| Contact form | Terminals | Load voltage (peak value) (See note.) |
Model | Minimum packaging unit |
|---|---|---|---|---|
| Number per fape | ||||
| SPST-NO | Surface-mounting terminals | 20 V | G3VM-21LR11 | --- |
| G3VM-21LR11(TR) | 1,500 |
| Note : | 1. | Ask your OMRON representative for orders under 1,500 pcs. |
| 2. | Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to Common Precautions. | |
| 3. | The AC peak and DC value is given for the load voltage. |
| Item | Symbol | Rating | Unit | Measurement Conditions | |
|---|---|---|---|---|---|
| Input | LED forward current | IF | 50 | mA | |
| LED forward current reduction rate | Δ IF/ºC | -0.5 | mA/ºC | Ta ≥ 25ºC | |
| LED reverse voltage | VR | 5 | V | ||
| Connection temperature | Tj | 125 | ºC | ||
| Output | Load voltage (AC peak/DC) | VOFF | 20 | V | |
| Continuous load current (AC peak/DC) | IO | 900 | ma | ||
| ON current reduction rate | Δ ION/ºC | -12 | mA/ºC | Ta ≥ 50ºC | |
| Connection temperature | Tj | 125 | ºC | ||
| Dielectric strength between input and output (See note 1.) |
VI-O | 1,500 | Vrms | AC for 1 min | |
| Ambient operating temperature | Ta | -20 to + 85 | ºC | With no icing or condensation | |
| Storage temperature | Tstg | -40 to + 125 | ºC | With no icing or condensation | |
| Soldering temperature | --- | 260 | ºC | 10 s | |
| Note: 1. | The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. |
| Item | Symbol | Minimum | Typical | Maximum | Unit | Measurement Conditions | |
|---|---|---|---|---|---|---|---|
| Input | LED forward voltage | VF | 1.0 | 1.15 | 1.3 | V | IF=10 mA |
| Reverse current | IR | --- | --- | 10 | µA | VR= 5V | |
| Capacity between terminals | CT | --- | 15 | --- | pF | V=0, f=1MHz |
|
| Trigger LED forward current | IFT | --- | --- | 3 | mA | IO=100mA | |
| Output | Maximum resistance with output ON | RON | --- | 0.18 | 0.22 | Ω | IF = 5mA IO=900mA , t < IS |
Current leakage when the relay is open | ILEAK | --- | --- | 1 | nA | VCFF = 20V |
| Capacity between terminals | COFF | --- | 40 | --- | pF | V = 0 f = 100MHz , t < 1S |
|
| Capacity between I/O terminals | CI-O | --- | 0.3 | --- | pF | f=1 MHz, Vs = 0V |
|
| Insulation resistance between I/O termainals | RI-O | 1,000 | --- | --- | MΩ | VI-O=500 VDC, RoH ≤ 60% |
|
| Turn-ON time | tON | --- | 0.3 | 2 | ms | IF=5 mA, RL=200Ω VDD=10V (See note 2.) |
|
| Turn-OFF time | tOFF | --- | 0.2 | 1 | ms | ||
| Note: 2. | Turn-ON and Turn-OFF
Times![]() |
![]()
|
|||||||||
| Terminal Arrangement/Internal Connections (Top View) G3VM-21LR11 ![]() |