Relays
Sensors
Facial Image Sensing Technology
By Part# / Name
By Category
Switches
Micro Sensing Devices
Connectors
Foundry

Power Relays

Search by product list

G2RL PCB Relay

A Power Relay with Various Models

  • High-sensitivity (250 mW) and High-capacity (16 A) Models available.
  • Low profile: 15.7 mm max. in height
  • Conforms to VDE (EN61810-1), UL508 and CSA22.2.
  • Meets EN60335-1 requirements for household products.
  • Clearance and creepage distance: 10 mm/10 mm.
  • Tracking resistance: CTI>250
  • Coil Insulation system: Class F (UL1446)
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Classification Enclosure
ratings
Contact form
SPST-NO SPDT DPST-NO DPDT
General-purpose Flux protection G2RL-1A G2RL-1 G2RL-2A G2RL-2
Fully sealed G2RL-1A4 G2RL-14 G2RL-2A4 G2RL-24
High-capacity Flux protection G2RL-1A-E G2RL-1-E --- ---
Fully sealed G2RL-1A4-E G2RL-14-E --- ---
High-sensitivity Flux protection G2RL-1A-H G2RL-1-H --- ---
Note: When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A
OrderingInformationRatings / CharacteristicsDimensions
Coils Ratings for General-purpose and High-capacity Models
Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC
Rated current 80.0 mA 33.3 mA 16.7 mA 8.96 mA
Coil resistance 62.5 Ω 360 Ω 1,440 Ω 5,358 Ω
Must operate voltage 70% max. of the rated voltage
Must release voltage 10% min. of the rated voltage
Max. voltage 180% of rated voltage (at 23°C)
Power consumption Approx. 400 mW Approx. 430 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.

Coils Ratings for High-sensitivity Models
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 50.0 mA 20.8 mA 10.42 mA
Coil resistance 100 Ω 576 Ω 2,304 Ω
Must operate voltage 75% max. of the rated voltage
Must release voltage 10% min. of the rated voltage
Max. voltage 180% of rated voltage (at 23°C)
Power consumption Approx. 250 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.

Contact Ratings
Item General-purpose Models High-capacity Models High-sensitivity Models
Number of poles 1 pole 2 poles 1 pole 1 pole
Contact material Ag Alloy (Cd free)
Load Resistive load (cosφ=1)
Rated load 12 A at 250 VAC
12 A at 24 VDC
(See note.)
8 A at 250 VAC
8 A at 30 VDC
(See note.)
16 A at 250 VAC
16 A at 24 VDC
(See note.)
10 A at 250 VAC
10 A at 24 VDC
(See note.)
Rated carry current 12 A
(See note.)
8 A (70°C)/5 A (85°C)
(See note.)
16 A
(See note.)
10 A
(See note.)
Max. switching voltage 440 VAC, 300 VDC
Max. switching current 12 A 8 A 16 A 10 A
Max. switching power 3,000 VA 2,000 VA 4,000 VA 2,500 VA
Note: Contact your OMRON representative for the ratings on fully sealed models.

Characteristics
Item General-purpose
(High-capacity) Models
General-purpose Models High-sensitivity Models
Number of poles 1 pole 2 poles 1 pole
Contact resistance 100 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time 5 ms max.
Max. operating frequency Mechanical:18,000 operation/hr
Electrical:1,800 operation/hr at rated load
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 1 min between coil and contacts
1,000 VAC, 1 min between contacts of same polarity
5,000 VAC, 1 min between coil and contacts
2,500 VAC, 1 min between contacts of different polarity
1,000 VAC, 1 min between contacts of same polarity
5,000 VAC, 1 min between coil and contacts
1,000 VAC, 1 min between contacts of same polarity
Impulse withstand voltage 10 kV (1.2×50 μs) between coil and contact
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2 (approx. 100 G)
Malfunction: 100 m/s2 (approx. 10 G)
Endurance (Mechanical) 20,000,000 operations (at 18,000 operations/hr)
Ambient temperature Operating: –40°C to 85°C (with no icing)
Storage: –40°C to 85°C (with no icing)
Ambient humidity 5% to 85%
Weight Approx. 12 g
Note: Values in the above table are the initial values.
OrderingInformationRatings / CharacteristicsDimensions
Note: All units are in millimeters unless otherwise indicated.
G2RL-1A(-H), G2RL-1A4

*Indicates average dimensions.
Terminal Arrangement/Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)


G2RL-1(-H), G2RL-14

*Indicates average dimensions.
Terminal Arrangement/Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)


G2RL-1A-E, G2RL-1A4-E

*Indicates average dimensions.
Terminal Arrangement/Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)


G2RL-1-E, G2RL-14-E

*Indicates average dimensions.
Terminal Arrangement/Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)


G2RL-2A, G2RL-2A4

*Indicates average dimensions.
Terminal Arrangement/Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)


G2RL-2, G2RL-24

*Indicates average dimensions.
Terminal Arrangement/Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)

Related Links
Technology
Application Guide