Signal Relays
G6E PCB Relay
Subminiature, Sensitive SPDT Signal Switching Relayt
- High sensitivity: 98-mW pickup coil power.
- Impulse withstand voltage meets FCC Part 68 requirements.
- Fully sealed construction.
- Unique moving loop armature reduces relay size,
magnetic interference, and contact bounce time.
- Single- and double-winding latching types also available
 |
|
|
|
Updated March 23, 2009
|
This web page provides an excerpt from a datasheet. Refer to Datasheetand other applicable documents for more information.
| Contact form |
Terminal |
Single-side stable |
Single-winding latching |
Double-winding latching |
| SPDT |
Bifurcated crossbar |
Straight terminal |
G6E-134P-US |
G6EU-134P-US |
G6EK-134P-US |
Self-clinching terminal |
G6E-134C-US |
G6EU-134C-US |
G6EK-134C-US |
| Note: |
When ordering, add the rated coil voltage to the model number. |
| |
Example: G6E-134P-US |
 |
Coil Ratings
Single-side Stable, Bifurcated Crossbar Contact Type
| Rated voltage |
3 VDC |
5 VDC |
6 VDC |
9 VDC |
12 VDC |
24 VDC |
48 VDC |
| Rated current |
66.7 mA |
40 mA |
33.3 mA |
22.2 mA |
16.7 mA |
8.3 mA |
8.3 mA |
| Coil resistance |
45 Ω |
125 Ω |
180 Ω |
405 Ω |
720 Ω |
2,880 Ω |
5,760 Ω |
| Coil inductance (H) (ref. value) |
Armature OFF |
0.08 |
0.18 |
0.31 |
0.62 |
1.20 |
4.70 |
5.35 |
| Armature ON |
0.06 |
0.17 |
0.24 |
0.50 |
0.99 |
3.90 |
5.12 |
| Must operate voltage |
70% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
190% of rated voltage at 23ºC |
170% of rated voltageat 23ºC |
| Power consumption |
Approx. 200 mW |
Approx. 400 mW |
|
Single-winding Latching, Bifurcated Crossbar Contact Type
| Rated voltage |
3 VDC |
5 VDC |
6 VDC |
9 VDC |
12 VDC |
24 VDC |
| Rated current |
66.7 mA |
40 mA |
33.3 mA |
22.2 mA |
16.7 mA |
8.3 mA |
| Coil resistance |
45 Ω |
125 Ω |
180 Ω |
405 Ω |
720 Ω |
2,880 Ω |
Coil inductance (H) (ref. value) |
Armature OFF |
0.05 |
0.13 |
0.19 |
0.45 |
0.84 |
3.56 |
| Armature ON |
0.04 |
0.12 |
0.17 |
0.40 |
0.79 |
3.10 |
| Must set voltage |
70% max. of rated voltage |
| Must reset voltage |
70% max. of rated voltage |
| Max. voltage |
190% of rated voltage at 23ºC |
| Power consumption |
Approx. 200 mW |
|
Double-winding Latching, Bifurcated Crossbar Contact Type
| Rated voltage |
3 VDC |
5 VDC |
6 VDC |
9 VDC |
12 VDC |
24 VDC |
| Set coil |
Rated current |
66.7 mA |
40 mA |
33.3 mA |
22.2 mA |
16.7 mA |
8.3 mA |
| Coil resistance |
45 Ω |
125 Ω |
180 Ω |
405 Ω |
720 Ω |
2,880 Ω |
Coil inductance (H) (ref. value) |
Armature OFF |
0.03 |
0.09 |
0.12 |
0.25 |
0.44 |
1.66 |
| Armature ON |
0.03 |
0.08 |
0.11 |
0.22 |
0.41 |
1.62 |
| Reset coil |
Rated current |
66.7 mA |
40 mA |
33.3 mA |
22.2 mA |
16.7 mA |
8.3 mA |
| Coil resistance |
45 Ω |
125 Ω |
180 Ω |
405 Ω |
720 Ω |
2,880 Ω |
Coil inductance (H) (ref. value) |
Armature OFF |
0.03 |
0.09 |
0.12 |
0.25 |
0.44 |
1.66 |
| Armature ON |
0.03 |
0.08 |
0.11 |
0.22 |
0.41 |
1.62 |
| Must set voltage |
70% max. of rated voltage |
| Must reset voltage |
70% max. of rated voltage |
| Max. voltage |
190% of rated voltage at 23ºC |
| Power consumption |
Set coil:Approx. 200 mW Reset coil:Approx. 200 mW |
| Note: |
1. |
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
| |
2. |
Operating characteristics are measured at a coil temperature of 23ºC. |
|
Contact Ratings
| Load |
Resistive load (cosφ = 1) |
Inductive load (cosφ = 0.4) (L/R = 7 ms) |
| Rated load |
0.4 A at 125 VAC; 2 A at 30 VDC |
0.2 A at 125 VAC; 1 A at 30 VDC |
| Contact material |
Ag (Au-clad) |
| Rated carry current |
3A |
| Max. switching voltage |
250 VAC, 220 VDC |
| Max. switching current |
3A |
3A |
| Max. switching power |
50 VA, 60 W |
25 VA, 30 W |
Failure rate (reference value) |
10 µA at 10 mVDC |
Note: P level: λ60 = 0.1 × 10-6/operation
|
Characteristics
| Contact resistance |
50 mΩ max. |
| Operate (set*) time |
5 ms max. (mean value: approx. 2.9 ms; 48 VDC type: approx. 2.4 ms) |
| Release (reset*) time |
5 ms max. (mean value: approx. 1.3 ms) |
| Bounce time |
Operate: 3 ms max. (mean value: 0.37 ms) Release: 3 ms max. (mean value: 1.12 ms) |
| Max. operating frequency |
Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric withstand voltage |
1,500 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity |
| Impulse withstand voltage |
1,500 V (10 × 160 µs) (conforms to FCC Part 68) |
| Vibration resistance |
| Destruction: |
10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude) |
| Malfunction: |
10 to 55 to 10 Hz, 1.65-mm single amplitude
(3.3-mm double amplitude) |
|
| Shock resistance |
Destruction: 1,000 m/s2
Malfunction: 300 m/s2 |
| Endurance |
| Mechanical: |
100,000,000 operations min. (at 36,000 operations/hr) |
| Electrical: |
100,000 operations min. (0.4 A at 125 VAC resistive load;0.2 A at 125 VAC inductive load)
500,000 operations min. (2 A at 30 VDC resistive load;1 A at 30 VDC inductive load)
200,000 operations min. (3 A at 30 VDC resistive load) |
|
| Ambient temperature |
Operating: -40ºC to 70ºC (with no icing) |
| Ambient humidity |
5% to 85% |
| Weight |
Approx. 2.7 g |
*Minimum set and reset signals width is 7 ms min.
|
| Note: |
1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows: |
G6E-134P-US G6E-194P-US |
 |
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
 |
G6E-134C-US G6E-194C-US
|
 |
Mounting Holes (Bottom VIEW) Tolerance:±0.1mm  |
G6EU-134P-US G6EU-194P-US
|
 |
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
 |
G6EU-134C-US G6EU-194C-US
|
 |
Mounting Holes (Bottom VIEW) Tolerance:±0.1mm  |
G6EK-134P-US G6EK-194P-US
|
 |
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
 |
G6EK-134C-US G6EK-194C-US
|
 |
Mounting Holes (Bottom VIEW) Tolerance:±0.1mm  |
|
Relays
Product Lineup
Support
Related Links


|