MOS FET Relays
G3VM-101LR MOS FET Relays
World's Smallest SSOP Package MOS FET Relays with High Load Voltage of 100 V.
- Leakage current of 200 pA max. when output relay is open.
- Information correct as of May 2007, according to data obtained by OMRON.

The actual product is marked differently from the image
shown here. |
|
|
|
|
|
|
Updated June 1, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Contact form |
Terminals |
Load voltage (peak value) |
Model |
| SPST-NO |
Surface-mounting terminals |
100 VAC |
G3VM-101LR |
| G3VM-101LR (TR) |
Absolute Maximum Ratings (Ta = 25ºC)
| Item |
Symbol |
Rating |
Unit |
Measurement Conditions |
| Input |
LED forward current |
IF |
50 |
mA |
|
| LED forward current reduction rate |
ΔIF/ºC |
-0.5 |
mA/ºC |
Ta≥25ºC |
| LED reverse voltage |
VR |
5 |
V |
|
| Connection temperature |
Tj |
125 |
ºC |
|
| Output |
Output dielectric strength |
VOFF |
100 |
V |
|
| Continuous load current |
IO |
80 |
mA |
|
| ON current reduction rate |
ΔION/ºC |
-0.8 |
mA/ºC |
Ta≥25ºC |
| Connection temperature |
Tj |
125 |
ºC |
|
Dielectric strength between input and output (See note 1.) |
VI-O |
1,500 |
Vrms |
AC for 1 min |
| Ambient operating temperature |
Ta |
-20 to +85 |
ºC |
With no icing or condensation |
| Storage temperature |
Tstg |
-40 to +125 |
ºC |
With no icing or condensation |
| Soldering temperature |
--- |
260 |
ºC |
10 s |
| Note: |
1. The dielectric strength between
the input and output was checked by applying voltage between
all pins as a group on the LED side and all pins as a group on the light-receiving side. |
Electrical Characteristics (Ta = 25ºC)
| Item |
Symbol |
Minimum |
Typical |
Maximum |
Unit |
Measurement conditions |
| Input |
LED forward voltage |
VF |
1.0 |
1.15 |
1.3 |
V |
IF=10mA |
| Reverse current |
IR |
--- |
--- |
10 |
µA |
VR=5V |
| Capacity between terminals |
CT |
--- |
15 |
--- |
pF |
V=0,f=1MHz |
| Trigger LED forward current |
IFT |
--- |
1 |
5 |
mA |
IO=80mA |
| Output |
Maximum resistance with output ON |
RON |
--- |
8 |
14 |
Ω |
IF=10mA, IO=80mA, t=10ms |
| Current leakage when the relay is open |
ILEAK |
--- |
--- |
200 |
pA |
VOFF=80V |
| Capacity between terminals |
COFF |
--- |
6 |
8 |
pF |
V=0,f=100MHz, t<1s |
| Capacity between I/O terminals |
CI-O |
--- |
0.6 |
--- |
pF |
f=1MHz,Vs=0V |
| Insulation resistance between I/O terminals |
RI-O |
1,000 |
--- |
--- |
MΩ |
VI-O=500VDC, RoH≤60% |
| Turn-ON time |
tON |
--- |
0.1 |
0.3 |
ms |
IF=5mA,RL=200Ω,
VDD=20V (See note 2.) |
| Turn-OFF time |
tOFF |
--- |
0.1 |
0.3 |
ms |
Note: 2. Turn-ON and Turn-OFF Times
Note: All units are in millimeters unless otherwise indicated.
G3VM-101LR  Note: The actual product is marked differently
from the image shown here. Note: A tolerance of ±0.1 mm applies to
all dimensions unless otherwise
specified. |
Actual Mounting Pad Dimensions (Recommended
Value, Top View)  |
Terminal Arrangement/Internal Connections (Top View)  |
|
Relays
Product Lineup
Support