Signal Relays
G6K Surface-mounting Relay
Surface-mounting Relay with theWorld's Smallest Mounting Area and aHeight of Only 5.2 mm
- Subminiature model as small as 5.2 (H) × 6.5 (W) ×10 (L)mm is ideal for high-density mounting.
- Low profile of 5.2 mm and weight of only 0.7 g combine toimprove mounting efficiency.
- Models with inside-L surface-mounting terminals are available.
- Consumes approximately 70% the power of aconventional OMRON model and operates at a currentthat is as low as 100 mW.
- Surface-mounting terminal models incorporate a uniqueterminal structure with high infrared irradiation efficiencywhich allows the terminal temperature to rise easily when mounting the IRS, thus ensuring excellent soldering.
- Ensures a dielectric strength of 1,500 VAC and conformsto FCC Part 68 (i.e., withstanding an impulse withstandvoltage of 1,500 V for 10 ×160 µs).
- New-Y models offer an impulse withstand voltage of2,500 V for 2 × 10µs (conforms to Bellcorespecifications) by optimizing the distance between coil and contacts.
- Conforms to UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR24825)
The above specifications are ensured as of August 1999.
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Classification |
Single-side stable |
Single-winding latching |
Single-side stable Bellcore: 2, 500 V for 2x10µs |
| DPDT |
Plastic sealed |
Through-hole terminal |
G6K-2P |
G6KU-2P-Y |
G6K-2P-Y |
| Surface mount terminal |
Inside-L |
G6K-2G |
G6KU-2G-Y |
G6K-2G-Y |
| Outside-L |
G6K-2F |
G6KU-2F-Y |
G6K-2F-Y |
| Note: |
1. |
When ordering, add the rated coil voltage to the model number. |
| |
|
Example: G6L-1P |
 |
| |
2. |
When ordering tape packing, add "-TR" to the model number. |
| |
|
Example: G6L-1F |
 |
| |
|
Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case. |
Coil Ratings
Single-side Stable Models G6K-2F, G6K-2G , G6k-2P
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
| Rated current |
33.0 mA |
23.2 mA |
21.1 mA |
9.1 mA |
| Coil resistance |
91 Ω |
194 Ω |
237 Ω |
1,315 Ω |
| Must operate voltage |
80% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
150% of rated voltage at 23ºC to70ºC |
| Power consumption |
Approx. 100 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
The Operating characteristics are measured at a coil temperature of 23ºC. |
| |
3. |
The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. |
|
Single-side Stable Models (Bellcore Version)
G6K-2F-Y, G6K-2G-Y, G6K-2P-Y
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
33.0 mA |
23.2 mA |
21.1 mA |
9.1 mA |
4.6 mA |
| Coil resistance |
91 Ω |
194 Ω |
237 Ω |
1,315 Ω |
5,220 Ω |
| Must operate voltage |
80% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
150% of rated voltage at 23ºC to 70ºC |
| Power consumption |
Approx. 100 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
The Operating characteristics are measured at a coil temperature of 23ºC. |
| |
3. |
The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. |
Single-winding Latching Models (Bellcore Version)
G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
| Rated voltage |
3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
33.0 mA |
23.2 mA |
21.1 mA |
9.1 mA |
4.6 mA |
| Coil resistance |
91 Ω |
194 Ω |
237 Ω |
1,315 Ω |
5,220 Ω |
| Must set voltage |
75% max. of rated voltage |
| Must reset voltage |
75% max. of rated voltage |
| Max. voltage |
150% of rated voltage at 23ºC to 70ºC |
| Power consumption |
Approx. 100 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
The Operating characteristics are measured at a coil temperature of 23ºC. |
| |
3. |
The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. |
|
Contact Ratings
| Load |
Resistive load |
| Rated load |
0.3 A at 125 VAC; 1 A at 30 VDC |
| Rated carry current |
1A |
| Max. switching voltage |
125 VAC, 60 VDC |
| Max. switching current |
1A |
|
Characteristics
| Item |
Single-side stable models (double-pole) |
Single-winding latching model |
| G6K-2F, G6K-2G, G6K-2P |
G6K-2F-Y, G6K-2G-Y,G6K-2P-Y |
G6KU-2F-Y, G6KU-2G-Y,G6KU-2P-Y |
| Contact resistance (see note 1) |
100 mΩ max. |
| Operating (set) time (see note 2) |
3 ms max. (approx. 1.4 ms) |
3 ms max. (approx. 1.2 ms) |
| Release (reset) time (see note 2) |
3 ms max. (approx. 1.3 ms) |
3 ms max. (approx. 1.2 ms) |
| Insulation resistance (see note 3) |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
Coil and contacts |
1,500 VAC, 50/60 Hz for 1 min |
| Contacts of different polarity |
1,000 VAC, 50/60 Hz for 1 min |
| Contacts of same polarity |
750 VAC, 50/60 Hz for 1 min |
| Impulse withstand voltage |
Coil and contacts |
1,500 V, 10 × 160 µs |
2,500 V, 2 × 10 µs, 1,500 V, 10 x 160 µs |
| Contacts of different polarity |
1,500 V, 10 × 160 µs |
| Contacts of same polarity |
| Vibration resistance |
| Destruction: |
10 to 55 Hz, 5-mm double amplitude and 55 to 500 Hz, 300 m/s2 (approx. 30G) |
| Malfunction: |
10 to 55 Hz, 3.3-mm double amplitude and 55 to 500 Hz, 200 m/s2 (approx. 20G) |
|
| Shock resistance |
Destruction: 1,000 m/s2(approx. 100G) Malfunction: 750 m/s2(approx. 75G) |
| Life expectancy |
| Mechanical: |
50,000,000 operations min. (at 36,000 operations/hour) |
| Electrical: |
100,000 operations min. (with a rated load at 1,800 operations/hour) |
|
| Failure rate (P level) (see note 4) |
10 µA at 10 mVDC |
| Ambient temperature |
Operating: -40ºC to 70ºC (with no icing or condensation)
Storage: -40ºC to 70ºC (with no icing or condensation) |
| Ambient humidity |
Operating: 35 to 85% |
| Weight |
Approx. 0.7 g |
| Note: |
The above values are initial values. |
| Note: |
1. |
The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. |
| |
2. |
Values in parentheses are actual values. |
| |
3. |
The insulation resistance was measured with a 500-VDC megger applied to the same parts as those used for checking the dielectricstrength. |
| |
4. |
This value was measured at a switching frequency of 120 operations/min. |
|
| Note: |
All units are in millimeters unless otherwise indicated. |
DPDT
G6K-2F
 |
Mounting Dimensions
(TOP VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6K-2G
 |
Mounting Dimensions
(TOP VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6K-2P
 |
Mounting Dimensions
(Bottom VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6K-2F-Y
 |
Mounting Dimensions
(TOP VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6K-2G-Y
 |
Mounting Dimensions
(TOP VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6K-2P-Y
 |
Mounting Dimensions
(BOTTOM VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6KU-2F-Y
 |
Mounting Dimensions
(TOP VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6KU-2G-Y
 |
Mounting Dimensions
(TOP VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(TOP VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
G6KU-2P-Y
 |
Mounting Dimensions
(BOTTOM VIEW) Tolerance:±0.1mm
 |
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
 |
| Note: |
Each value has a tolerance of ±0.3mm |
|
|
Relays