G6S PCB Relay

Surface Mounting DPDT Relay

  • Long terminals ideal for soldering and mounting reliability.
  • Space-saving inside-L terminal.
  • High dielectric strength between coil and contacts (2,000 VAC), and between contacts of different polarity (1,500 VAC).
  • High impulse withstand voltages between coil and contacts, and between contacts of different polarity (2,500 V, 2 × 10 µs: Bellcore requirements).
  • Low power consumption (140 mW).
  • Bifurcated crossbar contact (Au-clad) and fully sealed construction for high reliability.
  • Applicable to IRS.
  • High sealability after IRS.
  • Ultra-miniature at 15×7.5×9.4 mm (L× W×H).
  • Through-hole terminal is available.
  • EN60950/EN41003 Supplementary Insulation-certified type is available.
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Classification Single-side stable Single-winding latching Double-winding latching Single-side stable
EN60950/EN41003
DPDT Fully sealed Through-hole terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y
Surface mounting terminal Inside-L G6S-2G G6SU-2G G6SK-2G G6S-2G-Y
Outside-L G6S-2F G6SU-2F G6SK-2F G6S-2F-Y
Note: 1. When ordering, add the rated coil voltage to the model number.
    Example: G6S-2F
  2. When ordering tape packing, add "-TR" to the model number.
    Example: G6S-2F
    Note that since "-TR" is not part of the relay model number, it is not marked on the relay case.

Tape Packing
When ordering, add "-TR" before the rated coil voltage for tape packing.
Tape Type : TE2416R(Refer to EIAJ)
Reel type : R24E(Refer to EIAJ)
Relays per Reel : 400
G6S:Ordering Information2

G6S:Ordering Information1

G6S:Ordering Information3

G6S:Ordering Information4
OrderingInformationRatings / CharacteristicsDimensions
Coil Ratings
Single-side Stable Type (G6S-2, G6S-2F, G6S-2G)
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 46.7 mA 31.0 mA 28.1 mA 11.7 mA 8.3 mA
Coil resistance 64.3 Ω 145 Ω 178 Ω 1,028 Ω 2,880 Ω
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 200% of rated voltage at 23ºC,130% at 85ºC 170% of rated voltage at 23ºC,130% at 85ºC
Power consumption Approx. 140 mW Approx. 200 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
  2. Operating characteristics are measured at a coil temperature of 23ºC.

Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G)
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 33.3 mA 22.2 mA 20 mA 8.3 mA 6.3 mA
Coil resistance 90 Ω 203 Ω 250 Ω 1,440 Ω 3,840 Ω
Coil inductance(H) (ref. value) Armature OFF 0.08 0.27 0.36 2.12 5.80
Armature ON 0.04 0.14 0.18 1.14 3.79
Must set voltage 75% max. of rated voltage
Must reset voltage 75% max. of rated voltage
Max. voltage 180% of rated voltage at 23ºC 140% at 85ºC
Power consumption Approx. 100 mW Approx. 150 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
  2. Operating characteristics are measured at a coil temperature of 23ºC.


Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G)
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 66.6 mA 44.4 mA 40 mA 16.7 mA 12.5 mA
Coil resistance 45 Ω 101 Ω 125 Ω 720 Ω 1,920 Ω
Coil inductance(H) (ref. value) Set Armature OFF 0.05 0.12 0.14 0.60 1.98
Armature ON 0.03 0.074 0.088 0.41 1.23
Reset Armature OFF 0.03 0.082 0.098 0.46 1.34
Armature ON 0.06 0.14 0.16 0.54 2.23
Must set voltage 75% max. of rated voltage
Must reset voltage 75% max. of rated voltage
Max. voltage 170% of rated voltage at 23ºC, 130% at 85ºC 140% of rated voltage at 23ºC, 110% at 70ºC
Power consumption Approx. 200 mW Approx. 300 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
  2. Operating characteristics are measured at a coil temperature of 23ºC.


Single-side Stable EN60950/EN41003 Approved Type
(G6S-2-Y, G6S-2F-Y, G6S-2G-Y)

Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 40 mA 16.7 mA 9.6 mA
Coil resistance 125 Ω 720 Ω 2,504 Ω
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 170% of rated voltage at 23ºC, 130% at 85ºC 170% of rated voltage at 23ºC, 110% at 70ºC
Power consumption Approx. 200 mW Approx. 230 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
  2. Operating characteristics are measured at a coil temperature of 23ºC.


