Power Relays
G2RG PCB Relay
Power Relay with 1.5-mm Contact Gap
- Clearance between contact terminals of the same
polarity: 1.5 mm min.
- Meets the requirements of European UPS standards.
Note:UPS: Uninterruptible power systems.
- Conforms to VDE0435 (VDE approval: C250 insulation grade), UL508, CSA22.2.
- Meets VDE0700 requirements for household products according to VDE0110.
- Cadmium-free contacts ensuring environmentfriendly use.
- Tracking resistance: CTI > 250 V.
|
|
| Contact form |
Rated coil voltage |
Model number |
| DPST-NO |
12 VDC
24 VDC |
G2RG-2A4 |
Coil Ratings
| Rated voltage |
Rated current |
Coil resistance |
Must-operate
voltage |
Must-release
voltage |
Maximum
allowable
voltage |
Power
consumption |
| 12 VDC |
66.6 mA |
180 Ω |
80% max. |
10% min. |
140%
(at 23ºC) |
Approx. 800 mW |
| 24 VDC |
33.3 mA |
720 Ω |
| Note:1. |
The rated current and coil resistance are for a coil temperature of 23ºC and have a tolerance of ±10%. |
| 2. |
The operating characteristics given in the above table are for a coil temperature of 23ºC. |
| 3. |
The maximum allowable voltage is the maximum possible value of the voltage that can be applied to the relay coil. |
Contact Ratings
| Load |
Resistive load |
| Contact mechanism |
Single |
| Contact material |
Ag alloy |
| Rated load |
250 VAC, 8 A |
| Rated carry current |
8A |
| Maximum switching voltage |
380 VAC, 125 VDC |
| Maximum switching current |
8 A |
Failure rate (P level, reference value)
(See note.) |
5 VDC, 10mA |
Note:This value is for a switching frequency of 120 operations/min.
Characteristics
Contact resistance
(See note 1.) |
100 mΩ max. |
| Operate time |
15 ms max. |
| Release time |
5 ms max. |
| Maximum switching frequency |
Mechanical |
18,000 operations/hr |
| Electrical |
1,800 operations/hr (under rated load) |
Insulation resistance
(See note 2.) |
1,000MΩ min. (at 500 VDC) |
| Dielectric strength |
5,000 VAC, 50/60 Hz for 1 min between coil and contacts
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of the same polarity |
| Impulse withstand voltage |
10 kV (1.2 × 50 μs) |
| Vibration resistance |
Destruction |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Malfunction |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Shock resistance |
Destruction |
1,000 m/s2 |
| Malfunction |
200m/s2 when energized |
| Endurance |
Mechanical |
1,000,000 operations min. (at 18,000 operations/hr) |
| Electrical |
10,000 operations min. (at 1,800 operations/hr under rated load) |
| Ambient operating temperature |
-40 to 70 ºC (with no icing or condensation) |
| Ambient operating humidity |
55% to 85% |
| Weight |
Approx. 17.2 g |
| Note:1. |
The above values are initial values (at an ambient temperature of 23 ºC). |
| 2. |
Measurement conditions: 5 VDC, 1 A, voltage-drop method. |
| 3. |
Measurement conditions: Measured with a 500-VDC megohmmeter at the same places as the dielectric strength. |
G2RG-2A4

*Figures in parentheses indicate average values. |
| |
PCB Mounting Holes(BOTTOM VIEW)
 |
Terminal Arrangement /
Internal Connections
(BOTTOM VIEW)
 (The coil has no polarity.) |
|
|