G6E PCB Relay

Subminiature, Sensitive SPDT Signal Switching Relayt

  • High sensitivity: 98-mW pickup coil power.
  • Impulse withstand voltage meets FCC Part 68 requirements.
  • Fully sealed construction.
  • Unique moving loop armature reduces relay size,
    magnetic interference, and contact bounce time.
  • Single- and double-winding latching types also available
This web page provides an excerpt from a datasheet.
Refer to Datasheetand other applicable documents for more information.
OrderingInformationRatings / CharacteristicsDimensions
Contact form Terminal Single-side stable Single-winding latching Double-winding latching
SPDT Bifurcated
crossbar
Straight terminal G6E-134P-US G6EU-134P-US G6EK-134P-US
Self-clinching
terminal
G6E-134C-US G6EU-134C-US G6EK-134C-US
Note: When ordering, add the rated coil voltage to the model number.
  Example: G6E-134P-US
OrderingInformationRatings / CharacteristicsDimensions
Coil Ratings
Single-side Stable, Bifurcated Crossbar Contact Type
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA 8.3 mA
Coil resistance 45 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω 5,760 Ω
Coil inductance (H) (ref. value) Armature OFF 0.08 0.18 0.31 0.62 1.20 4.70 5.35
Armature ON 0.06 0.17 0.24 0.50 0.99 3.90 5.12
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 190% of rated voltage at 23ºC 170% of rated voltageat 23ºC
Power consumption Approx. 200 mW Approx. 400 mW

Single-winding Latching, Bifurcated Crossbar Contact Type
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC
Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
Coil resistance 45 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω
Coil inductance
(H) (ref. value)
Armature OFF 0.05 0.13 0.19 0.45 0.84 3.56
Armature ON 0.04 0.12 0.17 0.40 0.79 3.10
Must set voltage 70% max. of rated voltage
Must reset voltage 70% max. of rated voltage
Max. voltage 190% of rated voltage at 23ºC
Power consumption Approx. 200 mW

Double-winding Latching, Bifurcated Crossbar Contact Type
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC
Set coil Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
Coil resistance 45 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω
Coil inductance
(H) (ref. value)
Armature OFF 0.03 0.09 0.12 0.25 0.44 1.66
Armature ON 0.03 0.08 0.11 0.22 0.41 1.62
Reset coil Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
Coil resistance 45 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω
Coil inductance
(H) (ref. value)
Armature OFF 0.03 0.09 0.12 0.25 0.44 1.66
Armature ON 0.03 0.08 0.11 0.22 0.41 1.62
Must set voltage 70% max. of rated voltage
Must reset voltage 70% max. of rated voltage
Max. voltage 190% of rated voltage at 23ºC
Power consumption Set coil:Approx. 200 mW
Reset coil:Approx. 200 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
  2. Operating characteristics are measured at a coil temperature of 23ºC.


Contact Ratings
Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4)
(L/R = 7 ms)
Rated load 0.4 A at 125 VAC;
2 A at 30 VDC
0.2 A at 125 VAC;
1 A at 30 VDC
Contact material Ag (Au-clad)
Rated carry current 3A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 3A 3A
Max. switching power 50 VA, 60 W 25 VA, 30 W
Failure rate
(reference value)
10 µA at 10 mVDC
Note: P level: λ60 = 0.1 × 10-6/operation

Characteristics
Contact resistance 50 mΩ max.
Operate (set*) time 5 ms max. (mean value: approx. 2.9 ms; 48 VDC type: approx. 2.4 ms)
Release (reset*) time 5 ms max. (mean value: approx. 1.3 ms)
Bounce time Operate: 3 ms max. (mean value: 0.37 ms)
Release: 3 ms max. (mean value: 1.12 ms)
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric withstand voltage 1,500 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 1,500 V (10 × 160 µs) (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude
(5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude
(3.3-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 300 m/s2
Endurance
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (0.4 A at 125 VAC resistive load;0.2 A at 125 VAC inductive load)
500,000 operations min. (2 A at 30 VDC resistive load;1 A at 30 VDC inductive load)
200,000 operations min. (3 A at 30 VDC resistive load)
Ambient temperature Operating: -40ºC to 70ºC (with no icing)
Ambient humidity 5% to 85%
Weight Approx. 2.7 g
*Minimum set and reset signals width is 7 ms min.
OrderingInformationRatings / CharacteristicsDimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:


G6E-134P-US
G6E-194P-US

G6E:Dimensions1 Terminal Arrangement/
Internal Connections

(Bottom VIEW)
G6E:Dimensions2
G6E-134C-US
G6E-194C-US

G6E:Dimensions4 Mounting Holes
(Bottom VIEW)
Tolerance:±0.1mm

G6E:Dimensions6
G6EU-134P-US
G6EU-194P-US

G6E:Dimensions7 Terminal Arrangement/
Internal Connections

(Bottom VIEW)
G6E:Dimensions8
G6EU-134C-US
G6EU-194C-US

G6E:Dimensions10 Mounting Holes
(Bottom VIEW)
Tolerance:±0.1mm

G6E:Dimensions12
G6EK-134P-US
G6EK-194P-US

G6E:Dimensions13 Terminal Arrangement/
Internal Connections

(Bottom VIEW)
G6E:Dimensions14
G6EK-134C-US
G6EK-194C-US

G6E:Dimensions16 Mounting Holes
(Bottom VIEW)
Tolerance:±0.1mm

G6E:Dimensions18
Related Links
Technology
Application Guide