Power Relays
G2R-1 PCB Relay
A Power Relay for a Variety of Purposes with Various Models
- Conforms to VDE0435 (VDE approval: C250 insulation grade), UL508, CSA22.2, SEV, SEMKO.
- Meets VDE0700 requirements for household products according to VDE0110.
- Clearance and creepage distance: 8 mm / 8 m.
- Models with CTI250 material available.
- High-sensitivity (360 mW) and high-capacity (16 A) types available.
- Double-winding latching type available.
- Plug-in with test button and quick-connect terminals available.
- Highly functional socket available.
|
|
| Classification |
Enclosure ratings |
Coil ratings |
Contact form |
| SPST-NO |
SPDT |
| PCB terminal |
General-purpose |
Flux protection |
AC/DC |
G2R-1A |
G2R-1 |
| Fully sealed |
G2R-1A4 |
G2R-14 |
| Bifurcated contact |
Flux protection |
DC |
G2R-1AZ |
G2R-1Z |
| Fully sealed |
G2R-1AZ4 |
G2R-1Z4 |
| High-sensitivity |
Flux protection |
DC |
G2R-1A-H |
G2R-1-H |
| Double-winding latching |
Flux protection |
G2RK-1A |
G2RK-1 |
| Plug-in terminal |
General-purpose |
Unsealed |
AC/DC |
--- |
G2R-1-S |
| LED indicator |
--- |
G2R-1-SN |
| LED indicator with test button |
--- |
G2R-1-SNI |
| Diode |
DC |
--- |
G2R-1-SD |
| LED indicator and diode |
--- |
G2R-1-SND |
| LED indicator and diode with test button |
--- |
G2R-1-SNDI |
| Plug-in terminal (Bifurcated crossbar contact) |
General-purpose |
AC/DC |
G2R-1A3-S |
G2R-13-S |
| LED indicator |
G2R-1A3-SN |
G2R-13-SN |
| LED indicator and diode |
DC |
G2R-1A3-SND |
G2R-13-SND |
| Note: |
1. |
When ordering, add the rated coil voltage to the model number.
|
| |
. |
Example: G2R-1A |
 |
|
2. |
OMRON has also prepared the above relays with AgSnIn contacts, which are more tolerant of large inrush currents and physical movement compared with relays with standard contacts. When ordering, add "-ASI" to the model number.
Example: G2R-1A-ASI |
|
3. |
Standard, NO contact type relays are TV-3 class products in accordance with the TV standards of the UL/CSA. Models with AgSnIn contacts are TV-5 class products.
Example: G2R-1A-ASI
When ordering a TV-8 class model, insert "-TV8" into the model number as follows:
Example: G2R-1A-TV8-ASI |
|
4. |
Models with CTI250 material are also available.
Contact your OMRON representative for more details. |
Accessories (Order Separately) Connecting Sockets
| Number of poles |
Applicable Relay model |
Track / surface-mounting Socket |
Back-mounting Socket |
| Terminals |
Model |
| 1 pole |
G2R-1-S(N)(D)(ND)(NI)(NDI)G2R-13-
S (G2R-1A3-S)
| P2RF-05-E
P2RF-05 |
PCB terminals |
P2R-05P, P2R-057P |
| Solder terminals |
P2R-05A |
| Note: See Dimensions for details on socket size. |
Mounting Track
| Applicable socket |
Description |
Model |
| Track connecting socket |
Mounting track |
50 cm ( ) x 7.3 mm (t): PFP-50N
1 m ( ) x 7.3 mm (t): PFP-100N
1 m ( ) x 16 mm (t): PFP-100N2 |
| End plate |
PFP-M |
| Spacer |
PFP-S |
| Back connecting socket |
Mounting plate |
P2R-P* |
| *Used to mount several P2R-05A and P2R-08A connecting sockets side by side. |
Coil Ratings
| Rated voltage |
12
VAC |
24
VAC |
100/
(110)
VAC |
120
VAC |
200/
(220)
VAC |
220
VAC |
230
VAC |
240
VAC |
| Rated current |
50 Hz |
93
mA |
46.5
mA |
11
mA |
9.3
mA |
5.5
(4.0)
mA |
5.1
mA |
4.7
(3.7)
mA |
4.7
mA |
| 60 Hz |
75
mA |
37.5
mA |
9/
(10.6)
mA |
7.5
mA |
4.5
(5.3)
mA |
4.1
mA |
3.8
(3.1)
mA |
3.8
mA |
| Coil resistance |
65
Ω |
260
Ω |
4,600
Ω |
6,500
Ω |
20,200
(25,000)
Ω |
25,000
Ω |
26,850
(30,000)
Ω |
30,000
Ω |
Coil inductance
(H) (ref. value) |
Armature OFF |
0.19 |
0.81 |
13.34 |
21 |
51.3 |
57.5 |
62 |
65.5 |
| Armature ON |
0.39 |
1.55 |
26.84 |
42 |
102 |
117 |
124 |
131 |
| Must operate voltage |
80% max. of rated voltage |
| Must release voltage |
30% min. of rated voltage |
| Max. voltage |
140% of rated voltage (at 23ºC) |
| Power consumption |
Approx. 0.9 VA at 60 Hz (approx. 0.7 VA at 60 Hz) |
| Note: |
1. |
