Power Relays
G4A PCB Relay
Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current
- Ideal for motor switching.
- Miniature, relay with high switching power and long endurance.
- Creepage distance conforms to UL and CSA standards.
- Highly noise-resistive insulation materials employed.
- Standard model available with flux protection construction.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
Contact form |
Model |
| #250 tab terminals/PCB coil terminals |
SPST-NO |
G4A-1A-E |
| PCB terminals/PCB coil terminals |
G4A-1A-PE |
| Note: |
When ordering, add the rated coil voltage to the model number.
Example: G4A-1A-E 12VDC |
Coil Ratings
| Rated voltage |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
180 mA |
75 mA |
37.5 mA |
| Coil resistance |
27.8 Ω |
160 Ω |
640 Ω |
Coil inductance
(ref. value) |
Armature OFF |
--- |
0.8 H |
3.5 H |
| Armature ON |
--- |
1.1 H |
4.8 H |
| Must operate voltage |
70% of rated voltage max. |
| Must release voltage |
10% of rated voltage min. |
| Max. permissible voltage |
160% of rated voltage at (23ºC) |
| Power consumption |
Approx. 0.9 W |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
| |
3. |
Max. permissible voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. |
Contact Ratings
| Rated load |
20 A at 250 VAC |
| Rated carry current |
20 A |
| Max. switching voltage |
250 VAC |
| Max. switching current |
20 A |
| Max. switching power |
5,000 VA |
| Failure rate (reference value) |
100 mA at 5 VDC |
| Note: |
P level: λ60 = 0.1 × 10-6/operation (with an operating frequency of 120 operations/min) |
Endurance
With Motor Load
| Load conditions |
Switching frequency |
Electrical endurance |
250 VAC:
Inrush current: 80 A, 0.3 s (cosφ= 0.7)
Break current: 20 A (cosφ = 0.9) |
ON: 1.5 s
OFF:1.5 s |
200,000 operations |
With Overload
| Load conditions |
Switching frequency |
Electrical endurance |
250 VAC:
Inrush current: 80 A (cosφ= 0.7)
Break current: 80 A (cosφ = 0.7) |
ON: 1.5 s OFF:99 s |
1,500 operations |
With Inverter Load
| Load conditions |
Switching frequency |
Electrical endurance |
100 VAC:
Inrush current: 200 A (0-P)
Break current: 20 A |
ON: 3 s
OFF:5 s |
30,000 operations |
Characteristics
| Contact resistance |
100 mΩ max. |
| Operate time |
20 ms max. |
| Release time |
10 ms max. |
| Max. operating frequency |
Mechanical: 18,000 operations/hr |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
4,500 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Malfunction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
|
| Shock resistance |
Destruction: 1,000 m/s2
Malfunction: 200 m/s2 |
| Endurance |
| Mechanical: |
2,000,000 operations min. (at 18,000 operations/hr) |
| Motor load: |
100,000 operations min. (ON/OFF: 1.5 s) |
| Inverter load: |
30,000 operations min. (ON: 3 s, OFF: 5 s) |
|
| Ambient temperature |
Operating: -20ºC to 60ºC (with no icing) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 25 g |
Note: The data shown above are initial values.
|
Relays
Product Lineup
Support
Related Links


|