High-Frequency Relays
G6Z Surface-mounting High-frequency Relay
Surface-mounting, 2.6-GHz-Band, Miniature, SPDT, High-frequency Relay
- Superior high-frequency characteristics, such as an isolation of 30 dB min., insertion loss of 0.5 dB max., and V.SWR of 1.5 max. at 2.6 GHz.
- Surface-mounting terminals and superior high frequency characteristics combined using semi triplate strip transmission lines.
- Miniature dimensions of 20 × 8.6× 8.9 mm (L×W×H).
- Choose from a lineup that includes single-winding latching models (200 mW), double-winding latching models (360 mW), and models with a reverse contact arrangement.
- Series includes models with an E-shape terminal structure (same as existing models), and models with a Y-shape terminal structure, allowing greater freedom with PCB design.
- Models with 75Ωimpedance and models with 50Ω impedance are available.
|
|
Standard Models with PCB Terminals
Classifi- cation |
Struc- ture |
Contact form |
Terminal arrange- ment |
Characteristic impedance |
Rated coil voltage |
Model |
| Single side stable |
Plastic sealed |
SPDT |
E-shape |
75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1PE |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1PE-A |
| Y-shape |
75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1P |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1P-A |
| Single winding latching |
E-shape |
75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1PE |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1PE-A |
| Y-shape |
75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1P |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1P-A |
| Double winding latching |
E-shape |
75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1PE |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1PE-A |
| Y-shape |
75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1P |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1P-A |
Standard Models with Surface-mounting Terminals
Classifi- cation |
Struc- ture |
Contact form |
Terminal arrange- ment |
Characteristic impedance |
Rated coil voltage |
Model |
| Single side stable
| Plastic sealed
| SPDT
| E-shape
| 75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1FE |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1FE-A |
| Y-shape
| 75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1F |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6Z-1F-A |
| Single winding latching
| E-shape
| 75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1FE |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1FE-A |
| Y-shape
| 75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1F |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZU-1F-A |
| Double winding latching
| E-shape
| 75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1FE |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1FE-A |
| Y-shape
| 75 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1F |
| 50 Ω |
3, 4.5, 5, 9, 12, and 24 VDC |
G6ZK-1F-A |
| Note: |
When ordering tape packing (surface-mounting models), add "-TR" to the model number. "-TR" does not appear on the Relay itself. |
| Stick Packing and Tape Packing |
Stick Packing Relays in stick packing are arranged so that the orientation markof each Relay in on the left side. Be sure not to make mistakes in Relay orientation when mountingthe Relay to the PCB.  Stick length: 530 mm (stopper not included) No. of Relays per stick: 25 |
Tape Packing (Surface-mounting Terminal Models) When ordering Relays in tape packing, add the prefix "-TR" to themodel number, otherwise the Relays in stick packing will be pro-vided. Relays per Reel: 300 |
1. Direction of Relay Insertion
 |
2. Reel Dimensions
 |
3. Carrier Tape Dimensions
 Note:The radius of the unmarked corner is 0.3 mm. |
Coil Ratings Single-side Stable Models G6Z-1P(E), G6Z-1F(E)
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
9 VDC |
12 VDC |
24 VDC |
| Rated current |
66.7 mA |
44.4 mA |
40.0 mA |
22.2 mA |
16.7 mA |
8.3 mA |
| Coil resistance |
45 Ω |
101 Ω |
125 Ω |
405 Ω |
720 Ω |
2,880 Ω |
| Must operate voltage |
75% max. of rated voltage |
| Must release voltage |
valign="top"10% min. of rated voltage |
| Maximum voltage |
150% of rated voltage |
| Power consumption |
Approx. 200 mW |
Single-winding Latching Models G6ZU-1P(E), G6ZU-1F(E)
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
9 VDC |
12 VDC |
24 VDC |
| Rated current |
66.7 mA |
44.4 mA |
40.0 mA |
22.2 mA |
16.7 mA |
8.3 mA |
| Coil resistance |
45 Ω |
101 Ω |
125 Ω |
405 Ω |
720 Ω |
2,880 Ω |
| Must operate voltage |
75% max. of rated voltage |
| Must release voltage |
75% max. of rated voltage |
| Maximum voltage |
150% of rated voltage |
| Power consumption |
Approx. 200 mW |
Double-winding Latching Models G6ZK-1P(E), G6ZK-1F(E)
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
9 VDC |
12 VDC |
24 VDC |
| Rated current |
120 mA |
80 mA |
72 mA |
40 mA |
30 mA |
15 mA |
| Coil resistance |
25 Ω |
56 Ω |
69 Ω |
225 Ω |
400 Ω |
1,600 Ω |
| Must operate voltage |
75% max. of rated voltage |
| Must release voltage |
75% max. of rated voltage |
| Maximum voltage |
150% of rated voltage |
| Power consumption |