Rated voltage of bifurcated crossbar contact type: 100/(110) VAC, 200/(220) VAC, 230 VAC (Approx. 0.7 VA at 60 Hz) |
|
2. |
Depending on the type of Relay, some Relays do not have coil specifications. Contact your OMRON representative for more details. |
| Rated voltage |
5
VDC |
6
VDC |
12
VDC |
24
VDC |
48
VDC |
100
VDC |
| Rated current (50/60 Hz) |
106
mA |
88.2
mA |
43.6
mA |
21.8
mA |
11.5
mA |
5.3
mA |
| Coil resistance |
47
Ω |
68
Ω |
275
Ω |
1,100
Ω |
4,170
Ω |
18,860
Ω |
Coil inductance
(H) (ref. value) |
Armature OFF |
0.20 |
0.28 |
1.15 |
4.27 |
13.86 |
67.2 |
| Armature ON |
0.39 |
0.55 |
2.29 |
8.55 |
27.71 |
93.2 |
| Must operate voltage |
70% max. of rated voltage |
| Must release voltage |
15% min. of rated voltage |
| Max. voltage |
170% of rated voltage (at 23ºC) |
| Power consumption |
Approx. 0.53 W |
| Note:Rated voltage of bifurcated crossbar contact type: 12 VDC, 24 VDC |
High-sensitivity Relays
| Rated voltage |
5
VDC |
6
VDC |
12
VDC |
24
VDC |
48
VDC |
Rated current (50/60 Hz)
(see note 1.) |
71.4
mA |
60
mA |
30
mA |
15
mA |
7.5
mA |
| Coil resistance (see note 1.) |
70
Ω |
100
Ω |
400
Ω |
1,600
Ω |
6,400
Ω |
Coil inductance
(H) (ref. value) |
Armature OFF |
0.37 |
0.53 |
2.14 |
7.80 |
31.20 |
| Armature ON |
0.75 |
1.07 |
4.27 |
15.60 |
62.40 |
| Must operate voltage |
70% max. of rated voltage |
| Must release voltage |
15% min. of rated voltage |
| Max. voltage |
170% of rated voltage (at 23ºC) |
| Power consumption |
Approx. 0.36 W |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of +15%/-20% (AC rated current)
or ±10% (DC coil resistance). |
|
2. |
LEDs are used for the built-in operation indicator. For models equipped with these indications, the VAC rated current must be increased by approximately 1 mA; the VDC rated current, by approximately 4 mA. |
|
3. |
Operating characteristics are measured at a coil temperature of 23ºC. |
Double-winding Latching Relays
| Rated voltage |
5
VDC |
6
VDC |
12
VDC |
24
VDC |
| Set coil |
Rated current
(see note 1.) |
167
mA |
138
mA |
70.6
mA |
34.6
mA |
Coil resistance
(see note 1.) |
30
Ω |
43.5
Ω |
170
Ω |
694
Ω |
Coil inductance
(H) (ref. value) |
Armature OFF |
0.073 |
0.104 |
0.42 |
1.74 |
| Armature ON |
0.146 |
0.208 |
0.83 |
3.43 |
| Reset coil |
Rated current |
119
mA |
100
mA |
50
mA |
25
mA |
| Coil resistance |
42
Ω |
60
Ω |
240
Ω |
960
Ω |
Coil inductance
(H) (ref. value) |
Armature OFF |
0.003 |
0.005 |
0.018 |
0.079 |
| Armature ON |
0.006 |
0.009 |
0.036 |
0.148 |
| Must set voltage |
70% max. of rated voltage |
| Must reset voltage |
70% max. of rated voltage |
| Max. voltage |
140% of rated voltage (at 23ºC) |
| Power consumption |
Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
|
2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
Contact Ratings
PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays
| Item |
General-purpose, quick-connect terminal |
| Number of poles |
1 pole |
| Load |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4;
L/R = 7 ms) |
| Rated load |
10 (1) A at 250 VAC;
10 (1) A at 30 VDC |
7.5 A at 250 VAC;
5 A at 30 VDC |
| Rated carry current |
10 (1) A |
| Max. switching voltage |
380 VAC, 125
VDC |
| Max. switching current |
10 (1) A |
| Max. switching power |
2,500 (250) VA,
300 (30) W |
1,875 VA,
150 W |
Failure rate
(reference value) |
100 mA at 5 VDC (1 mA at 5 VDC) |
| Note: |
1. |
P level: λ60 = 0.1 x 10-6/operation |
|
2. |
( ): Bifurcated crossbar contact type. |
PCB/Flux Protection Relays
| Item |
Bifurcated contacts |
High-sensitivity |
| Number of poles |
1 pole |
1 pole |
| Load |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4;
L/R = 7 ms) |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4;
L/R = 7 ms) |
| Rated load |
5 A at 250 VAC;
5 A at 30
VDC |
2 A at 250 VAC;
3 A at 30
VDC |
5 A at 250 VAC;
5 A at 30
VDC |
2 A at 250 VAC;
3 A at 30
VDC |
| Rated carry current |
