Signal Relays
G6L Surface-mounting Relay
Extremely Thin SPST-NO Flat Relay, One of the Thinnest Relays in the World
- Dimensions of 7.0(W)×10.6(L) ×4.2 mm(H)(SMD) or 3.8 mm(H) (TH) represent a reduction of approximately 20% in mounting area and approximately 67% in volume compared with the OMRON G5V-1, for higher-density mounting.
- Ensures a dielectric strength between coil and contacts (1,000 VAC), and conforms to FCC Part 68 (i.e., withstanding an impulse withstand voltage of 1.5 kV for 10 x 160µs). High dielectric strength between contacts of same polarity (750 VAC).
- Surface-mounting relays are also available.
- Single-winding latching models to save energy.
- Conforms to UL60950 (File No. E41515) / CSA C22.2 No. 60950 (File No. LR31928).
- Use of lead completely eliminated.
 |
|
|
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
Single-side stable |
| SPST-NO |
Fully sealed |
Through-hole terminal
| G6L-1P |
| Surface-mounting terminal
| G6L-1F |
| Note: |
1. |
When ordering, add the rated coil voltage to the model number. |
| |
|
Example: G6L-1P |
 |
| |
2. |
When ordering tape packing, add "-TR" to the model number. |
| |
|
Example: G6L-1F |
 |
| |
|
Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case. |
Coil Ratings
Single-side Stable Relays (G6L-1P, G6L-1F)
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
60.0 mA |
40.0 mA |
36.0 mA |
15.0 mA |
9.6 mA |
| Coil resistance |
50.0 Ω |
112.5 Ω |
139.0 Ω |
800.0 Ω |
2,504.0 Ω |
| Must operate voltage |
75% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Maximum. voltage |
150% of rated voltage |
130% of rated voltage |
| Power consumption |
Approx. 180 mW |
Approx. 230 mW |
| NOTE: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
The operating characteristics are measured at a coil temperature of 23ºC. |
| |
3. |
The maximum voltage is the highest voltage that can be imposed on the relay coil. |
|
Contact Ratings
| |
Resistive load |
| Contact mechanism |
Single crossbar |
| Rated load |
0.3 A at 125 VAC; 1 A at 24 VDC |
| Rated carry current |
1A |
| Max. switching voltage |
125 VAC, 60 VDC |
| Max. switching current |
1A |
|
Characteristics
| Classification |
| Item |
Model |
|
Single-side Stable Relays |
| G6L-1P, G6L-1F
|
| Contact resistance (See note 1.) |
100 mΩ max. |
| Operating time (See note 2.) |
5 ms max. (approx. 1.1 ms) |
| Release time (See note 2.) |
5 ms max. (approx. 0.4 ms) |
| Insulation resistance (See note 3.) |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
Coil and contacts |
1,000 VAC, 50/60 Hz for 1 min |
| Contacts of same polarity |
750 VAC, 50/60 Hz for 1 min |
| Impulse withstand voltage |
Coil and contacts |
1,500 VAC, 10 x 160 µs |
| Vibration resistance |
Destruction |
10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) |
| Malfunction |
10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) |
| Shock resistance |
Destruction |
1,000 m/s2 |
| Malfunction |
100 m/s2 |
| Endurance |
Mechanical |
5,000,000 operations min. (at 36,000 operations/hour) |
| Electrical |
100,000 operations min. (with a rated load at 1,800 operations/hour) |
| Failure rate (P level) (See note 4.) |
1 mA at 5 VDC |
| Ambient temperature |
Operating : -40ºC to 70ºC (with no icing or condensation) |
| Ambient humidity |
Operating : 5% to 85% |
| Weight |
Approx. 0.6 g |
| NOTE: |
1. |
The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. |
| |
2. |
Values in parentheses are actual values. |
| |
3. |
The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking the dielectric strength. |
| |
4. |
This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions. |
| |
5. |
The above values are initial values. |
|
| Note: |
All units are in millimeters unless otherwise indicated. |
G6L-1P
 |
PCB Mounting Holes
(Bottom VIEW)
Tolerance:±0.1mm
 |
Terminal Arrangement/Internal Connections
(Bottom VIEW)
 |
| Note: |
Each value has a tolerance of Å}0.3 mm. |
|
G6L-1F
 |
PCB Mounting Dimensions
(TOP VIEW)
Tolerance:±0.1mm
 |
Terminal Arrangement/Internal Connections
(TOP VIEW)
 |
| Note: |
Each value has a tolerance of +0.3 mm. |
|