Signal Relays
G6S PCB Relay
Surface Mounting DPDT Relay
- Long terminals ideal for soldering and mounting reliability.
- Space-saving inside-L terminal.
- High dielectric strength between coil and contacts (2,000 VAC), and between contacts of different polarity (1,500 VAC).
- High impulse withstand voltages between coil and contacts, and between contacts of different polarity (2,500 V, 2 × 10 µs: Bellcore requirements).
- Low power consumption (140 mW).
- Bifurcated crossbar contact (Au-clad) and fully sealed construction for high reliability.
- Applicable to IRS.
- High sealability after IRS.
- Ultra-miniature at 15×7.5×9.4 mm (L× W×H).
- Through-hole terminal is available.
- EN60950/EN41003 Supplementary Insulation-certified type is available.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
Single-side stable |
Single-winding latching |
Double-winding latching |
Single-side stable EN60950/EN41003 |
| DPDT |
Fully sealed |
Through-hole terminal
| G6S-2 |
G6SU-2 |
G6SK-2 |
G6S-2-Y |
| Surface mounting terminal |
Inside-L |
G6S-2G |
G6SU-2G |
G6SK-2G |
G6S-2G-Y |
| Outside-L |
G6S-2F |
G6SU-2F |
G6SK-2F |
G6S-2F-Y |
| Note: |
1. |
When ordering, add the rated coil voltage to the model number. |
| |
|
Example: G6S-2F |
 |
| |
2. |
When ordering tape packing, add "-TR" to the model number. |
| |
|
Example: G6S-2F |
 |
| |
|
Note that since "-TR" is not part of the relay model number, it is not marked on the relay case. |
| Tape Packing |
| When ordering, add "-TR" before the rated coil voltage for tape packing.
|
| Tape Type |
: TE2416R(Refer to EIAJ) |
| Reel type |
: R24E(Refer to EIAJ) |
| Relays per Reel |
: 400 |
|
 |
 |

 |
Coil Ratings
Single-side Stable Type (G6S-2, G6S-2F, G6S-2G)
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
46.7 mA |
31.0 mA |
28.1 mA |
11.7 mA |
8.3 mA |
| Coil resistance |
64.3 Ω |
145 Ω |
178 Ω |
1,028 Ω |
2,880 Ω |
| Must operate voltage |
75% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
200% of rated voltage at 23ºC,130% at 85ºC |
170% of rated voltage at 23ºC,130% at 85ºC |
| Power consumption |
Approx. 140 mW |
Approx. 200 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
|
Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G)
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
33.3 mA |
22.2 mA |
20 mA |
8.3 mA |
6.3 mA |
| Coil resistance |
90 Ω |
203 Ω |
250 Ω |
1,440 Ω |
3,840 Ω |
| Coil inductance(H) (ref. value) |
Armature OFF |
0.08 |
0.27 |
0.36 |
2.12 |
5.80 |
| Armature ON |
0.04 |
0.14 |
0.18 |
1.14 |
3.79 |
| Must set voltage |
75% max. of rated voltage |
| Must reset voltage |
75% max. of rated voltage |
| Max. voltage |
180% of rated voltage at 23ºC 140% at 85ºC |
| Power consumption |
Approx. 100 mW |
Approx. 150 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
|
Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G)
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
66.6 mA |
44.4 mA |
40 mA |
16.7 mA |
12.5 mA |
| Coil resistance |
45 Ω |
101 Ω |
125 Ω |
720 Ω |
1,920 Ω |
| Coil inductance(H) (ref. value) |
Set |
Armature OFF |
0.05 |
0.12 |
0.14 |
0.60 |
1.98 |
| Armature ON |
0.03 |
0.074 |
0.088 |
0.41 |
1.23 |
| Reset |
Armature OFF |
0.03 |
0.082 |
0.098 |
0.46 |
1.34 |
| Armature ON |
0.06 |
0.14 |
0.16 |
0.54 |
2.23 |
| Must set voltage |
75% max. of rated voltage |
| Must reset voltage |
75% max. of rated voltage |
| Max. voltage |
170% of rated voltage at 23ºC, 130% at 85ºC |
140% of rated voltage at 23ºC, 110% at 70ºC |
| Power consumption |
Approx. 200 mW |
Approx. 300 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