5 A |
5 A |
| Max. switching voltage |
380 VAC, 125 VDC |
380 VAC, 125 VDC |
| Max. switching current |
5 A |
5 A |
| Max. switching power |
1,250 VA,
150 W |
500 VA,
90 W |
1,250 VA,
150 W |
500 VA,
90 W |
Failure rate
(reference value) |
1 mA at 5 VDC |
100 mA at 5 VDC |
| Note: P level: λ60 = 0.1 x 10-6/operation |
PCB/Fully sealed Relays
| Item |
General-purpose (single contact) |
Bifurcated contact |
| Number of poles |
1 pole |
1 pole |
| Load |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4;
L/R = 7 ms) |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4;
L/R = 7 ms) |
| Rated load |
8 A at 250 VAC;
8 A at 30
VDC |
6 A at 250 VAC;
4 A at 30
VDC |
5 A at 250 VAC;
5 A at 30
VDC |
2 A at 250 VAC;
3 A at 30
VDC |
| Rated carry current |
8 A |
5 A |
| Max. switching voltage |
380 VAC, 125 VDC |
380 VAC, 125 VDC |
| Max. switching current |
8 A |
5 A |
| Max. switching power |
2,000 VA,
240 W |
1,500 VA,
120 W |
1,250 VA,
150 W |
500 VA,
90 W |
Failure rate
(reference value) |
100 mA at 5 VDC |
1 mA at 5 VDC |
| Note: P level: λ60 = 0.1 x 10-6/operation |
Latching Relays
| Number of poles |
1 pole |
| Load |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4;
L/R = 7 ms) |
| Rated load |
5 A at 250 VAC;
5 A at 30
VDC |
3.5 A at 250 VAC;
2.5 A at 30
VDC |
| Rated carry current |
5 A |
| Max. switching voltage |
380 VAC, 125
VDC |
| Max. switching current |
5 A |
| Max. switching power |
1,250 VA, 150 W |
875 VA, 75 W |
Failure rate
(reference value) |
100 mA at 5
VDC |
| Note: P level: λ60 = 0.1 x 10-6/operation |
Characteristics
| Item |
1 pole |
| Contact resistance |
30 mΩ max. (high-capacity type: 100 mΩ max.) |
| Operate (set) time |
15 ms max. |
| Release (reset) time |
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) |
| Max. operating frequency |
| Mechanical: |
18,000 operations/hr |
| Electrical: |
1,800 operations/hr (under rated load) |
|
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Malfunction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
|
| Shock resistance |
| Destruction: |
1,000 m/s2 |
| Malfunction: |
200 m/s2 when energized; 100m/s2 when no energized |
|
| Endurance |
| Mechanical: |
AC coil: 10,000,000 operations min.; |
| DC coil: |
20,000,000 operations min. (at 18,000 operations/hr) |
| Electrical: |
100,000 operations min. (at 1,800 operations/hr under rated load) |
|
| Ambient temperature |
Operating: -40ºC to 70ºC (with no icing) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 17 g (plug-in terminal: approx. 20 g) |
Standard Relays
| Note: |
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted. |
Double-winding Latching Relays
| Item |
1 pole |
| Contact resistance |
30 mΩ max. |
| Set time |
20 ms max. |
| Reset time |
20 ms max. |
| Min. set/reset signal width |
30 ms max. |
| Max. operating frequency |
| Mechanical: |
18,000 operations/hr |
| Electrical: |
1,800 operations/hr (under rated load) |
|
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of same pole;
1,000 VAC, 50/60 Hz for 1 min between set and reset coil |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Malfunction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
|
| Shock resistance |
| Destruction: |
1,000 m/s2(approx. 100G) |
| Malfunction: |
Set: 500 m/s2(approx. 50G); 200m/s2 (approx. 20G) |
| Reset: |
100m/s2 (approx. 10G) |
|
| Endurance |
| Mechanical: |
10,000,000 operations min (at 18,000 operations/hr) |
| Electrical: |
100,000 operations min. (at 1,800 operations/hr under rated load) |
|
| Ambient temperature |
Operating: -40ºC to 70ºC (with no icing) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 17 g |
| Note: |
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted. |
| Note:1. |
All units are in millimeters unless otherwise indicated. |
| 2. |
Orientation marks are indicated as follows: |
Relays with PCB Terminals
SPDT Relays
G2R-1, G2R-1Z, G2R-1-H