Approx. 360 mW |
| Note: 1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| 2. |
The Operating characteristics are measured at a coil temperature of 23ºC. |
| 3. |
The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. |
Contact Ratings
| Load |
Resistive load |
| Rated load |
10 mA at 30 VAC; 10 mA at 30 VDC; 10 W at 900 MHz (See note.) |
| Rated carry current |
0.5A |
| Max. switching voltage |
30 VAC, 30 VDC |
| Max. switching current |
0.5A |
Note:This value is for an impedance of 50 Ωor 75 Ω with a V.SWR of 1.2 max. High-frequency Characteristics
Frequency  |
| Item |
|
900 MHz |
2.6 GHz |
| TH |
SMD |
TH |
SMD |
| E-shape |
Y-shape |
E-shape |
Y-shape |
E-shape |
Y-shape |
E-shape |
Y-shape |
| Isolation |
75 Ω |
65 dB min. |
60 dB min. |
35 dB min. |
45 dB min. |
30 dB min. |
40 dB min. |
| 50 Ω |
60 dB min. |
| Insertion loss (not including substrate loss) |
75 Ω |
0.2 dB max. |
0.5 dB max. |
| 50 Ω |
0.1 dB max. |
0.3 dB max. |
| V.SWR |
75 Ω |
1.2 max. |
1.5 max. |
| 50 Ω |
1.1 max. |
1.3 max. |
| Return loss |
75 Ω |
20.8 dB max. |
14.0 dB max. |
| 50 Ω |
26.4 dB max. |
17.7 dB max. |
| Maximum carry power |
10 W (See note 2.) |
| Maximum switching power |
10 W (See note 2.) |
| Note: 1. |
The above values are initial values. |
| 2. |
These values are for an impedance of 50 Ωor 75 Ωwith a V.SWR of 1.2 max. |
Characteristics
| Item |
Single-side stable models |
Single-winding latching models |
Double-winding latching models |
G6Z-1P(E), G6Z-1F(E) |
G6ZU-1P(E), G6ZU-1F(E) |
G6ZK-1P(E), G6ZK-1F(E) |
Contact resistance (See note 2.) |
100 mΩ max. |
Operating (set) time (See note 3.) |
10 ms max. (approx. 3.5 ms) |
10 ms max. (approx. 2.5 ms) |
Release (reset) time (See note 3.) |
10 ms max. (approx. 2.5 ms) |
| Minimum set/reset pulse time |
--- |
12 ms |
Insulation resistance (See note 4.) |
100 M Ω min. (at 500 VDC) |
| Dielectric strength |
Coil and contacts |
1,000 VAC, 50/60 Hz for 1 min |
| Coil and ground, contacts and ground |
500 VAC, 50/60 Hz for 1 min |
| Contacts of same polarity |
500 VAC, 50/60 Hz for 1 min |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Malfunction: |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
|
| Shock resistance |
Destruction: 1,000 m/s2 Malfunction: 500 m/s2 |
| Endurance |
| Mechanical: |
1,000,000 operations min. (at 36,000 operations/hour) |
| Electrical: |
300,000 operations min. (30 VAC, 10 mA/30 VDC, 10 mA), 100,000 operations min. (900 MHz, 10 W) at a switching frequency of 1,800 operations/hour |
|
| Ambient temperature |
Operating: -40ºC to 70ºC (with no icing or condensation) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 2.8 g |
| Note: 1. |
The above values are initial values. |
| 2. |
The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. |
| 3. |
Values in parentheses are actual values. |
| 4. |
The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. |
Note: |
All units are in millimeters unless otherwise
indicated. |
Models with
PCB Terminals
G6Z-1PE G6ZU-1PE G6Z-1PE-R  |
Mounting Dimensions (Bottom View) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Bottom View)  |
Note:Each value has a tolerance of ± 0.3 mm.
|
|
G6Z-1PE-A G6ZU-1PE-A  |
Mounting Dimensions (Bottom View) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Bottom View)  |
Note:Each value has a tolerance of ± 0.3 mm.
|
|
G6Z-1P G6ZU-1P  |
Mounting Dimensions (Bottom View) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Bottom View)  |
Note:Each value has a tolerance of ± 0.3 mm.
|
|
G6Z-1P-A G6ZU-1P-A  |
Mounting Dimensions (Bottom View) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Bottom View)  |
Note:Each value has a tolerance of ± 0.3 mm. |
|
G6ZK-1PE  |
Mounting Dimensions (Bottom View) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Bottom View)  |
Note:Each value has a tolerance of ± 0.3 mm. |
|
G6ZK-1PE-A  |
Mounting Dimensions (Bottom View) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Bottom View)  |
Note:Each value has a tolerance of ± 0.3 mm. |
|
G6ZK-1P  |
Mounting Dimensions (Bottom View) Tolerance:±0.1mmmm  |
Terminal Arrangement/ Internal
Connections (Bottom View)  |
Note:Each value has a tolerance of ± 0.3 mm. |
|
G6ZK-1P-A  |
Mounting Dimensions (Bottom VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Bottom VIEW)  |
Note:Each value has a tolerance of ± 0.3 mm. |
|
Models with Surgace-mounting Terminals |
G6Z-1FE G6ZU-1FE  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
G6Z-1FE-A G6ZU-1FE-A  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
G6Z-1F G6ZU-1F  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
G6Z-1F-A G6ZU-1F-A  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
G6ZK-1FE  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
G6ZK-1FE-A  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
G6ZK-1F  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
G6ZK-1F-A  |
Mounting Dimensions (Top VIEW) Tolerance:±0.1mm  |
Terminal Arrangement/ Internal
Connections (Top VIEW)  |
Note 1: |
Each value has a tolerance of ± 0.3 mm. |
2: |
The coplanarity of the terminals is 0.1 mm
max |
|
|
Relays
Products Lineup
Relational Contents
Contact Us
Relational Contents
|