Power Relays
G2RL PCB Relay
A Power Relay with Various Models
- High-sensitivity (250 mW) and High-capacity (16 A) Models available.
- Low profile: 15.7 mm max. in height
- Conforms to VDE (EN61810-1), UL508 and CSA22.2.
- Meets EN60335-1 requirements for household products.
- Clearance and creepage distance: 10 mm/10 mm.
- Tracking resistance: CTI>250
- Coil Insulation system: Class F (UL1446)
 |
|
|
|
(G2RL)
|
|
(G2RL-1-E)
|
|
|
|
Updated June 6, 2011
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
Enclosure
ratings |
Contact form |
| SPST-NO |
SPDT |
DPST-NO |
DPDT |
| General-purpose |
Flux protection |
G2RL-1A |
G2RL-1 |
G2RL-2A |
G2RL-2 |
| Fully sealed |
G2RL-1A4 |
G2RL-14 |
G2RL-2A4 |
G2RL-24 |
| High-capacity |
Flux protection |
G2RL-1A-E |
G2RL-1-E |
--- |
--- |
| Fully sealed |
G2RL-1A4-E |
G2RL-14-E |
--- |
--- |
| High-sensitivity |
Flux protection |
G2RL-1A-H |
G2RL-1-H |
--- |
--- |
| Note: |
When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A |
Coils Ratings for General-purpose and High-capacity Models
| Rated voltage |
5 VDC |
12 VDC |
24 VDC |
48 VDC |
| Rated current |
80.0 mA |
33.3 mA |
16.7 mA |
8.96 mA |
| Coil resistance |
62.5 Ω |
360 Ω |
1,440 Ω |
5,358 Ω |
| Must operate voltage |
70% max. of the rated voltage |
| Must release voltage |
10% min. of the rated voltage |
| Max. voltage |
180% of rated voltage (at 23°C) |
| Power consumption |
Approx. 400 mW |
Approx. 430 mW |
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Coils Ratings for High-sensitivity Models
| Rated voltage |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
50.0 mA |
20.8 mA |
10.42 mA |
| Coil resistance |
100 Ω |
576 Ω |
2,304 Ω |
| Must operate voltage |
75% max. of the rated voltage |
| Must release voltage |
10% min. of the rated voltage |
| Max. voltage |
180% of rated voltage (at 23°C) |
| Power consumption |
Approx. 250 mW |
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Contact Ratings
| Item |
General-purpose Models |
High-capacity Models |
High-sensitivity Models |
| Number of poles |
1 pole |
2 poles |
1 pole |
1 pole |
| Contact material |
Ag Alloy (Cd free) |
| Load |
Resistive load (cosφ=1) |
| Rated load |
12 A at 250 VAC
12 A at 24 VDC
(See note.) |
8 A at 250 VAC
8 A at 30 VDC
(See note.) |
16 A at 250 VAC
16 A at 24 VDC
(See note.) |
10 A at 250 VAC
10 A at 24 VDC
(See note.) |
| Rated carry current |
12 A
(See note.) |
8 A (70°C)/5 A (85°C)
(See note.) |
16 A
(See note.) |
10 A
(See note.) |
| Max. switching voltage |
440 VAC, 300 VDC |
| Max. switching current |
12 A |
8 A |
16 A |
10 A |
| Max. switching power |
3,000 VA |
2,000 VA |
4,000 VA |
2,500 VA |
Note: Contact your OMRON representative for the ratings on fully sealed models.
Characteristics
| Item |
General-purpose
(High-capacity) Models |
General-purpose Models |
High-sensitivity Models |
| Number of poles |
1 pole |
2 poles |
1 pole |
| Contact resistance |
100 mΩ max. |
| Operate (set) time |
15 ms max. |
| Release (reset) time |
5 ms max. |
| Max. operating frequency |
Mechanical:18,000 operation/hr
Electrical:1,800 operation/hr at rated load |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
5,000 VAC, 1 min between coil and contacts
1,000 VAC, 1 min between contacts of same polarity |
5,000 VAC, 1 min between coil and contacts
2,500 VAC, 1 min between contacts of different polarity
1,000 VAC, 1 min between contacts of same polarity |
5,000 VAC, 1 min between coil and contacts 1,000 VAC, 1 min between contacts of same polarity |
| Impulse withstand voltage |
10 kV (1.2×50 μs) between coil and contact |
| Vibration resistance |
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
| Shock resistance |
Destruction: 1,000 m/s2 (approx. 100 G)
Malfunction: 100 m/s2 (approx. 10 G) |
| Endurance (Mechanical) |
20,000,000 operations (at 18,000 operations/hr) |
| Ambient temperature |
Operating: –40°C to 85°C (with no icing)
Storage: –40°C to 85°C (with no icing) |
| Ambient humidity |
5% to 85% |
| Weight |
Approx. 12 g |
Note: Values in the above table are the initial values.
Note: All units are in millimeters unless otherwise indicated.
G2RL-1A(-H), G2RL-1A4

*Indicates average dimensions.
|
Terminal Arrangement/Internal Connection (Bottom View)
 |
Mounting Holes (Bottom View)
 |
G2RL-1(-H), G2RL-14

*Indicates average dimensions.
|
Terminal Arrangement/Internal Connection (Bottom View)
 |
Mounting Holes (Bottom View)
 |
G2RL-1A-E, G2RL-1A4-E

*Indicates average dimensions.
|
Terminal Arrangement/Internal Connection
(Bottom View)
 |
Mounting Holes (Bottom View)
 |
G2RL-1-E, G2RL-14-E

*Indicates average dimensions.
|
Terminal Arrangement/Internal Connection
(Bottom View)
 |
Mounting Holes
(Bottom View)
 |
G2RL-2A, G2RL-2A4

*Indicates average dimensions.
|
Terminal Arrangement/Internal Connection
(Bottom View)
 |
Mounting Holes
(Bottom View)
 |
G2RL-2, G2RL-24

*Indicates average dimensions.
|
Terminal Arrangement/Internal Connection
(Bottom View)
 |
Mounting Holes
(Bottom View)
 |
|
Relays
Product Lineup
Support
Related Links


|