|
Terminal Arrangement /
Internal Connections
(Bottom View)
 |
Mounting Holes
(Bottom View)
Tolerance: ±0.1

(No coil polarity) |
|
|
SPST-NO Relays
G2R-1A, G2R-1AZ, G2R-1A-H
|
Terminal Arrangement /
Internal Connections
(Bottom View)
 |
Mounting Holes
(Bottom View)
Tolerance: ±0.1

(No coil polarity) |
|
|
Relays with PCB Terminals
SPDT Relays
G2R-14, G2R-1Z4

|
Terminal Arrangement /
Internal Connections
(Bottom View)
 |
Mounting Holes
(Bottom View)
Tolerance: ±0.1
 |
|
SPST-NO Relays
G2R-1A4, G2R-1AZ4
 |
Terminal Arrangement /
Internal Connections
(Bottom View)
 |
Mounting Holes
(Bottom View)
Tolerance: ±0.1

(No coil polarity) |
|
|
Relays with Plug-in Terminals
SPDT Relays
G2R-1-S, G2R-1-SD, G2R-1-SN, G2R-1-SND, G2R-1-SNI, G2R-1-SNDI
G2R-13-S, G2R-13-SD, G2R-13-SN, G2R-13-SND

|
Terminal Arrangement / Internal Connections
(Bottom View)

(After confirming coil polarity, wire correctly.)
(Except G2R-1-S, G2R-13-S) |
|
Double-winding Latching Relays with PCB Terminals
SPDT Relays
G2RK-1

|
Terminal Arrangement /
Internal Connections
(Bottom View)

(After confirming coil polarity, wire correctly.) |
Mounting Holes
(Bottom View)
Tolerance: ±0.1

(After confirming coil polarity, wire correctly.) |
|
|
Double-winding Latching Relays with PCB Terminals.
SPST-NO Relays
G2RK-1A

|
Terminal Arrangement /
Internal Connections
(Bottom View)
 |
Mounting Holes
(Bottom View)
Tolerance: ±0.1

(After confirming coil polarity, wire correctly.) |
|
|
Relays with Quick-connect Terminals
SPDT Relays
G2R-1-T

|
Terminal Arrangement / Internal Connections
(Bottom View)

(No coil polarity) |
Mounting Holes(Bottom View)
Tolerance: ±0.1
 |
SPST-NO Relays
G2R-1A-T
 |
Terminal Arrangement / Internal Connections
(Bottom View)

(No coil polarity) |
Mounting Holes(Bottom View)

Note: Model number of quick-connect terminal is 187. |
|
Relays
Products Lineup
Relational Contents
Contact Us
|