G3VM-61G1 MOS FET Relays
New MOS FET Relay Designed for Switching Minute Signals and Analog Signals
  • Upgraded G3VM-S1 Series.
  • Continuous load current of 400 mA.
  • Dielectric strength of 1,500 Vrms between I/O.
G3VM-61G1
Note:The actual product is marked differently from the image shown here.
JPN
OrderingInformationRatings / CharacteristicsDimensions
Contact form Terminals Load voltage (peak value) Model Number per stick Number per tape
SPST-NO Surface-mounting terminals 60 VAC G3VM-61G1 100 ---
G3VM-61G1(TR) --- 2,500
OrderingInformationRatings / CharacteristicsDimensions
Absolute Maximum Ratings (Ta = 25ºC)
Item Symbol Rating Unit Measurement Conditions
Input LED forward current IF 50 mA
Repetitive peak LED forward current IFP 1 A 100µs pulses,
100 pps
LED forward current reduction rate Δ IF/ºC -0.5 mA/ºC Ta ≥ 25ºC
LED reverse voltage VR 5 V
Connection temperature Tj 125 ºC
Output Output dielectric strength VOFF 60 V
Continuous load current IO 400 mA
ON current reduction rate Δ ION/ºC -4.0 mA/ºC Ta ≥ 25ºC
Connection temperature Tj 125 ºC
Dielectric strength between input and output (See note 1.) VI-O 1,500 Vrms AC for 1 min
Operating temperature Ta -40 to + 85 ºC With no icing or condensation
Storage temperature Tstg -55 to + 125 ºC With no icing or condensation
Soldering temperature (10 s) --- 260 ºC 10 s
Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side.

Item Symbol Minimum Typical Maximum Unit Measurement Conditions
Input LED forward voltage VF 1.0 1.15 1.3 V IF=10 mA
Reverse current IR --- --- 10 µA VR= 5V
Capacity between terminals CT --- 30 --- pF V=0,
f=1MHz
Trigger LED forward current IFT --- 1.6 3 mA IO=400mA
Output Maximum resistance with output ON RON --- 1 2 Ω IF = 5mA
IO=400mA
Current leakage when the relay is open ILEAK --- --- 1.0 µA VOFF=60V
Capacity between I/O terminals CI-O --- 0.8 --- pF f=1 MHz,
Vs = 0V
Insulation resistance RI-O 1,000 --- --- VI-O=500VDC,
RoH ≤ 60%
Turn-ON time tON --- 0.8 2.0 ms IF=5 mA,
RL=200Ω
VDD=20V
(See note 2.)
Turn-OFF time tOFF --- 0.1 0.5 ms
Note : 2. Turn-ON and Turn-OFF Times
G3VM_61G1:Ratings/Characteristics1
OrderingInformationRatings / CharacteristicsDimensions
Note:
All units are in millimeters unless otherwise indicated.

G3VM-61G1
G3VM-61G1:Dimensions1
Weight: 0.1 g
Note:
The actual product is marked differently from the image shown here.

Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-61G1:Dimensions2
Terminal Arrangement/
Internal Connections

(Top View)
G3VM-61G1:Dimensions3