Contact Ratings
Load Resistive load (cosφ = 1)
Rated load 0.5 A at 125 VAC; 2 A at 30 VDC
Contact material Ag (Au-clad)
Rated carry current 2A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 2A
Max. switching capacity 62.5 VA, 60 W
Failure rate (reference value) 10 µA at 10 mVDC
Note: P level: λ60 = 0.1 × 10-6/operation


Characteristics
Contact resistance 75 mΩ max.
Operating (set) time 4 ms max. (mean value: approx. 2.5 ms; latching type: approx. 2 ms)
Release (reset) time 4 ms max. (mean value: approx. 1.5 ms; latching type: approx. 2 ms)
Bounce time Operate: Approx. 0.5 ms
Release: Approx. 0.5 ms
Set/Reset: Approx. 0.5 ms
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching)
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
500 VAC, 50/60 Hz for 1 min between set and reset coil (double-winding latching)
Impulse withstand voltage 2,500 V (2 ×10 µs) between coil and contacts
1,500 V (10×160 µs) between coil and contacts (double-winding latching)
2,500 V (2×10 µs) between contacts of different polarity
1,500 V (10×160 µs) between contacts of same polarity (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2(approx. 100G)
Malfunction: 750 m/s2(approx. 75G)
Endurance
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr)
100,000 operations min. (0.5 A at 125 VAC, resistive load)
Ambient temperature Operating: -40ºC to 85ºC (with no icing)
-40ºC to 70ºC (double-winding latching, 24 VDC)
Ambient humidity Operating: 5% to 85%
Weight Approx. 2 g
OrderingInformationRatings / CharacteristicsDimensions
Note: All units are in millimeters unless otherwise indicated.


Single-side Stable
G6S-2, G6S-2-Y
Tolerance of ±0.3

G6S:Dimensions1
Footprint
(Bottom VIEW)
Tolerance:±0.1

G6S:Dimensions2
Terminal Arrangement/
Internal Connections

(Bottom VIEW)
G6S:Dimensions3
G6S-2F, G6S-2F-Y
Tolerance of ±0.3

G6S:Dimensions4
Footprint
(Top VIEW)
Tolerance:±0.1

G6S:Dimensions5
Terminal Arrangement/
Internal Connections

(Top VIEW)
G6S:Dimensions6
G6S-2G , G6S-2G-Y
Tolerance of ±0.3

G6S:Dimensions7
Footprint
(Top VIEW)
Tolerance:±0.1

G6S:Dimensions8
Terminal Arrangement/
Internal Connections

(Top VIEW)
G6S:Dimensions9
Single-winding Latching
G6SU-2
Tolerance of ±0.3

G6S:Dimensions10
Footprint
(Bottom VIEW)
Tolerance:±0.1

G6S:Dimensions11
Terminal Arrangement/
Internal Connections

(Bottom VIEW)
G6S:Dimensions12
G6SU-2F
Tolerance of ±0.3

G6S:Dimensions13
Footprint
(Top VIEW)
Tolerance:±0.1

G6S:Dimensions14
Terminal Arrangement/
Internal Connections

(Top VIEW)
G6S:Dimensions15
G6SU-2G
Tolerance of ±0.3

G6S:Dimensions16
Footprint
(Top VIEW)
Tolerance:±0.1

G6S:Dimensions17
Terminal Arrangement/
Internal Connections

(Top VIEW)
G6S:Dimensions18
Double-winding Latching
G6SK-2
Tolerance of ±0.3

G6S:Dimensions19
Footprint
(Bottom VIEW)
Tolerance:±0.1

G6S:Dimensions20
Terminal Arrangement/
Internal Connections

(Bottom VIEW)
G6S:Dimensions22
G6SK-2F
Tolerance of ±0.3

G6S:Dimensions22
Footprint
(TOP VIEW)
Tolerance:±0.1
G6S:Dimensions23
Terminal Arrangement/
Internal Connections

(TOP VIEW)
G6S:Dimensions24
G6SK-2G
Tolerance of ±0.3

G6S:Dimensions25
Footprint
(TOP VIEW)
Tolerance:±0.1

G6S:Dimensions26
Terminal Arrangement/
Internal Connections

(TOP VIEW)
G6S:Dimensions27
Related Links
Technology
Application Guide