|
Single-side Stable EN60950/EN41003 Approved Type
(G6S-2-Y, G6S-2F-Y, G6S-2G-Y)
| Rated voltage |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
40 mA |
16.7 mA |
9.6 mA |
| Coil resistance |
125 Ω |
720 Ω |
2,504 Ω |
| Must operate voltage |
75% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
170% of rated voltage at 23ºC, 130% at 85ºC |
170% of rated voltage at 23ºC, 110% at 70ºC |
| Power consumption |
Approx. 200 mW |
Approx. 230 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
|
Contact Ratings
| Load |
Resistive load (cosφ = 1) |
| Rated load |
0.5 A at 125 VAC; 2 A at 30 VDC |
| Contact material |
Ag (Au-clad) |
| Rated carry current |
2A |
| Max. switching voltage |
250 VAC, 220 VDC |
| Max. switching current |
2A |
| Max. switching capacity |
62.5 VA, 60 W |
| Failure rate (reference value) |
10 µA at 10 mVDC |
| Note: P level: λ60 = 0.1 × 10-6/operation |
|
Characteristics
| Contact resistance |
75 mΩ max. |
| Operating (set) time |
4 ms max. (mean value: approx. 2.5 ms; latching type: approx. 2 ms) |
| Release (reset) time |
4 ms max. (mean value: approx. 1.5 ms; latching type: approx. 2 ms) |
| Bounce time |
Operate: Approx. 0.5 ms Release: Approx. 0.5 ms Set/Reset: Approx. 0.5 ms |
| Max. operating frequency |
Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching)
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
500 VAC, 50/60 Hz for 1 min between set and reset coil (double-winding latching)
|
| Impulse withstand voltage |
2,500 V (2 ×10 µs) between coil and contacts
1,500 V (10×160 µs) between coil and contacts (double-winding latching)
2,500 V (2×10 µs) between contacts of different polarity
1,500 V (10×160 µs) between contacts of same polarity (conforms to FCC Part 68) |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude) |
| Malfunction: |
10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) |
|
| Shock resistance |
Destruction: 1,000 m/s2(approx. 100G) Malfunction: 750 m/s2(approx. 75G) |
| Endurance |
| Mechanical: |
100,000,000 operations min. (at 36,000 operations/hr) |
| Electrical: |
100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr) 100,000 operations min. (0.5 A at 125 VAC, resistive load) |
|
| Ambient temperature |
Operating: -40ºC to 85ºC (with no icing)
-40ºC to 70ºC (double-winding latching, 24 VDC) |
| Ambient humidity |
Operating: 5% to 85% |
| Weight |
Approx. 2 g |
|
| Note: |
All units are in millimeters unless otherwise indicated. |
Single-side Stable
G6S-2, G6S-2-Y
Tolerance of ±0.3
 |
Footprint
(Bottom VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
 |
G6S-2F, G6S-2F-Y
Tolerance of ±0.3
 |
Footprint
(Top VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(Top VIEW)
 |
G6S-2G , G6S-2G-Y
Tolerance of ±0.3
 |
Footprint
(Top VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(Top VIEW)
 |
Single-winding Latching
G6SU-2
Tolerance of ±0.3
 |
Footprint
(Bottom VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
 |
G6SU-2F
Tolerance of ±0.3
 |
Footprint
(Top VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(Top VIEW)
 |
G6SU-2G
Tolerance of ±0.3
 |
Footprint
(Top VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(Top VIEW)
 |
Double-winding Latching
G6SK-2
Tolerance of ±0.3
 |
Footprint
(Bottom VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
 |
G6SK-2F
Tolerance of ±0.3
 |
Footprint (TOP VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
G6SK-2G
Tolerance of ±0.3
 |
Footprint
(TOP VIEW) Tolerance:±0.1
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
|
Relays