| Shock resistance |
Destruction: 1,000 m/s2 Malfunction: 100 m/s2 |
| Endurance |
Mechanical: 5,000,000 operations min. Electrical: 200,000 operations min. |
Failure rate P level (reference value) (See note 4.) |
5 VDC, 10 mA |
| Ambient temperature |
Operating: -40ºC to 70ºC (with no icing or condensation) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 4 g |
| Note: |
1. |
The data shown above are initial value. |
|
2. |
Measurement conditions: 5 VDC, 1 A, voltage drop method |
|
3. |
Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter. |
|
4. |
This value is for a switching frequency of 120 operations/minute. |
| Note: All units are in millimeters unless otherwise indicated. |
G5NB-1A
 |
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
 |
Terminal Arrangement / Internal Connections
(BOTTOM VIEW)
 (No coil polarity) |
|